Objective: This study aims to evaluate a novel prone position ventilation device designed to enhance patient safety, improve comfort, and reduce adverse events, facilitating prolonged tolerance in critically ill patients.
Methods: A randomized controlled trial was conducted on 60 critically ill patients from January 2020 to June 2023. Of which, one self-discharged during treatment and another was terminated due to decreased oxygenation, leaving an effective sample of 58 patients.
Front Cell Infect Microbiol
February 2024
Introduction: The contamination of dental unit waterlines (DUWLs) poses a significant risk of cross-infection in dentistry. Although chemical disinfectants have been effective in reducing number of bacteria, they do have limitations.
Methods: This study aimed to investigate the potential of chlorogenic acid, a natural substance with broadspectrum antibacterial properties, for treating DUWLs.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue
May 2022
Objective: To analyze clinical characteristics of patients with novel coronavirus Omicron variant of concern infection, and to provide practical data and experience for subsequent clinical treatment.
Methods: A retrospective analysis was performed for the clinical data of 5 cases with novel coronavirus Omicron variant of concern infection treated in the First Hospital of Jiaxing from December 18, 2021 to January 28, 2022. The patients' clinical data were recorded, including gender, age, length of hospital stay, vaccination status, clinical symptoms, laboratory indicators [white blood cell count (WBC), lymphocyte count (LYM), eosinophil count (EOS), hypersensitivity C-reactive protein (hs-CRP), novel coronavirus antibody immunoglobulin (IgG and IgM)], chest CT, treatment course and disease outcome.
Purpose: Anatomical changes occurred during the treatment course of radiation therapy for lung cancer patients may introduce clinically unacceptable dosimetric deviations from the planned dose. Adaptive radiotherapy (ART) can compensate these dosimetric deviations in subsequent treatments via plan adaption. Determining whether and when to trigger plan adaption during the treatment course is essential to the effectiveness and efficiency of ART.
View Article and Find Full Text PDFSignal Transduct Target Ther
October 2021
The long-term immunity and functional recovery after SARS-CoV-2 infection have implications in preventive measures and patient quality of life. Here we analyzed a prospective cohort of 121 recovered COVID-19 patients from Xiangyang, China at 1-year after diagnosis. Among them, chemiluminescence immunoassay-based screening showed 99% (95% CI, 98-100%) seroprevalence 10-12 months after infection, comparing to 0.
View Article and Find Full Text PDFPurpose: Frequency of conventional kV-image guidance is sometimes sacrificed to reduce concomitant risk, leaving deviations of unguided fractions unknown. MV-imaging and treatment dose can be collectively optimized on Halcyon, where fractional MVCBCT provides complete anatomic records for course-wide dose reconstruction. By retrospective dose accumulation, this work simulated the impact of imaging frequency on patient treatment dose on the platform of Halcyon.
View Article and Find Full Text PDFTo evaluate the feasibility of dose-guided adaptive radiotherapy (ART) based on deformable image registration (DIR) using fractional megavoltage cone-beam CT (MVCBCT) images from Halcyon system that uses identical beams for treatment and imaging and to retrospectively investigate the influence of anatomic changes on target coverage and organ-at-risk (OAR) sparing across various tumor sites. Four hundred twenty-two MVCBCT images from 16 patients (three head and neck, seven thoracic, three abdominal, and three pelvic cases) treated in a phase II clinical trial for Halcyon were selected. DIR between the planning CT and daily MVCBCT image was implemented by Velocity software to create pseudo CT.
View Article and Find Full Text PDFObjective: High-dose-rate (HDR) afterloading brachytherapy using Iridium-192 source involves large radiation activity varieties due to fast decay. It was unknown but clinically desirable to evaluate its impacts on patient outcomes to support more informed decisions.
Methods: Data of 510 cervical carcinoma (CC) patients were retrospectively included.
