Objective: This study evaluated the influence of tooth shade, resin-based luting agent shade values, and ceramic thickness on the optical properties of CLVs.
Materials And Methods: The study involved 16 participants who received 95 CLVs. CIE L*, a*, b* color coordinates were assessed with a clinical spectrophotometer.
Objectives: This study investigated altmetrics, citations, and field-normalized impact of dental articles reporting randomized clinical trials (RCTs) published within a one-year period.
Methods: Data were collected in 2024 from PubMed-indexed RCTs published in 2019. Dependent variables included Altmetric Attention Scores (AAS), PlumX citations, and Field-Weighted Citation Impact (FWCI).
J Mech Behav Biomed Mater
September 2024
This study assessed the monotonic and fatigue flexural strength (FS), elastic modulus (E), and surface characteristics of a 3D printed zirconia-containing resin composite compared to subtractive and conventional layering methods. Specimens, including discs (n = 15; Ø = 15 mm × 1.2 mm) and bars (n = 15; 14 × 4 × 1.
View Article and Find Full Text PDFObjectives: To assess the growth of a multispecies biofilm on root canal dentin under different radiotherapy regimens.
Materials And Methods: Sixty-three human root dentin cylinders were distributed into six groups. In three groups, no biofilm was formed (n = 3): NoRT) non-irradiated dentin; RT55) 55 Gy; and RT70) 70 Gy.
This study assessed the mechanical properties and surface characteristics of dental prosthetic acrylic resin fabricated by 3D printing, comparing it with subtractive, pressing, and molding techniques. Bar-shaped specimens (N= 90; 65 × 10 × 3.3 mm; ISO:207951) were prepared and assigned into six groups: PRINT (3D printing vis stereolithography with PriZma 3D Bio Denture, Makertech Labs); SUB (subtractive manufacturing with Vipiblock Trilux, Vipi); PRESS Base (pressing using muffle with Thermo Vipi Wave, Vipi for base); PRESS Tooth (pressing with Onda-cryl, Clássico for tooth); MOLD Base (molding using addition silicone with Vipi Flash, Vipi for base); and MOLD Tooth (molding with Dencor, Clássico for tooth).
View Article and Find Full Text PDFIn this study, poly (lactic-co-glycolic acid) (PLGA) microparticles loaded with cannabidiol (CBD) were synthesized (PLGA@CBD microparticles) and embedded up to 10 wt% in a chondroitin sulfate/polyvinyl alcohol hydrogel matrix. In vitro chemical, physical, and biological assays were carried out to validate the potential use of the modified hydrogels as biomaterials. The microparticles had spherical morphology and a narrow range of size distribution.
View Article and Find Full Text PDFThis in vitro study assessed the effectiveness of three cleaning protocols (air-water spray, 37% phosphoric acid, or Ivoclean) on lithium disilicate restorations' fatigue behavior after try-in paste application, compared to a clean condition. Lithium disilicate discs (IPS e.max CAD, Ivoclar) with Ø-= 12 mm and 1 mm thickness were prepared from prefabricated CAD-CAM blocks, polished, subjected to CAD-CAM milling topography simulation and crystallization.
View Article and Find Full Text PDFObjectives: This study evaluated the impact of different solvents and UV post-curing times on properties of 3D printing resins for provisional restorations.
Methods: The post-processing methods were tested using two solvents (isopropyl alcohol or absolute ethanol) and three UV times (5, 10, or 30 min). The resins tested were Resilab 3D Temp, Printax Temp, and Prizma Bioprov.
Purpose: This study aimed to assess the bonding stability of three universal adhesives to a CAD-CAM feldspathic ceramic with or without prior silane application.
Materials And Methods: The universal adhesives tested were Ambar Universal (FGM), Single Bond Universal (3M), and Ybond Universal (Yller). Scotchbond Multipurpose Plus (3M) was used as a control.
To evaluate color differences (ΔE) and translucency parameters (TP) from mono, bi, and trilayer resin composite veneers using different opacities and shades of resin composite over lighter and darker simulated tooth-colored substrates. Mono, bi, and trilayer veneers (1.5 mm) (n = 12) were made using two shades (A1 and A2) and three opacities (enamel, body, and dentin) of resin composite over simulated lighter (A1) and darker (C4, and C4+) tooth-colored substrates.
View Article and Find Full Text PDFThis study analyzed the prevalence of lectures involving esthetics in the scientific program of Brazilian dental conferences and the gender distribution of speakers. All lectures presented in three dental conferences (Bahia, São Paulo, and Goiás states) held from 2016 to 2020 were evaluated. Three investigators individually divided the lectures according to the specialties recognized by the Brazilian Federal Council of Dentistry (FCD) based on their titles.
