We report scanning magnets manufactured at the Huazhong University of Science and Technology Proton Therapy Facility for use in pencil-beam nozzles in a fixed beamline. Such nozzles allow us to control the trajectory of proton beams to form the requisite radiation field for tumor therapy. Two AC-excited scanning magnets operate at a maximum frequency of 100 and 50 Hz, respectively, generating significant eddy currents that raise the temperature.