Based-MCP position-sensitive anode photon-counting imaging detector is good at detecting extremely faint light, which includes micro-channel plate (MCP), position-sensitive anode and readout, and the performances of these detectors are mainly decided by the position-sensitive anode. As a charge division anode, Vernier anode using cyclically varying electrode areas which replaces the linearly varying electrodes of wedge-strip anode can get better resolution and greater electrode dynamic range. Simulation and design of the Vernier anode based on Vernier's decode principle are given here.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
August 2010
Photon counting detectors based on microchannel plate have widespread applications in astronomy. The present paper deeply studies secondary electron of microchannel plate in extreme ultraviolet. A theoretical model describing extreme ultraviolet-excited secondary electron yield is presented, and the factor affecting on the secondary electron yields of both electrode and lead glass which consist of microchannel plate is analyzed according to theoretical formula derived from the model.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
November 2008
A laser-produced plasma (LPP) source with liquid aerosol spray target and nanosecond laser was developed, based on both soft X-ray radiation metrology and extreme ultraviolet projection lithography (EUVL). The LPP source is composed of a stainless steel solenoid valve whose temperature can be continuously controlled, a Nd : YAG laser with pulse width, working wavelength and pulse energy being 7 ns, 1.064 microm and 1J respectively, and a pulse generator which can synchronously control the valve and the laser.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
March 2005
A soft X-ray reflectometor with laser-produced plasma source developed in the authorial lab is presented for the measurements of efficiencies of gratings, transmission of filter and reflectance of multilayer coatings. The reflectometer is composed of a soft X-ray laser-produced plasma source, a grazing incidence monochromator with a constant deviation angle, a vacuum chamber, a sample table, a photo-electronic unit and a computer controlling unit. The working wavelength is from 8 to 30 nm and the maximum sample size is 130 mm long by 120 mm wide by 120 mm high.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
March 2005
The soft X-ray and vacuum ultraviolet sources developed in CIOMP are presented. The wall-stabilized argon arc source with spectrum stability and repeatability of +/-0.3% is applied to the calibration of spectrum intensity distribution of the vacuum ultraviolet instruments as an absolute standard source.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
January 2004
This paper presents a method to detect and measure spectrum intensity from a laser plasma soft X-ray source. A Channel Electron Multiplier (CEM) and a calibrated silicon photodiode were used as detectors in this method, the former is a nonstandard detector and the latter is a standard one. Charge-sensitive preamplifiers were used for measuring total charges generated by detectors, and a monochromator with high resolution was employed as the spectrometer.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
February 2003
This paper describes a debris-free laser plasma soft X-ray source with a gas target, which has high operating frequency and can produce strong soft X-ray radiation. The valve of this light source is drived by a piezoelectrical ceramic whose operating frequency is up to 400 Hz. In comparison with laser plasma soft X-ray sources using metal target, the light source is debris-free.