Multi-criteria optimization (MCO) is a method that was added to treatment planning to create high-quality treatment plans. This study aimed to investigate the effectiveness of MCO in combination with knowledge-based planning (KBP) in radiotherapy for left-sided breasts, including regional nodes. Dose/volume parameters were evaluated for manual plans (MP), KBP, and KBP + MCO.
View Article and Find Full Text PDFPurpose: To investigate the performance of a model-based optimization process for volumetric modulated arc therapy (VMAT) applied to prostate cancer patients with the multi-planner.
Methods And Materials: The 120 prostate plans for VMAT treatment were entered into the database system of the RapidPlan (RP) knowledge-based treatment planning. The treatment planning data for each plan was used to create and train the RP model.
Purpose: The purpose of the study was to investigate the dosimetric characteristics of radiophotoluminescent glass dosimeters (RGDs) for pencil beam scanning proton therapy. The RGD's end-to-end testing of intensity-modulated proton therapy (IMPT) plans was also evaluated.
Materials And Methods: The dosimetric characteristics of the GD-302M type glass dosimeter were studied in terms of uniformity, short-term and long-term reproducibility, stability of the magazine position readout, dose linearity in the range from 0.
Background: Stereotactic radiosurgery (SRS) is an alternative to surgery as it precisely delivers single-large doses to small tumors. Cast nylon is used in phantom due to its computed tomography (CT) number of about 56-95 HU, which is close to that of the soft tissue. Moreover, cast nylon is also more budget-friendly than the commercial phantoms.
View Article and Find Full Text PDFPurpose: This study aimed to determine the integral depth-dose curves and assess the geometric collection efficiency of different detector diameters in proton pencil beam scanning.
Materials And Methods: The Varian ProBeam Compact spot scanning system was used for this study. The integral depth-dose curves with a proton energy range of 130 to 220 MeV were acquired with 2 types of Bragg peak chambers: 34070 with 8-cm diameter and 34089 with 15-cm diameter (PTW), multi-layer ionization chamber with 12-cm diameter (Giraffe, IBA Dosimetry), and PeakFinder with 8-cm diameter (PTW).
Background: Ultrahypofractionation can shorten the irradiation period. This study is the first dosimetric investigation comparing ultrahypofractionation using volumetric arc radiation therapy (VMAT) and intensity-modulated proton radiation therapy (IMPT) techniques in postmastectomy treatment planning.
Materials And Methods: Twenty postmastectomy patients (10-left and 10-right sided) were replanned with both VMAT and IMPT techniques.
Introduction: The well-being of breast cancer patients is essential, especially fertility in patients of reproductive age. The objective of this study was to estimate the radiation doses to the ovaries and uterus for different treatment techniques of breast cancer irradiation using radio-photoluminescent glass dosimeters (RPLDs).
Methods: A Farmer-type ionisation chamber (IBA FC-65G) and RPLDs were used to measure in- and out-of-field radiation doses in a solid water phantom.
Purpose: To observe the effectiveness of the practical instruction sheet and the educational video for left-sided breast treatment in a patient receiving deep inspiration breath hold (DIBH) technique. Two parameters, simulation time and patient satisfaction, were assessed through the questionnaire.
Methods: Two different approaches, which were the instruction sheet and educational video, were combinedly used to assist patients during DIBH procedures.
Radiation protection in the scrotum to reduce the risk of genetic effect in the future is very important. This study aimed to measure the scrotal dose outside the treatment fields by using the radio-photoluminescence glass dosimeter (RPLGD). The characteristics of RPLGD model GD-302M were studied.
View Article and Find Full Text PDF