Statement Of Problem: Thiourethane has high chemical affinity with polymeric materials and its addition has been suggested for improving adhesives and composite resin. However, a systematic review of thiourethane addition is lacking.
Purpose: The purpose of this systematic review was to analyze the articles in the dental literature that studied the effect of thiourethane added to the resin matrix of dental materials related to polymerization shrinkage and mechanical properties.
This study verified the effect of the combination of preheated hydrofluoric acid/silane/electric current in the adhesion of the resin cement to ceramic. IPS E.max Press ceramic discs embedded in PVC rigid tubes were divided into four groups associating preheated hydrofluoric acid and silane applied with electrical current (n=10): Ha+S (Heated acid + silane); Ha+S+Ec (Heated acid + silane + electrical current); A+S (Acid + silane) and A+S+Ec (Acid + silano + electrical current).
View Article and Find Full Text PDFThis study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.
View Article and Find Full Text PDFThis study evaluated the dental displacement in dentures included in different flasks and processed by the Australian cycle modified or by microwave. Metal pins were placed on the teeth as reference for measurements: a) Incisal edge of maxillary and mandibular central incisors, buccal cusp of maxillary and mandibular vestibular first premolars, and mesiobuccal maxillary and mandibular cusps of second molars; b) Incisor to incisor, premolar to premolar and molar to molar; c) Left incisor to left molar and right incisor to right molar, and d) Vertical. Dentures were divided according to flasks (n=10): G1- Metal; G2- HH bimaxillary metal; G3-Microwaves; G4- HH bimaxillary microwaves.
View Article and Find Full Text PDFPurpose: The aim of this study was to evaluate the adhesive bond strength of fiberglass posts treated with experimental silanes based on thio-urethane and submitted to thermo and mechanical cycles.
Materials And Methods: Bovine roots were divided into six groups: RX-RU2 (RelyX CP + RelyX U200); PETMP-HDDI-RU2 (PETMP-HDDI + RelyX U200); PETMP-BDI-RU2 (PETMP-BDI + RelyX U200); RX-RU (RelyX CP + RelyX Ultimate); PETMP-HDDI-RU (PETMP-HDDI + RelyX Ultimate); PETMP-BDI-RU (PETMP-BDI + RelyX Ultimate). One slice from each root third (n=10) was submitted to the push-out test and the values evaluated with R Program statistical analysis, while the failure pattern assessed in percentage.
Int J Oral Maxillofac Implants
December 2020
Purpose: The aim of this study was to inspect the mechanical fatigue behavior of an implant-supported restorative system using polyether ether ketone (PEEK) and yttria partially stabilized zirconia polycrystals (YZ) as materials for customized definitive implant-supported hybrid abutments, supporting two types of all-ceramic restorations: translucent zirconia (TZ) and lithium disilicate (LD) monolithic crowns.
Materials And Methods: Forty Morse taper implants were included in epoxy resin. Titanium intermediary abutments were placed, and the specimens were randomly allocated into four groups (n = 10) according to the customized hybrid abutment material (PEEK or YZ) and the monolithic crowns (TZ or LD) representing a maxillary central incisor crown.
Thiourethane additives have been shown to improve properties in several dental polymer applications. The aim of this study was to verify the effect of the addition of thiourethane oligomers and acrylamide or isobornyl-based plasticizers on the physical properties of the denture base acrylic resin polymerized with microwaves. Thiourethane oligomer (TU) was synthetized and added to microwaved acrylic resin in proportions varying between 3 and 14 wt%.
View Article and Find Full Text PDFThe aim of this study was to verify the effect of the implant volume loss, vertical misfit between abutment and prosthetic platform, prosthetic screw loosening torque, and screw stress distribution in titanium and zirconia abutments. Ten CAD/CAM system custom abutments of each material were milled and attached to the titanium implants. The implant volume loss was evaluated by microtomography, the vertical misfit with optical microscopy, and digital torque wrench measured the prosthetic screw loosening.
