Publications by authors named "R-B Cavalcante"

Background: SAPIEN3 (S3) is a ubiquitous redo-transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing.

Methods: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed.

View Article and Find Full Text PDF

Background: Our aim was to assess the feasibility of repeat transcatheter aortic valve (TAV) replacement for degenerated Sapien3 (S3) prostheses by simulating subsequent implantation of S3 or Evolut, using in vivo computed tomography-based sizing and the impact on coronary and patient-prosthesis mismatch risks.

Methods: Computed tomography scans from 356 patients with prior S3 TAV replacement implantation were analyzed. The in vivo sizing for second TAV based on averaged area of 3 levels of outflow, mid (narrowest) and inflow, was compared with in vitro recommendations, that is, same size as index S3 for second S3 and 1 size larger for Evolut.

View Article and Find Full Text PDF

In this EACVI clinical scientific update, we will explore the current use of multi-modality imaging in the diagnosis, risk stratification, and follow-up of patients with aortic stenosis, with a particular focus on recent developments and future directions. Echocardiography is and will likely remain the key method of diagnosis and surveillance of aortic stenosis providing detailed assessments of valve haemodynamics and the cardiac remodelling response. Computed tomography (CT) is already widely used in the planning of transcutaneous aortic valve implantation.

View Article and Find Full Text PDF

Background: Consensus-driven criteria have recently been proposed for prediction of mitral transcatheter edge-to-edge repair outcomes, yet validation for response to therapy is needed. We examined the relation between contemporary criteria and outcomes with mitral transcatheter edge-to-edge repair therapy.

Methods: Mitral transcatheter edge-to-edge repair patients were classified according to anatomic and clinical criteria (1) Heart Valve Collaboratory criteria for nonsuitability; (2) commercial indications (suitable); and (3) neither (ie, intermediate).

View Article and Find Full Text PDF

Background: Although transcatheter edge-to-edge repair (TEER) is effective and safe, there is a need for better prediction of optimal outcomes. We aimed to determine predictors of optimal reduction in mitral regurgitation (MR) and survival with TEER.

Methods: We examined mitral anatomy and its change with TEER on outcomes in 183 patients (age, 82 [77-87] years; 53% women).

View Article and Find Full Text PDF