Publications by authors named "Radin A Nasirudin"

Background And Purpose: Size-specific dose estimates (SSDE) have been introduced into computed tomography (CT) dosimetry to tailor patients' unique sizes to facilitate accurate CT radiation dose quantification and optimization. The purpose of this study was to develop and validate an automated algorithm for the determination of patient size (effective diameter) and SSDE.

Materials And Methods: A MATLAB platform was used to develop software of algorithms based on image segmentation techniques to automate the calculation of patient size and SSDE.

View Article and Find Full Text PDF

Clinical challenges in pediatrics dose estimation by the displayed computed tomography (CT) dose indices may lead to inaccuracy, and thus size-specific dose estimate (SSDE) is introduced for better-personalized dose estimation. This study aims to estimate pediatric dose adapted to specific size. This retrospective study involved pediatric population aged 0-12 y.

View Article and Find Full Text PDF

We investigated the effects of low-dose multi detector computed tomography (MDCT) in combination with statistical iterative reconstruction algorithms on trabecular bone microstructure parameters. Twelve donated vertebrae were scanned with the routine radiation exposure used in our department (standard-dose) and a low-dose protocol. Reconstructions were performed with filtered backprojection (FBP) and maximum-likelihood based statistical iterative reconstruction (SIR).

View Article and Find Full Text PDF

Purpose: The exciting prospect of Spectral CT (SCT) using photon-counting detectors (PCD) will lead to new techniques in computed tomography (CT) that take advantage of the additional spectral information provided. We introduce a method to reduce metal artifact in X-ray tomography by incorporating knowledge obtained from SCT into a statistical iterative reconstruction scheme. We call our method Spectral-driven Iterative Reconstruction (SPIR).

View Article and Find Full Text PDF

In recent years, dual-energy computed tomography (DECT) has been widely used in the clinical routine due to improved diagnostics capability from additional spectral information. One promising application for DECT is CT colonography (CTC) in combination with computer-aided diagnosis (CAD) for detection of lesions and polyps. While CAD has demonstrated in the past that it is able to detect small polyps, its performance is highly dependent on the quality of the input data.

View Article and Find Full Text PDF

Purpose: Spectral Computed Tomography (SCT) systems equipped with photon counting detectors (PCD) are clinically desired, since such systems provide not only additional diagnostic information but also radiation dose reductions by a factor of two or more. The current unavailability of clinical PCDs makes a simulation of such systems necessary.

Methods: In this paper, we present a Monte Carlo-based simulation of a SCT equipped with a PCD.

View Article and Find Full Text PDF

Purpose: To evaluate quantitative perfusion measurements of dynamic indocyanine green (ICG)-enhanced optical imaging for monitoring synovitis in the hands of patients with inflammatory arthritis compared with dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging and clinical outcome.

Materials And Methods: This study was approved by the ethics committee at the institution. Individual joints (n = 840) in the hands and wrists of 28 patients (14 women; mean age, 53.

View Article and Find Full Text PDF