Publications by authors named "Rafael A Delgado Ruiz"

This review addresses the effects of various decontamination methods on the wettability of titanium and zirconia dental implants. Despite extensive research on surface wettability, there is still a significant gap in understanding how different decontamination techniques impact the inherent wettability of these surfaces. Although the literature presents inconsistent findings on the efficacy of decontamination methods such as lasers, air-polishing, UV light, and chemical treatments, the reviewed studies suggest that decontamination alters in vitro hydrophilicity.

View Article and Find Full Text PDF

A straightforward, laser-assisted method of extracting the metal housings from an overdenture by using the visible (blue) light of a high-power dental diode laser is presented. This approach produced localized softening of the acrylic resin, allowing the metal housing to be dislodged without damage. This technique minimizes damage to the metal housings during removal, is rapid and conservative, and may help reduce patient costs.

View Article and Find Full Text PDF

Mucous membrane pemphigoid (MMP) is an autoimmune condition characterized by subepithelial separation and deposition of autoantibodies and complement along the basement membrane zone. The disease results in the development of vesiculobullous lesions of the mucous membranes and skin. This report discusses the surgical treatment and management and the prosthetic implant rehabilitation of a patient with mucous membrane pemphigoid.

View Article and Find Full Text PDF

The stability of the implant-abutment interface is crucial for the maintenance of the implant index integrity. Several factors are capable of inducing deformation in implant-abutment connection, such as the actual insertion of the implant into the bone. This study aimed to evaluate the deformations produced in the connection after the insertion of the implant.

View Article and Find Full Text PDF

Background: There are no studies that have assessed the implant stability quotient (ISQ) values of narrow diameter implants placed in artificial dense bone blocks at varying drilling speeds (DSs).

Purpose: The aim of the present in vitro experiment was to compare the performance of OSSTELL and Penguin devices to evaluate implant stability at DSs of 800 and 2000 rpm.

Materials And Methods: A total of 360 osteotomies were created in dense artificial bone blocks at DSs of 800 and 2000 rpm.

View Article and Find Full Text PDF

The occlusal forces and their influence on the initiation of peri-implant bone loss or their relationship with peri-implantitis have created discussion during the past 30 years given the discrepancies observed in clinical, animal, and finite element analysis studies. Beyond these contradictions, in the case of an osseointegrated implant, the occlusal forces can influence the implant-bone interface and the cells responsible for the bone remodeling in different ways that may result in the maintenance or loss of the osseointegration. This comprehensive review focuses on the information available about the forces transmitted through the implant-crown system to the implant-bone interface and the mechano-transduction phenomena responsible for the bone cells' behavior and their interactions.

View Article and Find Full Text PDF

The aim of this experimental animal study was to assess guided bone regeneration (GBR) and implant stability (ISQ) around two dental implants with different macrogeometries. Forty eight dental implants were placed within six Beagle dogs. The implants were divided into two groups ( = 24 per group): G1 group implants presented semi-conical macrogeometry, a low apical self-tapping portion, and an external hexagonal connection (whereby the cervical portion was bigger than the implant body).

View Article and Find Full Text PDF

It is hypothesized that there is no statistically significant impact of drilling speed (DS) on the primary stability (PS) of narrow-diameter implants (NDIs) with varying thread designs placed in dense and soft simulated bone. The aim of this in vitro study was to evaluate the impact of DS on the PS of NDIs with varying thread designs placed in dense and soft simulated bone. Two hundred and forty osteotomies for placement of various implant macro-designs were divided into three groups (80 implants per group): Group A (NobelActive, 3.

View Article and Find Full Text PDF

Haemorrhagic disorders combined with soft tissue inflammation and infection may lead to severe bleeding complications before, during or after dental treatment. In selected cases, a combined therapeutic approach involving clinical therapies and systemic and local medication could improve the treatment outcomes and the patient's quality of life. This clinical case report, presents for the first time a successful combined approach, completed in a 38-year-old male patient with severe type-B haemophilia in which an infected tooth was extracted, an immediate implant was inserted, bone grafting was performed and early implant loading was successfully applied.

View Article and Find Full Text PDF

: The objective of this study was to evaluate new bone formation derived from freshly crushed extracted teeth, grafted immediately in post-extraction sites in an animal model, compared with sites without graft filling, evaluated at 30 and 90 days. : The bilateral premolars P2, P3, P4 and the first mandibular molar were extracted atraumatically from six Beagle dogs. The clean, dry teeth were ground immediately using the Smart Dentin Grinder.

View Article and Find Full Text PDF

Objectives: To investigate freshly extracted dental particulate used to graft post-extraction sockets in dogs, comparing new bone formation at experimental and control sites.

Materials And Methods: Bilateral premolars P2, P3, P4 and first mandibular molars were extracted atraumatically from six American Fox Hound dogs. The teeth were ground immediately using a 'Smart Dentin Grinder'.

View Article and Find Full Text PDF

The aim of this study was to evaluate the soft tissue thickness and marginal bone loss around dental implants with sloped micro-threaded shoulder (30° angle) in comparing with conventional design, inserted 30° degrees angulated in post extraction sockets and immediate loaded with temporary prosthesis simulating the all-on-four protocol. Six fox hound dogs received forty-eight post extraction dental implants with the different diameter and length (Medentika, Germany), but with different neck configurations. Two group of implants were inserted 1mm subcrestal [corrected].

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the misfit of three different implant-abutment connections before and after cycling load.

Materials And Methods: One hundred twenty dental implants and correspondent prefabricated titanium abutments were used. Three different implant-abutment connections were evaluated: Morse taper (MT group), external hexagon (EH group), and internal hexagon (IH group).

View Article and Find Full Text PDF

The impact of the laser tip on implant temperature when irradiating implants with lasers to treat peri-implantitis has received little attention. The present study was designed to assess the influence of two laser tips (sapphire chisel [MC3] and radial firing perio [RFP]) on temperature change of an implant irradiated with an Er,Cr:YSGG laser in vitro under various operational conditions. The results suggest that Er,Cr:YSGG irradiation using either tip with supplemental cooling can be a thermally safe approach to implant decontamination.

View Article and Find Full Text PDF

Objectives: To measure the lateral surface area of microgrooved zirconia implants, to evaluate the cell geometry and cell density of human fetal osteoblasts seeded on zirconia microgrooved implants, to describe the surface roughness and chemistry, and to evaluate the activity of human fetal osteoblasts seeded on zirconia microgrooved disks.

Materials And Methods: This experimental in vitro study used 62 zirconia implants and 130 zirconia disks. Two experimental groups were created for the implants: 31 non-microgrooved implants (Control) and 31 microgrooved implants (Test); two experimental groups were created for the disks: 65 non-microgrooved disks (Control) and 65 microgrooved disks (Test).

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate a new design of the cervical portion of dental implant with the objective to increase the volume of peri-implant tissues in the crestal area.

Materials And Methods: Forty-eight tapered dental titanium implants with internal conical connection were implanted in healed alveolar sites of six dogs. Twenty-four conventional implants design (C1 implant) formed the control group, and 24 new implant design (V3 implant) formed the test group.

View Article and Find Full Text PDF

Statement Of Problem: Esthetic factors influence the decision to use titanium or zirconia abutments in anterior regions. Clinicians may have concerns about the durability and behavior of these zirconia abutments.

Purpose: The purpose of this in vitro study was to evaluate the longitudinal and transverse long axes of the implant-abutment interface before and after the cyclic loading of titanium and zirconia abutments with an external hexagon.

View Article and Find Full Text PDF