Background: This in vitro study investigated whether full-guided (FG) or half-guided (HG) implant placement is more suitable for beginners and to what extent the use of the coDiagnostiX (CDX) (10.5, Straumann Group, Basel, Switzerland) implant planning software proves useful in teaching.
Methods: Twenty students planned implant positions with CDX which were then placed in a model using printed drill templates in the sense of FG implantation (group 1) and HG implantation (group 2).
Background: Postoperative resorption of hard and soft tissues occurs as a consequence of tooth extraction. The Benex-Control extractor allows minimally invasive extraction of the tooth without causing pronounced iatrogenic trauma. The aim of this study was to verify whether the resorption of the tissues after extraction can be reduced by using the Benex system compared to the conventional extraction method.
View Article and Find Full Text PDFDental materials are challenged by wear processes in the oral environment and should be evaluated in laboratory tests prior to clinical use. Many laboratory wear-testing devices are high-cost investments and not available for cross-centre comparisons. The 'Rub&Roll' wear machine enables controlled application of force, chemical and mechanical loading, but the initial design was not able to test against rigid antagonist materials.
View Article and Find Full Text PDFStress distribution and its magnitude during loading heavily influence the osseointegration of dental implants. Currently, no high-resolution, three-dimensional method of directly measuring these biomechanical processes in the peri-implant bone is available. The aim of this study was to measure the influence of different implant materials on stress distribution in the peri-implant bone.
View Article and Find Full Text PDFThe marginal accuracy of fit between prosthetic restorations and abutment teeth represents an essential aspect with regard to long-term clinical success. Since the final gap is also influenced by the luting techniques and materials applied, this study analyzed the accuracy of the fit of single-tooth zirconia copings before and after cementation using different luting materials. Forty plaster dies with a corresponding zirconia coping were manufactured based on a single tooth chamfer preparation.
View Article and Find Full Text PDFThe implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies.
View Article and Find Full Text PDFIntroduction: This study aimed to determine whether implant surgery procedures can be implemented in the dental curriculum by designing novel courses for students. Additionally, this study assesses the perception of these courses and how they can be established in the future.
Materials And Methods: Students from the third to fifth years participated in a programme consisting of 4 modules according to their academic year.
Objectives: Artefacts from dental implants in three-dimensional (3D) imaging may lead to incorrect representation of anatomical dimensions and impede virtual planning in navigated implantology. The aim of this study was quantitative assessment of artefacts in 3D STL models from cone beam CT (CBCT) and multislice CT (MSCT) using different scanning protocols and titanium-zirconium (Ti-Zr) and zirconium (ZrO) implant materials.
Methods: Three ZrO and three Ti-Zr implants were respectively placed in the mandibles of two fresh human specimens.
Objective: In dental restorations, color determination is very important for achieving esthetic results. The aim of this study was to compare visual shade selection using digital methods and to assess the repeatability of the utilized intraoral scanners.
Materials And Methods: In 31 probands, tooth color was determined on teeth 11, 13, and 16.
Purpose: To evaluate intraoral scanners, scannable impression materials, and conventional methods for impression-taking with regard to precision and accuracy.
Materials And Methods: Ten impressions per technique were initially taken from a cobalt-chromium (Co-Cr) master model (chamfer preparation for the maxillary right first molar) for fabricating Co-Cr crown copings. The test specimens, their respective metal master model, and the plaster casts from the conventional impressions were then digitized with the light-optical Atos Triple Scanner.
The aim of this study was to compare the trueness of complete- and partial-arch impressions obtained using conventional impression materials and intraoral scanners in vivo. Full-arch impressions were taken using polyether and polyvinylsiloxane. Gypsum casts were digitized using a laboratory scanner (IM, AF).
View Article and Find Full Text PDFBackground: In mucogingival and implant surgery, an autologous soft tissue graft from the palate is the gold standard for reconstructing missing keratinised soft tissue and volume. Previously, presurgical measurements of the graft harvesting site were described with two-dimensional (2D) linear measurements. The present observational clinical study aimed to evaluate a three-dimensional (3D) measurement method for determining the present palatal soft tissue volume for each patient individually.
View Article and Find Full Text PDFBackground: With the constantly increasing demand for metal-free solutions in dental therapy, numerous ceramic restorations have found their way into everyday clinical practice, but long-term clinical data are limited.