View Article and Find Full Text PDFSeverely resorbed mandibles with only cortical bone remaining can fracture during or after implant placement. This case series presents a technique to reduce the risk or the consequences of mandibular fracture. Seven patients with only cortical mandibular bone remaining were treated with the fixation of a titanium plate in the frontal surface previously to implant placement, during the same surgical procedure.
View Article and Find Full Text PDFThe aim of this study was to evaluate the influence of the coefficient of thermal expansion (CTE or α) and glass transition temperature (Tg) of three veneering ceramics used with zirconia frameworks of full-arch fixed prostheses. The generation of residual stresses and linear contraction after the simulation of the cooling process and mechanical loading were measured. The analysis was based on the finite element method in three-dimensional model of a maxillary full-arch fixed prosthesis with zirconia framework (e.
View Article and Find Full Text PDFThe aim of this study was to evaluate by three-dimensional finite element analysis (3D-FEA) the biomechanics involved in bar-framework system for overdentures. The studied factors were latero-lateral angulation in the right implant (-10, -5, 0, 5 and 10 degrees), and different bar cross-sections (circular, Hader and oval) presenting horizontal misfits (50 or 150 µm) on the opposite implant. Positive angulation (5 and 10 degrees) for implant inclination to mesial position, negative angulation (-5 and -10 degrees) for distal position, and zero degree for parallel implants.
View Article and Find Full Text PDFThis in vitro study investigated the role of welding techniques of implant-supported prostheses in the 2D and 3D marginal misfits of prosthetic frameworks, strain induced on the mini abutment, and detorque of prosthetic screws. The correlations between the analyzed variables were also investigated. Frameworks were cast in commercially pure titanium (cp-Ti).
View Article and Find Full Text PDFThe study verified the bond strength in simulated dental restorations of silorane- or methacrylate-based composites repaired with methacrylate-based composite. Methacrylate- (P60) or silorane-based (P90) composites were used associated with adhesive (Adper Single Bond 2). Twenty-four hemi-hourglass-shaped samples were repaired with each composite (n=12).
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
December 2016
We evaluated two treatment concepts for the rehabilitation of moderate atrophic maxilla with dental implants (all-on-four and all-on-six) and the effect of framework material on the stress distribution of implant-support system. A three-dimensional finite element model based on a prototype was built to simulate an entirely edentulous maxilla with moderate sinus pneumatization that was rehabilitated with a full-arch fixed dental prosthesis. Four standard implants were positioned according to the all-on-four concept and four standard implants and two short implants were placed according to the all-on-six concept.
View Article and Find Full Text PDFThe aim of this study was to evaluate the microhardness and surface roughness of composite resins immersed in alcoholic beverages. Three composite resins were used: Durafill (Heraeus Kulzer), Z250 (3M-ESPE) and Z350 XT (3M-ESPE). The inital surface roughness and microhardness were measured.
View Article and Find Full Text PDFThe aim of this study was to evaluate the conventional and boiled polymerization cycles on gloss, roughness, hardness and impact strength of acrylic resins. Samples were made for each Classico and QC-20 materials (n=10) in dental stone molds obtained from rectangular metallic matrices embedded in metallic flasks. The powder-liquid ratio and manipulation of the acrylic resins' were accomplished according to manufacturers' instructions and the resins were conventionally packed in metallic flasks.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
May 2016
The influence of casting and masticatory simulation on marginal misfit and strain in multiple implant-supported prostheses was evaluated. Three-unit screw retained fixed dental prosthesis (FDP) and screw retained full-arch fixed dental prosthesis (FAFDP) frameworks were made using calcinable or overcasted cylinders on conical dental implant abutment. Four groups were obtained according to the cylinder and prosthesis type (n=10).
View Article and Find Full Text PDFAim: The purpose of this study was to determine the effect of different solutions cola soft drink (CSD) and coffee on roughness and microleakage of composite resin restorations.