View Article and Find Full Text PDFStatement Of Problem: After the use of evaluation paste, residue can remain on the bonding surface. However, how adhesion to lithium disilicate ceramic is affected is unclear.
Purpose: The purpose of this in vitro study was to determine the effectiveness of lithium disilicate cleaning after contamination with an evaluation paste and before the application of a resin cement.
This study aims to report analyses regarding the global distribution of institutions involved in clinical trials of COVID-19 vaccines throughout February 2022. We retrieved global data from the World Health Organization report on vaccine development. These data allowed us to identify project institutions and plot their geographic coordinates.
View Article and Find Full Text PDFResin composites are the most versatile restorative materials used in dentistry and the first choice for restoring posterior teeth. This article reviews aspects that influence the clinical performance of composite restorations and addresses clinically relevant issues regarding different direct techniques for restoring posterior teeth that could be performed in varied clinical situations. The article discusses the results of long-term clinical trials with resin composites and the materials available in the market for posterior restorations.
View Article and Find Full Text PDFObjectives: This review study provides an overview of factors that influence the longevity of all types of direct resin composite restorations.
Methods: A systematic search was performed in PubMed, Scopus, and Web of Science databases for articles reporting data from primary longitudinal clinical studies on composite longevity published 2011-2021. Prospective or retrospective studies with restorations in permanent dentition, with follow-up periods of at least 5 years were included.
This was a retrospective cohort study to investigate the impact of COVID-19 pandemic on the gender gap in articles submitted to three international dental journals based in Brazil. All submissions performed to Brazilian Dental Journal, Brazilian Oral Research, and Journal of Applied Oral Science before (2019) and during the pandemic (2020) were assessed. Gender of the first, last, and corresponding authors were collected.
View Article and Find Full Text PDFCannabidiol (CBD) has been gaining increased attention in contemporary society but seems to have been little explored in dentistry. This scoping review mapped the scientific and technological scenarios related to the use of CBD in dentistry. Peer-reviewed publications were searched in five international databases, patents were searched in five technological platforms.
View Article and Find Full Text PDFObjectives: To evaluate the incorporation of repairing capsules containing different monomers and polymerization modulators on the self-healing efficiency of an experimental photopolymerizable resin-based composite.
Methods: Self-healing capsules containing different monomers and polymerization modulators were prepared by emulsion polymerization: TC (TEGDMA and DHEPT), BTC (Bis-GMA, TEGDMA, and DHEPT), and BTC (Bis-GMA, TEGDMA, and BPO). The capsules were analyzed through Fourier transform infrared spectroscopy and scanning electron microscopy.
Objective: This cross-sectional study with dentists in Brazil assessed the COVID-19 incidence and severity, its vaccination status, and the level of confidence in vaccines in May 2021 (COVID-19 second wave). The medications used to prevent or treat COVID-19, including controversial substances (vitamin D, ivermectin, zinc, and chloroquine), were analyzed.
Methodology: Dentists were recruited by email and responded to a pretested questionnaire until May 31, 2021.
Objectives: Deterioration in anterior resin composite restorations placed in tooth wear patients was investigated after 36 months.
Materials And Methods: Data collected prospectively for 47 participants of the Radboud Tooth Wear Project were used (41 ± 8 years, 90% male, n = 270 restorations). Restorations were individually evaluated using intraoral photographs and 3D scans to rate modified FDI scores and to record the presence of degradation features.
This study investigated the effect of ultrasound application when luting ceramic using two preheated composites that show distinct responses to preheating at 69°C: Filtek Z100 and Z350XT. RelyX Veneer was the control. Feldspar disks were luted using the resin-based luting agents (RBLAs), and ultrasound was tested.
View Article and Find Full Text PDFBackground: The COVID-19 pandemic has significantly influenced the routine of healthcare workers. This study investigated the impact of the pandemic on dental practice and dentists' feelings in Latin America.
Methods: A survey was conducted with dentists from 11 Spanish-speaking Latin American countries in September-December 2020.
Purpose: This study investigated the ability of two chewing simulation devices to emulate in vitro the clinical deterioration observed in anterior composite restorations in severe tooth-wear patients.
Materials And Methods: Advanced tooth wear was simulated in bovine incisors, which were restored with palatal and buccal direct composite veneer restorations. The incisal edges of restorations were subjected to 960K cycles of either compressive loading (Biocycle-V2; 125 N at 2 Hz) or wear and mechanical loading (Rub and Roll; 30 N at 20 rpm).
Objectives: This retrospective study evaluated the performance of posterior composites after up to 33 years of clinical service and investigated factors associated with the risk of failures over time including patient- and tooth-related variables.
Methods: Patients who received at least one Class I or Class II direct composite restoration in a private office in 1986-1992 and had follow-up appointments were included. Failures and interventions over time were investigated using the dental records.