Background And Purpose: To evaluate the impact of deformation magnitude and image modality on deformable-image-registration (DIR) accuracy using Halcyon megavoltage cone beam CT images (MVCBCT).
Materials And Methods: Planning CT images of an anthropomorphic Head phantom were aligned rigidly with MVCBCT and re-sampled to achieve the same resolution, denoted as pCT. MVCBCT was warped with twenty simulated pre-known virtual deformation fields (T, i = 1-20) with increasing deformation magnitudes, yielding warped CBCT (wCBCT).
In our previous study, we identified a class of 4-substituted coumarins as a powerful microtubule inhibitors binding to the colchicine site of -tubulin. H6 showed potent anti-proliferative ability with IC values from 7 to 47 nM, and remarkable ability to reduce tumor growth in several xenograft models including taxol resistant tumor models. However, the extremely hydrophobicity limited its clinical application.
View Article and Find Full Text PDFThe interactive adjustment of the optimization objectives during the treatment planning process has made it difficult to evaluate the impact of beam quality exclusively in radiotherapy. Without consensus in the published results, the arbitrary selection of photon energies increased the probability of suboptimal plans. This work aims to evaluate the dosimetric impact of various photon energies on the sparing of normal tissues by applying a preconfigured knowledge-based planning (RapidPlan) model to various clinically available photon energies for rectal cancer patients, based on model-generated optimization objectives, which provide a comparison basis with less human interference.
View Article and Find Full Text PDFPurpose: To assess the criticality of calculation deviations induced by fractional image-guided-couch-shifts for Halcyon MV cone beam CT (CBCT) dose, which is incorporated as part of total treatment dose.
Methods: Eclipse-calculated imaging dose was first validated in 'Cheese Phantom' by measurement. Then, the actual imaging dose (D) for 18 historical patients of various sites were recalculated based on 513 MV CBCT-guided-couch-shift data, and compared with reference computations based on treatment isocentre (D).
Tetrandrine is an effective ingredient isolated from the roots of a frequently used medicinal plant Stephania tetrandra S. Moore. It has been used for the management of arthritis in China, but the precise mechanism remains unclear.
View Article and Find Full Text PDFWe investigate the impact of magnetic resonance (MR) on the staging and radiotherapy planning for patients with nonsmall cell lung cancer (NSCLC).A total of 24 patients with NSCLC underwent MRI, which was fused with radiotherapy planning CT using rigid registration. Gross tumor volume (GTV) was delineated not only according to CT image alone (GTVCT), but also based on both CT and MR image (GTVCT/MR).
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2016
The unwanted radiation transmission through the multileaf collimators could be reduced by the jaw tracking technique which is commercially available on Varian TrueBeam accelerators. On the basis of identical plans, this study aims to investigate the dosimetric impact of jaw tracking on the volumetric-modulated arc therapy (VMAT) plans. Using Eclipse treatment planning system (TPS), 40 jaw-tracking VMAT plans with various tumor volumes and shapes were optimized.
View Article and Find Full Text PDFThe eco-friendly poly(propylene carbonate) (PPC)/cellulose acetate butyrate (CAB) blends were prepared by melt-blending in a batch mixer for the first time. PPC and CAB were partially miscible because of the drastically shifted glass transition temperatures of both PPC and CAB, which originated from the specific interactions between carbonyl groups and hydroxyl groups. The incorporation of CAB into PPC matrix enhanced not only tensile strength and modulus of PPC dramatically, but also improved heat resistance and thermal stability of PPC significantly.
View Article and Find Full Text PDFBackground: To investigate the feasibility and accuracy of dose calculation in cone beam CT (CBCT) data sets.
Methods: Kilovoltage CBCT images were acquired with the Elekta XVI system, CT studies generated with a conventional multi-slice CT scanner (Siemens Somatom Sensation Open) served as reference images. Material specific volumes of interest (VOI) were defined for commercial CT Phantoms (CATPhan and Gammex RMI) and CT values were evaluated in CT and CBCT images.