Materials And Methods: Sixty bovine incisors were prepared and restored using Filtek Z350 XT (3M/ESPE) nanoparticulate resin. The samples were divided into three groups (n = 20): A (control)-Immersion in artificial saliva (14 days); B: Immersion in coffee (14 days), for 15 minutes (3x/day) and C: Immersion in CSD for 14 days (3x/day).
J Prosthodont
August 2016
Purpose: The aim of the study was to evaluate the effect of a prosthetic cylinder and casting on the misfit and loosening torque of screw-retained multiple-unit implant-supported dental prostheses under masticatory simulation.
Materials And Methods: Screw-retained, three-unit fixed dental prostheses (FDP) and screw-retained full-arch FDP frameworks were waxed using calcinable (plastic cylinders) or overcasted (premachined cast-on cylinders) on the dental implant abutments. The cylinders were cast in Co-Cr alloy to obtain four groups according to cylinder type and prosthesis type (n = 10).
Int J Oral Maxillofac Implants
April 2016
Purpose: The aim of this study was to evaluate the axial tightening force applied by conventional and diamondlike carbon (DLC)-coated screws and to verify, through three-dimensional finite element analysis (FEA), the stress distribution caused by different framework materials and prosthetic screws in overdenture frameworks with different misfit levels.
Materials And Methods: The axial tightening force applied by the screw was evaluated by means of a titanium matrix connected to a load cell. Conventional titanium or DLC-coated screws were tightened with a digital torque wrench, and the load values were recorded.
Purpose: The aim of this study was to evaluate the tensile bond strength (TBS) of repairs in recent fillings of methacrylate- (MBC) or silorane-based composites (SBC) subsequent to different surface treatments.
Materials And Methods: Fifty slabs of Filtek P60 (3M ESPE, St Paul, USA) and Filtek P90 (3M ESPE) were stored for 10 days in distilled water at 37°C. The surface of adhesion was abraded with a 600-grit silicone paper and repaired using each respective composite: G1, no treatment (control); G2, application of adhesive; G3, application of silane and adhesive; G4, sandblasting (Al2O3) and adhesive; and G5, sandblasting (Al2O3), silane, and adhesive.
Objective: Evaluate the stress distribution on the peri-implant bone tissue and prosthetic components of bar-clip retaining systems for overdentures presenting different implant inclinations, vertical misfit and framework material.
Materials And Methods: Three-dimensional models of a jaw and an overdenture retained by two implants and a bar-clip attachment were modeled using specific software (SolidWorks 2010). The studied variables were: latero-lateral inclination of one implant (-10°, -5°, 0°, +5°, +10°); vertical misfit on the other implant (50, 100, 200 µm); and framework material (Au type IV, Ag-Pd, Ti cp, Co-Cr).
Unlabelled: Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven.
Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket.
Eur J Dent
October 2014
Objective: To evaluate the surface roughness of acrylic resin submitted to chemical disinfection via 1% sodium hypochlorite (NaClO) or 1% peracetic acid (C2H4O3).
Materials And Methods: The disc-shaped resin specimens (30 mm diameter ×4 mm height) were polymerized by heated water using two cycles (short cycle: 1 h at 74°C and 30 min at 100°C; conventional long cycle: 9 h at 74°C). The release of substances by these specimens in water solution was also quantified.
Energy dispersive X-ray spectroscopy microanalysis (EDX), scanning electron microscopy (SEM), and Archimedes' Principle were used to determine the characteristics of inorganic filler particles in five dental alginates, including Cavex ColorChange (C), Hydrogum 5 (H5), Hydrogum (H), Orthoprint (O), and Jeltrate Plus (JP). The different alginate powders (0.5 mg) were fixed on plastic stubs (n = 5) and sputter coated with carbon for EDX analysis, then coated with gold, and observed using SEM.
View Article and Find Full Text PDF