Publications by authors named "Rafael Arrans"

Purpose: To report the clinical implementation of a novel external beam radiotherapy technique for accelerated partial breast irradiation treatments based on combined electron and photon modulated beams radiotherapy (MERT+IMRT) with conventional MLC.

Materials And Methods: A group of patients was selected to test the viability of the technique. The prescribed dose was 38.

View Article and Find Full Text PDF

The purpose of this study was to present a Monte-Carlo (MC)-based optimization procedure to improve conventional treatment plans for accelerated partial breast irradiation (APBI) using modulated electron beams alone or combined with modulated photon beams, to be delivered by a single collimation device, i.e. a photon multi-leaf collimator (xMLC) already installed in a standard hospital.

View Article and Find Full Text PDF

The purpose of this paper is to assess the feasibility of delivering intensity- and energy-modulated electron radiation treatment (MERT) by a photon multileaf collimator (xMLC) and to evaluate the improvements obtained in shallow head and neck (HN) tumors. Four HN patient cases covering different clinical situations were planned by MERT, which used an in-house treatment planning system that utilized Monte Carlo dose calculation. The cases included one oronasal, two parotid and one middle ear tumors.

View Article and Find Full Text PDF

Purpose: To date no detector can offer the unbeatable characteristics of film dosimetry in terms of spatial resolution and this is why it has been chosen by many institutions for treatment verification and, in that respect, radiochromic films are becoming increasingly popular due to their advantageous properties. It is the aim of this work to suggest an easy method to overcome one of the drawbacks in radiochromic film dosimetry associated with the scanning device, namely, the nonuniform dose dependent response, mainly due to the light scattering effect.

Methods: The suggested procedure consists of building four correction matrices by sequentially scanning one, two, three, and four unexposed blank films.

View Article and Find Full Text PDF

Background And Purpose: To evaluate the feasibility of using a photon MLC (xMLC) for modulated electron radiotherapy treatment (MERT) as an alternative to conventional post-mastectomy chest wall (CW) irradiation. A Monte Carlo (MC) based planning system was developed to overcome the inaccuracy of the 'pencil beam' algorithm. MC techniques are known to accurately calculate the dose distributions of electron beams, allowing the explicit simulation of electron interactions within the MLC.

View Article and Find Full Text PDF

Background And Purpose: The purpose of this work was a comparison of realistic IMRT plans based on the same CT-image data set and a common predefined set of dose objectives for the planning target volume and the organs at risk. This work was part of the larger European QUASIMODO IMRT verification project.

Materials And Methods: Eleven IMRT plans were produced by nine different European groups, each applying a representative set of clinically used IMRT treatment planning systems.

View Article and Find Full Text PDF

Background And Purpose: Absolute dose measurements for Intensity Modulated Radiotherapy (IMRT) beamlets is difficult due to the lack of lateral electron equilibrium. Recently we found that the absolute dosimetry in the penumbra region of the IMRT beamlet, can suffer from significant errors (Capote et al., Med Phys 31 (2004) 2416-2422).

View Article and Find Full Text PDF

This work presents an improvement to an algorithm for analytical beam weighting optimization where a flexible objective function, which considers 'importance factors' for each anatomical region and 'allowed deviations' from the prescribed dose, is defined. This upgrading allows forcing the mean value of the dose distribution to be the desired value, by using Lagrange multipliers. A real case is presented to show the effect of this change.

View Article and Find Full Text PDF

Intensity modulated radiotherapy (IMRT) has become a treatment of choice in many oncological institutions. Small fields or beamlets with sizes of 1 to 5 cm2 are now routinely used in IMRT delivery. Therefore small ionization chambers (IC) with sensitive volumes 0.

View Article and Find Full Text PDF

Intensity modulated radiation therapy (IMRT) has evolved toward the use of many small radiation fields, or "beamlets," to increase the resolution of the intensity map. The size of smaller beamlets can be typically about 1-5 cm2. Therefore small ionization chambers (IC) with sensitive volumes < or = 0.

View Article and Find Full Text PDF

Purpose: The influence of the multileaf collimator (MLC) leaf width on the dose distribution in patients treated with conformal radiotherapy and intensity-modulated radiotherapy has been analyzed. This study was based on the Monte Carlo simulation with the beams generated by a linac with the double-focused MLC.

Materials And Methods: The transmission through the leaves and the exact shape of the penumbra regions are difficult to model by treatment planning system algorithms.

View Article and Find Full Text PDF

Background And Purpose: A method for analytically solving the optimization of beam weighting in radiotherapy treatments using beam segmentation is presented.

Patients And Methods: A technique has been elaborated permitting the optimization of a flexible objective function which is defined by considering 'importance factors' for each anatomical region and 'allowed deviations' from the prescribed dose. As any change in these importance factors may lead to very different solutions, a statistical tool has been developed which varies the objective function automatically and iteratively to get the best possible results compatible with the chosen class solution.

View Article and Find Full Text PDF

Total skin electron therapy (TSET) is a complex technique which requires non-standard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm2 electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated.

View Article and Find Full Text PDF

An accurate determination of the penumbra of radiosurgery profiles is critical to avoid complications in organs at risk adjacent to the tumor. Conventional detectors may not be accurate enough for small field sizes. The Monte Carlo (MC) method was used to study the behavior of radiosurgical beam profiles at the penumbral region; the BEAM code was also used in this work.

View Article and Find Full Text PDF

Purpose: A tool to simulate complete intensity-modulated radiation therapy (IMRT) treatments with the Monte Carlo (MC) method has been developed. This application is based on a distribution model to employ as short processing times as possible for an operative verification.

Materials And Methods: The Clinical Primus-Siemens Linac beam was simulated with MC, using the EGS4 OMEGA-BEAM code package.

View Article and Find Full Text PDF