Publications by authors named "R Mathiyarasu"

In-vivo whole body monitors are calibrated with various types of phantoms like Bottle Mannikin absorption phantom (BOMAB), IGOR phantom, Masonite cut sheet phantom, realistic numerical phantoms (NORMAN, ICRP voxel phantom). These phantoms contain either point sources, rod sources, uniform source or radionuclides distributed in soft tissues etc. In this study the efficiency values of Shadow Shield wholebody counter (SSC) for Cs and Co obtained theoretically using ICRP adult voxel male reference phantom (ICRP-AM) having sources distributed in soft tissues and muscles ICRP-AM(S) are compared with the measured efficiencies of Indian BOMAB phantom having mid axial source distribution (BOM-I(A)).

View Article and Find Full Text PDF

Surface mount electronic devices (like resistors, capacitors, and inductors) extracted from the portable electronic devices (mobile phones, USB drives, etc.) have been studied for dose reconstruction using luminescence techniques for radiological or nuclear emergencies. In this work, carbon coated ceramic resistors removed from the electronic instruments are analyzed using thermo luminescence (TL) technique for the retrospective dose reconstruction.

View Article and Find Full Text PDF

This paper discusses the modeling of HPGe detector used in waste assay system using Monte Carlo code FLUKA to determine its detection limits. The modeled detector is validated using experimental point sources efficiencies in the energy range 60 keV-2000 keV. The numerical estimation of efficiency values for Pu present inside a 230 L cotton filled waste drum at various locations along the axis of the detector is discussed.

View Article and Find Full Text PDF

The whole-body counting facility at the Indira Gandhi Centre for Atomic Research uses an in-house built Masonite cut-sheet phantom for the calibration of whole-body monitors. Recently, an Indian Adult BOMAB phantom was procured as an additional utility to augment the facility. The present study is to generate full-energy peak efficiencies (FEPE) of the shielded chair (SC) whole-body counting system using the new BOMAB phantom through Monte Carlo (MC) simulations.

View Article and Find Full Text PDF

In vivo monitoring of actinides in occupational workers is done using Phoswich detector by measuring the low-energy X ray and gamma rays. Quantification of actinides like plutonium and americium in the lungs is extremely difficult due to higher background in the low-energy regions, which is from ambient background as well as from the subject. In the latter case, it is mainly due to the Compton scattering of body potassium, which varies person-to-person.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session1idcdijjgpcouod2sm7kk3oo3k37umss): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once