Metrics derived from continuous glucose monitoring (CGM) systems are often discordant between systems. A major cause is that CGM systems are not standardized; they use various algorithms and calibration methods, leading to discordant CGM readings across systems. This discordance can be addressed by standardizing CGM performance assessments: If manufacturers aim their CGM systems at the same target, then CGM readings will align across systems.

View Article and Find Full Text PDF

Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC) that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing.

View Article and Find Full Text PDF

Heating of the arm and/or hand ("arterialization") is sometimes used in continuous glucose monitoring (CGM) performance studies with the reported aim of reducing differences between venous and capillary glucose concentrations. In this study, the effect of heating on venous glucose concentrations and CGM accuracy was investigated. A heating pad set to 50°C (122°F) was used with 20 participants to heat either the dominant or nondominant arm and hand.

View Article and Find Full Text PDF

The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022.

View Article and Find Full Text PDF

Direct-to-consumer (DTC) tests can be defined as any diagnostic (IVD) test or, more broadly, any medical test using an IVD or medical device, that is marketed directly to consumers without involvement of a health care provider (HCP). Examples are pregnancy tests, alcohol breath tests, blood pressure measurements (medical device), coagulation tests (INR), self-monitoring of blood glucose, continuous glucose monitoring (medical device), HIV tests, HPV tests, SARS-CoV-2 antigen tests, or genetic tests. DTC tests fulfil various customer needs such as making rapid decisions (e.