Objective: The aim of this prospective clinical study was to evaluate three- and four-unit fixed partial dentures in the posterior region made of zirconium dioxide frameworks veneered with feldspathic porcelain after 10 years in clinical use.
Methods: Based on the two studies published in 2009 and 2012, in which the all-ceramic FDPs were evaluated after 3 and 5 years of function, a clinical evaluation of a total of 17 restorations after 10 years with regard to their condition and long-term stability was carried out in the course of this study.
Statement Of Problem: Compared with the frequent investigations into the accuracy of digital intraoral scans, studies analyzing digital determinations of jaw relationships based on intraoral scans are scarce.
Purpose: The purpose of this in vitro study was to present an optical 3-dimensional method for analyzing deviations in static occlusion and to compare the accuracy of conventional and digital interocclusal registrations.
Material And Methods: A Frasaco jaw model was duplicated, articulated, and scanned with a high-precision industrial scanner, and the data were stored in a virtual standard tessellation language (STL) format, which served as the reference model.
Background: The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years.
Methods: The abrasion behavior of 15 bridge constructions from 15 different participants was examined after a period of 3, 5, and 10 years using plaster models, which were then subjected to a scanning process on the Atos II industrial scanner and digitized for three-dimensional evaluation of the abrasion by the corresponding software (ATOS Professional 7.
Objectives: This study's hypothesis was to evaluate differences of the occlusal wear rate for monolithically fabricated lithium disilicate and hand-veneered zirconia crowns in-vivo. Furthermore, a comparison of the materials' clinical performance according to CDA criteria was investigated.
Methods: A total number of 15 patients in the need of full-coverage ceramic fixed dental prosthesis on molars were treated with two crowns each (n = 30), randomly assigned on the contralateral sides made of monolithic IPS e.
Purpose: Sufficient data are not currently available on how the various geometries of scan bodies and different scan strategies affect the quality of digital impressions of implants. The purpose of this study was to present new data on these two topics and give clinicians a basis for decision making.
Materials And Methods: A titanium master model containing three Nobelreplace Select™ implants (Nobelbiocare Services AG, Zurich, Switzerland) was digitized using an ATOS industrial noncontact scanner.
For horizontal bone deficiency alveolar ridge osteotomy is considered an option for augmentation. Major advantages are the option for a one-stage approach and the absence of donor site morbidity. However, the conventional technique is associated with complications such as perforations and fractures of the cortical bone.
View Article and Find Full Text PDFAim: Deformation of the mandible presents a major challenge for many dentists, both in conventional prosthetic supraconstructions and in complex implant restorations. This study aimed to evaluate the three-dimensional (3D) deformation of the mandible in vivo with scannable impression material and an industrial optical scanner.
Materials And Methods: In the present study, 20 female and 20 male subjects were examined.
Purpose: Three-dimensional (3D) radiological imaging plays an important role in surgical planning used in modern dentistry. The aim of this study was to optimize imaging parameters with a special focus on voxel size and scan time.
Material And Methods: A virtual 3D master model of a macerated human skull was generated using an industrial optical noncontact white light scanner.
Objective: Low pH neutralization and subsequent remnant hydrophilicity can lead to hygroscopic expansion of self-adhesive resin cements (SARCs) after water storage. The aim of this in vitro study was to investigate the effects of hygroscopic expansion of SARCs, used as luting and partial core build-up material, on integrity and cement gap thickness increase of all-ceramic CAD/CAM crowns.
Methods: Human third molars (n=48) were prepared and anatomical all-ceramic CAD/CAM crowns were manufactured (VITABLOCS Mark II, VITA Zahnfabrik).
Purpose: Advanced imaging modalities, such as multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT), greatly facilitate diagnostic medicine. In radiological research, it is important to know how accurately a scanned object is visualized, and whether the methodology leads to image distortion. The objective of this study was to evaluate whether formalin fixation impacted the accuracy of virtual 3D bone models generated via CBCT and MSCT using a software-based evaluation method that excluded human measurement errors.
View Article and Find Full Text PDFPurpose: The use of a surgical template is a well-established method in advanced implantology. In addition to conventional fabrication, computer-aided design and computer-aided manufacturing (CAD/CAM) work-flow provides an opportunity to engineer implant drilling templates via a three-dimensional printer. In order to transfer the virtual planning to the oral situation, a highly accurate surgical guide is needed.
View Article and Find Full Text PDF