The Olburgen sewage treatment plant has been upgraded to improve the effluent quality by implementing a separate and dedicated treatment for industrial (potato) wastewater and reject water. The separate industrial treatment has been realized within a beneficial public-private partnership. The separate treatment of the concentrated flows of industrial wastewater and sludge treatment effluent proved to be more cost-efficient and area and energy efficient than a combined traditional treatment process.
View Article and Find Full Text PDFAt a full-scale single-stage nitritation-anammox reactor, off-gas measurement for nitric oxide (NO) and nitrous oxide (N(2)O) was performed. NO and N(2)O are environmental hazards, imposing the risk of improving water quality at the cost of deteriorating air quality. The emission of NO during normal operation of a single-stage nitritation-anammox process was 0.
View Article and Find Full Text PDFThe airlift reactor technology has been successfully applied at full scale for both COD and nitrogen removal. In this study, the results of the biofilm development and biological performance of two full scale reactors are discussed. At Paulaner Brewery in Munich, the airlift reactor was applied for COD and ammonia removal of anaerobically treated wastewater.
View Article and Find Full Text PDF