This study used friction stir-back extrusion to fabricate the AZ91 + 3 wt% bioactive glass gradient composite wire. The microstructure, mechanical properties, and corrosion resistance of a material in a simulated body fluid were investigated. Three 2-mm diameter holes with varying hole patterns were drilled in the cross-section of the AZ91 rod to apply 3 wt % bioactive glass to the AZ91 matrix.