Compared with the conventional magnetic resonance imaging (MRI), dedicated MRI scanners are more accessible. Images of a dedicated 1.0-T MRI specifically developed for the hand and wrist were compared with images of a conventional 1.
View Article and Find Full Text PDFBackground: In a prospective cohort study, the authors followed 112 women whose Poly Implant Prothèse silicone breast implants were recalled. Magnetic resonance imaging results and clinical consequences were previously published. The authors compared magnetic resonance imaging screening with explantation results to study the diagnostic value of magnetic resonance imaging in this unique unselected and nonbiased group.
View Article and Find Full Text PDFThe objective of this study is to investigate the prevalence of Andersson lesions (AL) in ankylosing spondylitis (AS) patients who will start anti-tumor necrosis factor (TNF) treatment. Radiographs and magnetic resonance imaging (MRI) of the spine were performed before therapy with anti-TNF. ALs were defined as discovertebral endplate destructions on MRI, associated with bone marrow edema and fat replacement or sclerosis, a decreased signal on T1, enhancement after contrast administration (gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA)), and increased signal on T2 and short tau inversion recovery (STIR).
View Article and Find Full Text PDFThe purpose of this study was to determine the feasibility of dynamic contrast-enhanced perfusion CT (CTP) in evaluating the hemodynamic response of tumors in the chest and abdomen treated with a combination of AZD2171 and gefitinib. Thirteen patients were examined just before and every 4-6 weeks after starting therapy. Following intravenous injection of a contrast agent, dynamic image acquisition was obtained at the level of a selected tumor location.
View Article and Find Full Text PDFBackground: The MRISC study is a screening study, in which women with an increased risk of hereditary breast cancer are screened by a yearly mammography and MRI, and half-yearly clinical breast examination. The sensitivity found in this study was 40% for mammography and 71% for MRI and the specificity was 95 and 90%, respectively. In the current subsequent study we investigated whether these results are influenced by age, a BRCA1/2 mutation, menopausal status and breast density.
View Article and Find Full Text PDFBackground: Within the Dutch MRI Screening (MRISC) study, a Dutch multicenter screening study for hereditary breast cancer, the authors investigated whether previously reported increased diagnostic accuracy of magnetic resonance imaging (MRI) compared with mammography would be maintained during subsequent screening rounds.
Methods: From November 1999 to October 2003, 1909 eligible women were included in the study. Screening parameters and tumor characteristics of different rounds were calculated and compared.
Clin Endocrinol (Oxf)
September 2005
Objective: GH-deficient adults have changes in body composition, bone mineral density (BMD) and lipid profile that can be altered by GH substitution. However, long-term data on GH substitution (up to 10 years of follow-up) are limited.
Design: The effects of 10 years of GH replacement therapy on BMD, body composition, bone parameters, serum lipids and glucose metabolism were studied.
Background: The value of regular surveillance for breast cancer in women with a genetic or familial predisposition to breast cancer is currently unproven. We compared the efficacy of magnetic resonance imaging (MRI) with that of mammography for screening in this group of high-risk women.
Methods: Women who had a cumulative lifetime risk of breast cancer of 15 percent or more were screened every six months with a clinical breast examination and once a year by mammography and MRI, with independent readings.
Purpose: Idiopathic spontaneous pneumothorax (SP) is the result of leakage of air from the lung parenchyma through a ruptured visceral pleura into the pleural cavity. This rupture is thought to be caused by an increased pressure difference between parenchymal airspace and pleural cavity. We hypothesize that rather peripheral airway inflammation leads to obstruction with check valve phenomena and by that to airtrapping in the lung parenchyma, which precedes spontaneous pneumothorax.
View Article and Find Full Text PDFBetween-center variation in bone densitometry may influence the frequency of the diagnosis of osteoporosis. To evaluate this problem, dual-energy X-ray absorptiometry (DXA) machines of the medical centers in the northwest of The Netherlands were evaluated. Four phantoms were used to test the 17 DXA machines of 16 participating centers.
View Article and Find Full Text PDFPurpose: To evaluate stent-graft and aneurysm wall motions during the cardiac cycle using cine magnetic resonance imaging (MRI) to identify mechanisms of long-term failure of endovascular aneurysm repair (EVAR).
Methods: Prior to and after EVAR in 7 patients with abdominal aortic aneurysms (AAA), 12 MRI images per cardiac cycle were acquired in transverse, sagittal, and coronal planes of the aneurysm. Two independent observers blinded to the aim of the study manually traced stent-graft and aneurysm wall contours.
Background: High-resolution computed tomography (HRCT) attenuation measurements may be more sensitive in finding early emphysematous changes in relatively young subjects than lung function measurements.
Objectives: To define lung attenuation parameters in smokers and never-smokers.
Methods: A prospective comparative study in a university hospital setting was designed with 20 healthy smoking and 20 nonsmoking volunteers.
In this study the interobserver reliability of three established measurement methods to objectify secondary deformities of the shoulder in obstetric brachial plexus lesion was evaluated (OBPL). Magnet resonance imaging scans of 30 affected shoulders of 29 OBPL children, mean age 1 year 9 months (range 3 months to 6.3 years) were used.
View Article and Find Full Text PDFMassive haemorrhage in ulcerative colitis mainly occurs as a result of exacerbated disease, usually acute or even fulminant colitis. Emergency proctocolectomy is currently advocated as the only reliable treatment of this patient group. However, this type of surgical intervention has a high rate of morbidity and mortality.
View Article and Find Full Text PDFThe objective of this study was to assess patency of the internal jugular vein following modified radical or selective neck dissection and microvascular flap reconstruction by power Doppler ultrasound and its impact on free flap survival. In 23 patients who underwent selective or modified radical neck dissection and microvascular flap reconstruction the patency of the internal jugular vein was examined by power Doppler ultrasound on the first post-operative day and after follow-up of at least four months. On the first post-operative day in one patient partial thrombosis was found, while in the other 22 patients the internal jugular vein was normal patent.
View Article and Find Full Text PDFPurpose: To report the endovascular treatment of a relatively uncommon entity: an aortic type B dissection combined with an aberrant subclavian artery (SA).
Case Report: A 59-year-old patient was admitted with chest pain and interscapular back pain. A transesophageal ultrasound and magnetic resonance angiography revealed a type B aortic dissection originating at the level of an aberrant SA orifice.
Our goal was to describe the MR findings of subcutaneously injected silicone in male-to-female transsexuals and to determine the most optimal combination of pulse sequences for discrimination of injected silicone from the surrounding structures. Seven male-to-female transsexuals were referred for MRI in order to detect the injected silicone in the subcutaneous tissues and to visualize distant migration and possible complications. Conventional spin-echo (SE) T1-weighted and turbo SE proton-density/T2-weighted, plain short tau inversion recovery (STIR), and two STIR sequences with, respectively, water and silicone suppression were applied at 1.
View Article and Find Full Text PDF