Surg Laparosc Endosc Percutan Tech
November 2024
Background: Posterior component separation with transversus abdominis release (TAR) is a valuable adjunct to address incisional hernia defects. Currently, bilateral docking is a standard technique for robotic TAR. The aim of this study is to describe our technique for extended totally extraperitoneal (eTEP) repair with bilateral TAR through a bottom single-dock robotic approach for hernias at the level of the umbilicus or higher.
View Article and Find Full Text PDFJ Laparoendosc Adv Surg Tech A
November 2024
Recent guidelines have recommended minimally invasive surgery (MIS) for unilateral inguinal hernia due to reduced chronic pain. The most performed approaches consist of posterior mesh placement by the transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) techniques. However, it remains debatable whether the advantage of those techniques stems from the MIS approach or posterior mesh placement or both.
View Article and Find Full Text PDFSurg Endosc
December 2024
Aim: Minimally invasive inguinal hernia repair has become increasingly accepted, demonstrating superior outcomes over open procedures in postoperative complications. However, certain postoperative complications, such as seroma, remain a dilemma, with many attributing it to the management of the hernia sac. We aimed to perform a systematic review and meta-analysis comparing the reduction versus abandonment of the hernia sac during laparoscopic inguinal hernia repair.
View Article and Find Full Text PDFBackground: The incidence of incisional hernia (IH) after an open abdominal aortic aneurysm (AAA) repair can reach up to 35%, contributing to long-term morbidity. Individual studies have been limited in identifying modifiable risk factors for IH after an open AAA repair. This meta-analysis aims to review all the risk factors for IH after an open AAA repair.
View Article and Find Full Text PDFSurgery
December 2024
Background: Randomized studies have endorsed nonabsorbable prosthetics for contaminated ventral hernia surgery, yet the broader applicability and impact on patient-reported outcomes are still questioned. Here, we evaluated the long-term outcomes of elective contaminated ventral hernia repairs (based on Centers of Disease Control and Prevention [CDC] wound classification) using real-world data from a multicenter US cohort, focusing on quality of life and postoperative pain.
Methods: The Abdominal Core Health Quality Collaborative database was queried for patients undergoing elective contaminated (CDC class II-IV) ventral hernia repair (2013-2023).
Introduction: Over the last few decades, there has been an increase in the use of a minimally invasive (MIS) approach for complex hernias involving component separation. A robotic platform provides better visualization and mobilization of tissues for component separation. We aim to assess the outcomes of open and robotic-assisted approaches for large VHR utilizing the ACHQC national database.
View Article and Find Full Text PDFJ Abdom Wall Surg
July 2024
Hernia registries report that guidelines are not always implemented by general surgeons and suggest that the success rate of this procedure is higher in hernia specialty centers. There are many definitions of hernia centers, but their objectives consist of improving healthcare by homogenizing the clinical practice. We performed a systematic review and meta-analysis to analyze hernia centers' definitions and compare hernia centers with non-specialized centers.
View Article and Find Full Text PDFPurpose: Individual studies indicate poorer outcomes for smokers after hernia repair. Previous meta-analyses have examined the impact of smoking on specific outcomes such as recurrence and surgical site infection, but there has been a lack of comprehensive consensus or systematic review on this subject. Addressing this gap, our study undertakes a systematic review and meta-analysis to assess the impact of smoking on the outcomes of ventral hernia repair (VHR) and inguinal hernia repair.
View Article and Find Full Text PDFPurpose: Recent guidelines indicate the use of mesh in UHR for defects > 1 cm, as it reduces recurrence, with 10% recurrence rate compared to up to 54.5% with primary closure. However, Nguyen et al.
View Article and Find Full Text PDFPurpose: The transinguinal preperitoneal (TIPP) technique is an open approach to groin hernia repair with posteriorly positioned mesh supposed to reduce recurrence rates. However, transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) techniques have similar mesh positioning with the advantages of minimally invasive surgery (MIS). Hence, we performed a systematic review and meta-analysis comparing TIPP and MIS for groin hernia repair.
