Publications by authors named "Raghavendra Holla"

Quantitative retrospective analysis of the normal lung irradiation due to the variations of the ITV volume based on the techniques used for upper lobe (UL), mid lobe (ML), and lower lobe (LL) lung tumours when used with 2-view, 1-view, 0-view based LOT technique on Cyberknife, AveIP on Helical Tomotherapy, and DIBH on VMAT systems. In the treatment of lung tumours, patients medically inoperable or those who are unwilling to undergo surgery have the option to be treated using radiation therapy. There are many motion control techniques available for the treatment of the moving target, such as movement encompassment, respiratory gating, breath-hold, motion reduction, and tumour monitoring.

View Article and Find Full Text PDF

Background: This is a prospective study evaluating the role of stereotactic body radiotherapy (SBRT) with CyberKnife (CK) in Indian patients suffering from hepatocellular carcinoma with portal vein thrombosis (HCC-PVT).

Methods: Patients with inoperable HCC-PVT, good performance score (PS), and liver function are accrued for treatment on CK (version M6) and planned with Multiplan (iDMS V2.0).

View Article and Find Full Text PDF

Background: The advances in image guidance and capability of highly conformal dose deliveries made possible the use of helical tomotherapy (HT) for lung cancer treatment. To determine the effect of respiratory motion on the delivered dose in HT, film dosimetry using a dynamic phantom was performed. This was a phantom study to determine the effect of motion on the delivered dose in HT.

View Article and Find Full Text PDF

The aim of this study was to design and fabricate a thorax phantom to quantify the radiation doses to the region of the chest wall (with 3 ionization chambers), the organ at risk (OAR) (lung), and the surface using radiochromic films (EBT3) for three different 3D CRT treatment planning techniques. Anthropomorphic phantoms are one of the best tools for verifying the quality of the radiotherapy treatment plans generated by treatment planning systems since they can provide equivalent human tissue densities. Thirty acrylic plates were cut into ellipses 21 cm in height and 31 cm in width, and slots were created to insert lung equivalent cork material and bone equivalent Teflon material.

View Article and Find Full Text PDF

Background: Evaluate morbidities and "quality" of fiducial marker placement in primary liver tumours (hepatocellular carcinoma [HCC]) for CyberKnife.

Materials And Methods: Thirty-six HCC with portal vein thrombosis(PVT) were evaluated for "quality" of fiducial placement, placement time, pain score, complications, recovery time and factors influencing placement.

Results: One hundred eight fiducials were placed in 36 patients.

View Article and Find Full Text PDF

Objectives: Motivation of this study is to check the sensitivity of dosimetric tool gamma with 2D detector array combination when unexpected errors occur while transferring intensity-modulated radiation therapy treatment plans from planning system to treatment unit.

Methods: This study consists of 17 head and neck cancer patient's treatment plans. Nine types of verification plans are created for all 17 clinically approved treatment plans by consecutively deleting different segments (up to eight) one by one from each field of the plan.

View Article and Find Full Text PDF

Purpose: An experimental method using the linear portion of the relative film dose-response curve for radiographic and radiochromic films is presented, which can be used to determine the relative depth doses in a variety of very small, medium, and large radiation fields and relative output factors (ROFs) for small fields.

Materials And Methods: The film slope (FS) method was successfully applied to obtain the percentage depth doses (PDDs) for external beams of photon and electrons from a Synergy linear accelerator (Elekta AB, Stockholm, Sweden) under reference conditions of 10 cm × 10 cm for photon beam and nominal 10 cm × 10 cm size applicator for electron beam. For small-field dosimetry, the FS method was applied to EDR2 films (Carestream Health, Rochester, NY) for 6 MV photon beam from a linac (Elekta AB, Stockholm, Sweden) and small, circular radiosurgery cones (Elekta AB, Stockholm, Sweden) with diameters of 5, 7.

View Article and Find Full Text PDF

Aims And Objectives: The influence of target motion on the reconstructed internal target volume (ITV) for device-based (DB) external surrogate system and Smart deviceless (DL) 4-dimensional (4D) system were compared in a controlled phantom experiment. The volumetric changes in reconstructed ITVs from the average intensity projection (AveIP) images using DB method (Anzai Respiratory Gating System, ANZAI MEDICAL CO., LTD, Japan) and DL method (Smart deviceless 4D system by GE Medical Systems (Chicago, USA)) with the theoretical true volume (ITV) for moving target with the increasing target motion in anterior-posterior (A-P), lateral (left-right [L-R]) and inferior-superior (S-I) directions were assessed.

View Article and Find Full Text PDF

Background: Breast cancer tissue is sensitive to hypofractionation. This is an analysis of patients treated with hypofractionated protocols since 2009, at our tertiary cancer center.

Methods: Details of breast cancer patients treated with adjuvant hypofractionated external beam radiation therapy (EBRT) from January 2009 to December 2014 were retrieved and analyzed.

View Article and Find Full Text PDF

Purpose: A prospective study was undertaken to evaluate the influence of patient positioning on the set up variations to determine the planning target volume (PTV) margins and to evaluate the clinical relevance volume assessment of the small bowel (SB) within the irradiated volume.

Materials And Methods: During the period of months from December 2011 to April 2012, a computed tomography (CT) scan was done either in supine position or in prone position using a belly board (BB) for 20 consecutive patients. All the patients had histologically proven rectal cancer and received either post- or pre-operative pelvic irradiation.

View Article and Find Full Text PDF

Aim: To compare and evaluate the performance of two different volumetric modulated arc therapy delivery techniques.

Background: Volumetric modulated arc therapy is a novel technique that has recently been made available for clinical use. Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc for different treatment sites.

View Article and Find Full Text PDF