Publications by authors named "Rafael Perez-Cambrodi"

Purpose: To evaluate changes in angle κ after the implantation of a trifocal intraocular lens (IOL) and to assess the postoperative outcomes of patients with different angle κ values.

Setting: IOA Madrid Innova Ocular, Madrid, Spain.

Design: Prospective trial.

View Article and Find Full Text PDF

Purpose: To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures.

Methods: This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. In all cases, 3 repeated measures of corneal topography and ocular aberrometry were performed with the iDesign 2 system (iD2; Johnson & Johnson Vision Care Inc, Jacksonville, FL) and one keratometric measurement was performed with the intraocular lens-(IOL) Master 500 (Carl Zeiss Meditec Inc, Dublin, CA) and Sirius (CSO) (SIR) systems.

View Article and Find Full Text PDF

Aim: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles.

Methods: A total of 40 eyes of 40 patients with a mean age of 34.1y were included.

View Article and Find Full Text PDF

To review binocular and accommodative disorders documented after corneal or intraocular refractive surgery, in normal healthy prepresbyopic patients. A bibliographic revision was performed; it included works published before 1st July 2017 where accommodation and/or binocularity was assessed following any type of refractive surgical procedure. The search in Pubmed yielded 1273 papers, 95 of which fulfilled the inclusion criteria.

View Article and Find Full Text PDF

Purpose: To evaluate the differences in corneo-scleral topographic profile between healthy and keratoconus eyes, and their potential diagnostic ability for keratoconus detection.

Methods: Prospective comparative study including 21 keratoconic eyes (11 patients) and 88 healthy eyes (88 patients). In all cases, a complete eye exam was performed including an evaluation of the corneo-scleral profile.

View Article and Find Full Text PDF

Purpose: To determine the usefulness of a silicone-hydrogel bandage contact lens (BCL) in the immediate postoperative period after uneventful myopic laser in-situ keratomileusis (LASIK).

Methods: The study design was randomized but not masked and data collection was prospective. This study comprised 51 consecutive myopic eyes intervened by means of the LASIK technique to compensate their refractive error.

View Article and Find Full Text PDF

Microperimetry (MP) is a technology that allows the study of retinal sensitivity at different foveal and parafoveal areas as well as eye fixation. It is a technique of functional evaluation, providing a direct correlation between anatomical and functional outcomes. There are a great variety of studies which evaluate the repeatability or reliability of measurements obtained with this technology and also describe and explore different clinical applications.

View Article and Find Full Text PDF

Purpose: To compare central corneal backscatter obtained from Scheimpflug images between patients with insulin-dependent and non-insulin-dependent diabetes mellitus (IDDM and NIDDM, respectively) and healthy controls.

Methods: Seven patients with IDDM (7 eyes), eleven patients with NIDDM (11 eyes), and sixteen healthy subjects (16 eyes) were included in this pilot study. Scheimpflug imaging system (Pentacam, Oculus Inc.

View Article and Find Full Text PDF

This study evaluated the clinical outcomes in keratoconus corneas following accelerated transepithelial corneal collagen cross-linking (CXL) (Avedro KXL system, Waltham, MA, USA) over one year of follow-up. The mean depth of the demarcation line measured by optical coherence tomography (OCT) was 205.19 µm.

View Article and Find Full Text PDF

Purpose: To establish normative values of retinal sensitivity and parameters describing the fixation pattern using macular analyzer integrity assessment (MAIA) microperimetry (Centervue, Padova, Italy) in adults and children.

Methods: A sample of 237 eyes of 237 healthy subjects aged between 10 and 70 years (mean age 30.63 ± 16.

View Article and Find Full Text PDF

Soft multifocal simultaneous image contact lenses have boomed in recent years due to the growing number of presbyopic patients demanding visual solutions, allowing them to maintain their current standard of living. The concept of 'simultaneous image' is based on blur interpretation and/or blur tolerance of superimposed multiple images on the retina formed by various powers of a contact lens. This is the basis for a specific type of multifocal contact lens developed for the compensation of presbyopia.

View Article and Find Full Text PDF

Fundus autofluorescence (FAF) is a noninvasive imaging method to detect fundus endogenous fluorophores, mainly lipofuscin located in the retinal pigment epithelium (RPE). The FAF provides information about lipofuscin distribution and RPE health, and consequently an increased accumulation of lipofuscin has been correlated with ageing and development of certain retinal conditions. Areas covered: An exhaustive literature search in MEDLINE (via OVID) and PUBMED for articles related to ocular FAF in retinal diseases and different devices used for acquiring FAF imaging was conducted.

View Article and Find Full Text PDF

Diabetes mellitus is a metabolic disease with a considerable impact on healthcare owing to its increased prevalence and high mortality rate. Structural, morphological, and physiological changes in each of the ocular components have been described in detail. Autofluorescence has been described as a good indicator of metabolic activity.

View Article and Find Full Text PDF

Purpose. Evaluate optimized fundus autofluorescence (FAF) imaging in early stages of diabetic retinopathy (DR) and relate findings with conventional colour fundus imaging and visual function in diabetic patients and control subjects. Materials and Methods.

View Article and Find Full Text PDF

Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus.

Design: Prospective study.

Participants: Fifteen eyes of 8 subjects (age, 12-80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included.

View Article and Find Full Text PDF

Purpose. To validate clinically a new method for estimating the corneal power (P c ) using a variable keratometric index (n kadj) in eyes with previous laser refractive surgery. Setting.

View Article and Find Full Text PDF

Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses.

Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision).

View Article and Find Full Text PDF

The dislocation of the crystalline lens or couching technique was the predominant procedure to surgically remove cataracts until the 18th century A.D. However, in the Middle Ages, some Arab physicians tried to aspirate the opaque lens by means of a glass tube following a paracentesis.

View Article and Find Full Text PDF

Purpose: We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas.

Methods: This study comprised a total of 43 keratoconic eyes (27 patients, 17-73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11-54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15-64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode.

Methods: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the Costruzione Strumenti Oftalmici [CSO] Sirius system.

View Article and Find Full Text PDF

Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP).

Materials And Methods: Clinical data from 25 eyes of 14 patients (age range, 52-77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (P(IOLadj)) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (n(kadj)) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELP(adj)).

View Article and Find Full Text PDF

Aim: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP).

Methods: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis.

View Article and Find Full Text PDF

Purpose: To evaluate the reliability and intersession agreement of measurements of retinal sensitivity as well as of the fixation pattern obtained in healthy eyes with a microperimeter integrating the mechanism of the scanning laser ophthalmoscope (SLO) with the static perimetry.

Methods: This study included a sample of 44 healthy eyes of 44 subjects of a mean age of 27.0 ± 8.

View Article and Find Full Text PDF