View Article and Find Full Text PDFIntroduction: Ventral hernia repair (VHR) is one of the most common procedures in the United States, and drains are used in over 50% of mesh repairs. The aim of this study is to investigate the impact of drains on surgical site occurrences (SSO) and infection (SSI) after open and minimally invasive retromuscular VHR with mesh.
Methods: A retrospective review of prospectively collected data from the ACHQC was performed to include adult patients who underwent elective VHR with retromuscular mesh placement.
ChatGPT is a conversational AI model developed by OpenAI to generate human-like text based on the input it receives. ChatGPT has become increasingly popular, and the general public may use this tool to ask questions about different medical conditions. There is a lack of data to demonstrate ChatGPT is able to provide reliable information on medical conditions.
View Article and Find Full Text PDFSurgery
April 2024
ChatGPT is a conversational AI model developed by OpenAI designed to generate human-like text based on the input it receives. ChatGPT has become increasingly popular, and the general public may use this tool to ask questions about different medical conditions. There is a lack of data showing if ChatGPT is able to provide reliable information on medical conditions to the general public.
View Article and Find Full Text PDFJ Laparoendosc Adv Surg Tech A
October 2023
The type of mesh used in inguinal hernia repairs remains controversial. There are limited data looking at specific mesh-related complications. The objective of this study is to assess postoperative 90-day outcomes in lightweight (LW) and heavyweight (HW) anatomical mesh in minimally invasive inguinal hernia repairs.
View Article and Find Full Text PDFIntroduction: Reinforcement of crural closure with synthetic resorbable mesh has been proposed to decrease recurrence rates after hiatal hernia repair, but continues to be controversial. This systematic review aims to evaluate the safety, efficacy, and intermediate-term results of using biosynthetic mesh to augment the hiatus.
Methods: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed throughout this systematic review.
Introduction: Social media is now a ubiquitous form of communication. It has allowed individuals to connect and share ideas across the country and across the globe. Twitter allows user to share thoughts in 280-character "tweets," while also connecting these messages to community posts with hashtags.
View Article and Find Full Text PDFBackground: In the past years, there has been increasing evidence that supports the use of permanent mesh in contaminated wounds. Given this increased evidence, the indications to opt for slowly absorbable "biosynthetic" prostheses have been questioned. To address this, we compared the outcomes of slowly absorbable mesh in contaminated cases in a well-matched multicentric cohort.
View Article and Find Full Text PDFWe present our algorithmic approach for symptomatic ventral hernias with Diastasis of the Rectus Abdominis Muscle (DRAM). Retrospective analysis of patients with symptomatic ventral hernias and DRAM undergoing hernia repair and plication of DRAM from July 2018-March 2021 was conducted. Based on our algorithm, patients were selected for an Endoscopic Onlay Repair (ENDOR) or a Robotic Extended Totally Extraperitoneal Ventral Repair (R-eTEP).
View Article and Find Full Text PDFJ Am Coll Surg
February 2023
Background: Traditionally, the use of absorbable mesh in contaminated fields aimed to reduce postoperative morbidity at the expense of increased hernia recurrence. This dogma has recently been challenged in randomized trials that demonstrate the advantages of permanent mesh in this setting. Although these studies are of high quality, their reproducibility across institutions is limited.
View Article and Find Full Text PDFThe laparoscopic intracorporeal rectus aponeuroplasty (LIRA) was developed as an alternative for minimally invasive ventral hernia repair. This technique allows the closure of the defect and restoration of the midline without tension by plication of both aponeurosis of the abdominal rectus muscles combined with a minimally invasive intraperitoneal underlay mesh repair. The objective of this study is to report our early experience with the Robotic-LIRA (R-LIRA) technique and its safety and short-term efficacy.
View Article and Find Full Text PDF