It was the aim of this study to compare in vitro closure time (PFA-100), reflecting platelet-related primary hemostasis, to more platelet-specific tests like whole blood electrical aggregometry and platelet surface antigen expression in healthy volunteers. In vitro closure time was measured using a PFA-100. Platelet surface antigen expression (CD63, CD62-P, CD42b, CD36, CD31) was determined in accordance with the consensus protocol for flow-cytometric characterisation of platelet function.
View Article and Find Full Text PDFA group of 100 patients with intermittent claudication (70 male, 30 female), treated with I00 mg ASA per day, were followed over 18 months after elective percutaneous balloon angioplasty. Platelet function was monitored over a period of 12 months by corrected whole blood aggregometry (CWBA). Upon stimulation by arachidonic acid (AA), adenosine diphosphate (ADP) and collagen, CWBA-results were obtained by an electronic acquisition and evaluation system correcting for hematocrit and platelet count of the blood sample.
View Article and Find Full Text PDFBleeding problems in orthotopic liver transplantation (OLT), starting immediately after reperfusion of the graft, are complicating the outcome of transplantation. Platelets may be involved in this situation, but there is still a lack of information about the influence of UW solution on platelet function. We evaluated the effect of UW solution on in vitro platelet aggregability in healthy volunteers using whole blood electrical aggregometry and concluded, that UW solution causes impaired platelet aggregability and may contribute to bleeding problems during OLT.
View Article and Find Full Text PDFJ Pharmacol Toxicol Methods
September 1995
Previous studies have shown that differing qualities of blood specimen seem to influence whole blood electrical aggregometry (WBEA), making it difficult to standardize the method. The aim of this study was to investigate the impact of hematocrit (HCT) and platelet count (PLC) on in vitro platelet aggregation in citrated whole blood (CWB) in order to compensate for their possible effects on impedance aggregometry. Red blood cells and blood platelets were isolated from fresh citrated whole blood taken from 15 healthy donors (mean age = 26 years) and recombined to 20 physiologically relevant combinations of hematocrit and platelet count (HCT: 20-50, PLC: 100-500).
View Article and Find Full Text PDFJ Heart Lung Transplant
August 1993
Clinical application of artificial blood pumps for mechanical circulatory support has been hampered by thromboembolic events. The underlying mechanisms are complicated and may differ from patient to patient. Because the calf is commonly used for artificial heart studies, the object was to determine the value of data gained in an animal model.
View Article and Find Full Text PDF