Rev Sci Instrum
October 2024
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy.
View Article and Find Full Text PDFA new pseudolocal tomography algorithm is developed for soft X-ray(SXR) imaging measurements of the turbulent electron temperature fluctuations (δ T) in tokamaks and stellarators. The algorithm overcomes the constraints of limited viewing ports on the vessel wall (viewing angle) and limited number of lines of sight (LOS). This is accomplished by increasing the number of LOS locally in a region of interest.
View Article and Find Full Text PDFNovel spatial, temporal, and energetically resolved measurements of bremsstrahlung hard-x-ray (HXR) emission from runaway electron (RE) populations in tokamaks reveal nonmonotonic RE distribution functions whose properties depend on the interplay of electric field acceleration with collisional and synchrotron damping. Measurements are consistent with theoretical predictions of momentum-space attractors that accumulate runaway electrons. RE distribution functions are measured to shift to a higher energy when the synchrotron force is reduced by decreasing the toroidal magnetic field strength.
View Article and Find Full Text PDFRev Sci Instrum
November 2016
A compact multi-energy soft x-ray camera has been developed for time, energy and space-resolved measurements of the soft-x-ray emissivity in magnetically confined fusion plasmas. Multi-energy soft x-ray imaging provides a unique opportunity for measuring, simultaneously, a variety of important plasma properties (T, n, ΔZ, and n). The electron temperature can be obtained by modeling the slope of the continuum radiation from ratios of the available brightness and inverted radial emissivity profiles over multiple energy ranges.
View Article and Find Full Text PDFRev Sci Instrum
October 2015
The design, calibration, and installation of disruption halo current sensors for the Experimental Advanced Superconducting Tokamak are described in this article. All the sensors are Rogowski coils that surround conducting structures, and all the signals are analog integrated. Coils with two different cross-section sizes have been fabricated, and their mutual inductances are calibrated.
View Article and Find Full Text PDF