Ear keloids are challenging lesions to treat due to high recurrence rates postexcision. Conservative compression techniques as adjunct treatment have been reported to be effective. An innovative technique of using computer-aided design/computed-aided manufacturing to print a customized auricular splint improves efficiency and comfort level for patients compared with conventional methods.
View Article and Find Full Text PDFPurpose: To study the effect of implant angulation on 3D linear and absolute angular distortions of implant analogs in printed resin models and conventional stone casts.
Materials And Methods: Three sectional master models with two implants with total inter-implant angulations of 0°, 10°, and 20° were fabricated. For each master model, five conventional stone casts (CS) and printed resin models (PM) were fabricated (n = 5).
Purpose: To study the effect of implant analog system, print orientation, and analog holder radial offset on 3D linear and absolute angular distortions of implant analogs in 3D printed resin models.
Materials And Methods: A sectional master model simulating a 2-implant, 3-unit fixed prosthesis in a partially edentulous jaw was fabricated. Three implant analog systems for 3D printed resin models-Straumann (ST), Core3DCentres (CD) and Medentika (MD)-were tested.