Publications by authors named "Rainer Hintsche"

A new approach for the detection of virulence factors of Staphylococcus aureus and Staphylococcus epidermidis using an electrical protein array chip technology is presented. The procedure is based on an enzyme-linked sandwich immunoassay, which includes recognition and binding of virulence factors by specific capture and detection antibodies. Detection of antibody-bound virulence factors is achieved by measuring the electrical current generated by redox recycling of an enzymatically released substance.

View Article and Find Full Text PDF

For the sensitive detection of amplicons derived from diagnostic PCR, a novel electrical low-density microarray is applied and compared to state-of-the-art quantitative real-time PCR. The principle of the electrochemical method and the effective use for analysis are described. Interdigitated array gold electrodes (IDA-E) embedded into a silicon chip are the core technology of the fully automated compact biosensor system, basing on enzyme coupled electrochemical detection.

View Article and Find Full Text PDF

Low-density electrical 16S rRNA specific oligonucleotide microarrays and an automated analysis system have been developed for the identification and quantitation of pathogens. The pathogens are Escherichia coli, Pseudomonas aeruginosa, Enterococcus faecalis, Staphylococcus aureus, and Staphylococcus epidermidis, which are typically involved in urinary tract infections. Interdigitated gold array electrodes (IDA-electrodes), which have structures in the nanometer range, have been used for very sensitive analysis.

View Article and Find Full Text PDF

For a diabetes mellitus patient, tight control of glucose level is essential. Results are reported of an investigation of the suitability of existing wearable continuous insulin infusors controlled and adjusted by a control algorithm using continuous glucose measurements as input to perform the functionality of an artificial pancreas. Special attention was given to the development of a continuous glucose monitor and to evaluate which quality of input data is necessary for the control algorithm.

View Article and Find Full Text PDF

BACKGROUND: Bacillus cereus constitutes a significant cause of acute food poisoning in humans. Despite the recent development of different detection methods, new effective control measures and better diagnostic tools are required for quick and reliable detection of pathogenic micro-organisms. Thus, the objective of this study was to determine a simple method for rapid identification of enterotoxic Bacillus strains.

View Article and Find Full Text PDF

A fully electrical array for voltammetric detection of redox molecules produced by enzyme-labeled affinity binding complexes is shown. The electronic detection is based on ultramicroelectrode arrays manufactured in silicon technology. The 200-microm circular array positions have 800-nm-wide interdigitated gold ultramicroelectrodes embedded in silicon dioxide.

View Article and Find Full Text PDF

Based on electrical biochips made in Si-technology cost effective portable devices have been constructed for field applications and point of care diagnosis. These miniaturized amperometric biosensor devices enable the evaluation of biomolecular interactions by measuring the redox recycling of ELISA products, as well as the electrical monitoring of metabolites. The highly sensitive redox recycling is facilitated by interdigitated ultramicroelectrodes of high spatial resolution.

View Article and Find Full Text PDF