Int J Cardiol
November 2014
Laser atherectomy might decrease procedural complications during percutaneous coronary intervention (PCI) of degenerated saphenous vein grafts (SVGs) in case of unstable or thrombotic lesions because of its ability to debulk and vaporize thrombus. We aimed at prospectively evaluating the safety and efficacy of excimer laser coronary angioplasty (ELCA) as a primary treatment strategy in consecutively unstable patients undergoing PCI of degenerated SVG lesions. Seventy-one consecutive patients with non-ST elevation acute coronary syndrome (mean age 69 ± 10 years, 66 men [89%]) undergoing PCI of degenerated SVG were enrolled in a prospective case-control registry, using 2 different distal protection devices (DPDs; FilterWire EZ [Boston Scientific, Natick, Massachusetts; n = 24] and SpiderRX [Ev3, Plymouth, Minnesota; n = 23]) or ELCA (n = 24).
View Article and Find Full Text PDFBackground: Fractional flow reserve (FFR) specifically relates to the severity of a stenosis to the mass of tissue to be perfused. Accordingly, the larger the territory to be perfused, the greater the flow and the pressure gradient induced by maximal hyperemia. Although this notion may be considered intuitive, its unequivocal demonstration is still lacking.
View Article and Find Full Text PDFEuroIntervention
November 2012
Aims: Contrast-induced nephropathy (CIN) is a frequent and potentially harmful complication of percutaneous coronary interventions (PCI), especially in the setting of ST-elevation myocardial infarction (STEMI). We tested the efficacy of a sodium bicarbonate (SB)-based hydration in urgent PCI for STEMI.
Methods And Results: From June 2009 to September 2010, 262 consecutive STEMI patients undergoing urgent PCI were prospectively enrolled and treated by SB-based hydration (154 mEq/L at 3 ml Kg-1 for one hour followed by 1 ml Kg-1 for six hours) (group A).
Catheter Cardiovasc Interv
February 2013
Background: Polymer-coating represents a key component of drug-eluting stent (DES) technology and its possible impact on vessel-wall healing is a matter of debate. The clinical impact of different polymer-coating may be assessed by comparing the outcome of patients treated by DES having the same stent platform and drug, and differing in the polymer. Thus, we compared the clinical outcome of patients treated by Endeavor Zotarolimus-eluting stent (E-ZES) and Resolute Zotarolimus-eluting stent (R-ZES) as they differ in the polymer-coating only.
View Article and Find Full Text PDF