We report on the first multilocation electron temperature (T_{e}) and flow measurements in an ignition hohlraum at the National Ignition Facility using the novel technique of mid-Z spectroscopic tracer "dots." The measurements define a low resolution "map" of hohlraum plasma conditions and provide a basis for the first multilocation tests of particle and energy transport physics in a laser-driven x-ray cavity. The data set is consistent with classical heat flow near the capsule but reduced heat flow near the laser entrance hole.
View Article and Find Full Text PDFA high resolution (E/ΔE = 1200-1800) Bragg crystal x-ray spectrometer is being developed to measure plasma parameters in National Ignition Facility experiments. The instrument will be a diagnostic instrument manipulator positioned cassette designed mainly to infer electron density in compressed capsules from Stark broadening of the helium-β (1s-1s3p) lines of krypton and electron temperature from the relative intensities of dielectronic satellites. Two conically shaped crystals will diffract and focus (1) the Kr Heβ complex and (2) the Heα (1s-1s2p) and Lyα (1s-2p) complexes onto a streak camera photocathode for time resolved measurement, and a third cylindrical or conical crystal will focus the full Heα to Heβ spectral range onto an image plate to provide a time integrated calibration spectrum.
View Article and Find Full Text PDFThe National Ignition Facility has been used to compress deuterium-tritium to an average areal density of ~1.0±0.1 g cm(-2), which is 67% of the ignition requirement.
View Article and Find Full Text PDFWe demonstrate the hohlraum radiation temperature and symmetry required for ignition-scale inertial confinement fusion capsule implosions. Cryogenic gas-filled hohlraums with 2.2 mm-diameter capsules are heated with unprecedented laser energies of 1.
View Article and Find Full Text PDFOn the National Ignition Facility (NIF), hot electrons generated in laser heated Hohlraums are inferred from the >20 keV bremsstrahlung emission measured with the time integrated FFLEX broadband spectrometer. New high energy (>200 keV) time resolved channels were added to infer the generated >170 keV hot electrons that can cause ignition capsule preheat. First hot electron measurements in near ignition scaled Hohlraums heated by 96-192 NIF laser beams are presented.
View Article and Find Full Text PDFThe first hohlraum experiments on the National Ignition Facility (NIF) using the initial four laser beams tested radiation temperature limits imposed by plasma filling. For a variety of hohlraum sizes and pulse lengths, the measured x-ray flux shows signatures of filling that coincide with hard x-ray emission from plasma streaming out of the hohlraum. These observations agree with hydrodynamic simulations and with an analytical model that includes hydrodynamic and coronal radiative losses.
View Article and Find Full Text PDFWe present measurements of the absolute albedos of hohlraums made from gold or from high-Z mixtures. The measurements are performed over the range of radiation temperatures (70-100 eV) expected during the foot of an indirect-drive temporally shaped ignition laser pulse, where accurate knowledge of the wall albedo (i.e.
View Article and Find Full Text PDFPhys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics
May 1996
X-ray production in the region ˜ 13 nm from laser-produced plasmas has been investigated as a source for projection x-ray lithography. The dependence of x-ray conversion efficiency on target material, intensity, and pulse length has been studied by using a 0.53-µm laser with a maximum of 0.
View Article and Find Full Text PDFThe development of a new time-resolved x-ray spectrometer is reported in which a free-standing x-ray transmission grating is coupled to a soft x-ray streak camera. The instrument measures continuous x-ray spectra with 20-psec temporal resolution and moderate spectral resolution (deltalambda >/= 1 A) over a broad spectral range (0.1-5 keV) with high sensitivity and large information recording capacity.
View Article and Find Full Text PDFBecause several recent reports have indicated a high incidence of hyperlipidemia in insulin-dependent juvenile diabetes, the plasma lipid levels were measured in a population of insulin-dependent diabetic patients to determine if hyperlipidemia is necessarily associated with diabetes. Only one patient had an elevated cholesterol concentration (greater than 220 mg. per deciliter) and two patients had an elevated triglyceride concentration (greater than 140 mg.
View Article and Find Full Text PDF