Publications by authors named "R C Canby"

Article Synopsis
  • A new dual chamber leadless pacemaker system utilizes a temperature-based sensor to monitor heart rate response during exercise, focusing on its effectiveness in both the right ventricle and right atrium.
  • An exercise test was conducted 6 weeks post-implant on eligible subjects to evaluate the pacing response of the ventricular and atrial devices, measuring if the rate increased proportionately with metabolic workload.
  • Results showed that both the ventricular and atrial devices had mean rate-response slopes (0.93 and 0.91, respectively) within the acceptable range, indicating that the temperature-based sensor effectively adjusts pacing to meet increased metabolic demands.
View Article and Find Full Text PDF
Article Synopsis
  • - The Aveir DR system is a new type of dual-chamber leadless pacemaker that features separate atrial and ventricular components capable of communicating wirelessly for synchronized heart pacing.
  • - A study involving 399 patients showed that the success rates of implant-to-implant (i2i) communication between the atrial and ventricular pacemakers exceeded 90% at all tested intervals over six months.
  • - Improvements in communication success were noted, particularly for patients with initial lower success rates, suggesting benefits from reprogramming and device stabilization over time.
View Article and Find Full Text PDF
Article Synopsis
  • * This system uses two leadless devices that communicate with each other instead of traditional wires, which makes it unique in its design.
  • * The paper provides an overview of the dual-chamber pacemaker implantation process, highlighting important steps to ensure safe and efficient procedures.
View Article and Find Full Text PDF

Background: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated.

Methods: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023.

View Article and Find Full Text PDF

Background: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported.

Objective: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system.

View Article and Find Full Text PDF