Publications by authors named "Porenta G"

The enormous progress made in recent years in the field of information and communication technology and also in sensor and computer technology has affected numerous fields of medicine and is capable of inducing even radical changes in diagnostic and therapeutic processes. This is particularly true for cardiology, where, for example, telemetric monitoring of cardiac and circulatory functions has been in use for many years. Nevertheless, broad application of newer telemedical processes has not yet been achieved to the extent one would expect from the encouraging results of numerous clinical studies in this field and the state of the art of the underlying technology.

View Article and Find Full Text PDF

Background: The right ventricle serves as the subaortic systemic ventricle (sysRV) in patients with congenitally corrected transposition of the great arteries (ccTGA) and in patients with transposition of the great arteries (TGA) surgically repaired by an atrial switch. SysRV can lead to late complications, primarily heart failure, significant regurgitation of the systemic atrioventricular (AV) valve, and ventricular arrhythmias with sudden cardiac death. We sought to investigate the value of 2D- and 3D-echocardiographic parameters of sysRV function.

View Article and Find Full Text PDF

Aim: We compared and delineated possible differences of model-based analysis of ECG-gated SPECT using (⁹⁹m)Tc-sestamibi (Tc-SPECT) with ECG-gated ¹⁸F-fluorodeoxyglucose-PET (FDG-PET) for determination of end-diastolic (EDV) and end-systolic (ESV) cardiac volumes, left ventricular ejection fraction (LVEF), and myocardial mass (LVMM).

Patients, Methods: 24 patients (21 men; age: 54±12years) with coronary artery disease underwent Tc-SPECT and FDG-PET imaging for evaluation of myocardial perfusion and viability. By using model-based analysis EDV, ESV, LVEF and LVMM were calculated from short axis images of both Tc-SPECT and FDG-PET.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to compare quantitative ECG-gated single-photon emission computed tomography (SPECT) (QGS) and model-based ECG-gated single-photon emission computed tomography (MBGS) for determination of end-diastolic cardiac volume (EDV), end-systolic cardiac volume (ESV), and left ventricular ejection fraction (LVEF). The accuracy of both methods was evaluated by measurements obtained from contrast left ventriculography (LVG).

Methods: Forty-five patients (40 male, age: 55+/-11 years) with coronary artery disease were studied by angiography and ECG-gated SPECT using technetium-99m-sestamibi for the evaluation of myocardial perfusion and LVEF.

View Article and Find Full Text PDF

Objective: This study compared the diagnostic accuracy of different approaches of case-based reasoning (CBR) for the assessment of coronary artery disease (CAD) using thallium-201 myocardial perfusion scintigraphy in comparison with coronary angiography.

Methods And Material: For each scintigraphic image set, regional myocardial tracer uptake was obtained by polar map analysis. CBR algorithms based on a similarity measure were employed to identify similar scintigraphic images within the case library, where each case contained the scintigraphic data together with results of coronary angiography.

View Article and Find Full Text PDF

Traditional Chinese Medicine (TCM) postulates an interaction between the lung as a Yin-organ and the large intestine as a Yang-organ. The aim of this pilot study was to investigate in asthmatic school age children whether treatment with laser acupuncture and probiotics according to TCM portends a clinical benefit to standard medical treatment performed according to pediatric guidelines. Seventeen children aged 6-12 yr with intermittent or mild persistent asthma were enrolled in this randomized, placebo-controlled, double-blind pilot study.

View Article and Find Full Text PDF

Unlabelled: Angiography of patients with typical chest pain reveals normal epicardial coronary arteries in about 20%. Coronary flow reserve (CFR) determination is an elaborate, but helpful, task, as only the evidence of microvascular disease enables appropriate therapy. We prospectively evaluated the incidence of a dysfunctional microcirculation and searched for predictive parameters of a reduced CFR.

View Article and Find Full Text PDF

Aim: We investigated the impact of photon attenuation in myocardial perfusion imaging with SPECT and PET in patients with coronary artery disease. In fact, the regional tracer distribution can be quantitatively assessed by polar map analysis if the effects of photon attenuation are accounted for. PET imaging permits accurate measurement of and correction for photon attenuation, whereas results of attenuation correction in SPECT imaging have been inconsistent.

View Article and Find Full Text PDF

Background: Approximately 10-30% of patients with typical chest pain present normal epicardial coronaries. In a proportion of these patients, angina is attributed to microvascular dysfunction. Previous studies investigating whether angina is the result of abnormal resting or stress perfusion are controversial but limited by varying inclusion criteria.

View Article and Find Full Text PDF

Unlabelled: The purpose of this study was to evaluate myocardial electrocardiography (ECG)-gated 13N-ammonia (13N-NH3) PET for the assessment of cardiac end-diastolic volume (EDV), cardiac end-systolic volume (ESV), left ventricular (LV) myocardial mass (LVMM), and LV ejection fraction (LVEF) with gated 18F-FDG PET as a reference method.

Methods: ECG-gated 13N-NH3 and 18F-FDG scans were performed for 27 patients (23 men and 4 women; mean+/-SD age, 55+/-15 y) for the evaluation of myocardial perfusion and viability. For both 13N-NH3 and 18F-FDG studies, a model-based image analysis tool was used to estimate endocardial and epicardial borders of the left ventricle on a set of short-axis images and to calculate values for EDV, ESV, LVEF, and LVMM.

View Article and Find Full Text PDF

Background: Measurement of myocardial blood flow (MBF) by dynamic nitrogen 13 ammonia (NH(3)) positron emission tomography (PET) uses tracer kinetic modeling to analyze time-activity curves. We compared 2 commonly used models with 2 compartments (2C) and 3 compartments (3C) for quantification of MBF and coronary flow reserve (CFR).

Methods And Results: Seventy-seven patients underwent NH(3) PET at rest and during hyperemia.

View Article and Find Full Text PDF

Unlabelled: The aim of this study was to compare nonfluoroscopic electroanatomic mapping (NOGA), SPECT perfusion imaging, and PET metabolic imaging for assessment of myocardial viability. In particular, we sought to elucidate differences of electromechanical properties between the perfusion/metabolism mismatch as an indicator of a potentially reversible ischemic injury and the perfusion/metabolism match indicating irreversibly damaged myocardial tissue.

Methods: Twenty-one patients with coronary artery disease underwent NOGA mapping of endocardial unipolar voltage, cardiac 18F-FDG PET of glucose utilization, and resting 201Tl SPECT of myocardial perfusion.

View Article and Find Full Text PDF

Unlabelled: This study presents and evaluates a model-based image analysis method to calculate from gated cardiac (18)F-FDG PET images diastolic and systolic volumes, ejection fraction, and myocardial mass of the left ventricle. The accuracy of these estimates was delineated using measurements obtained by MRI, which was considered the reference standard because of its high spatial resolution.

Methods: Twenty patients (18 men, 2 women; mean age +/- SD, 59 +/- 12 y) underwent electrocardiography-gated cardiac PET and MRI to acquire a set of systolic and diastolic short-axis images covering the heart from apex to base.

View Article and Find Full Text PDF

Objective: Because hibernation is considered a down-regulation of contractile function in response to reduced regional myocardial perfusion, hibernating myocardium is expected to be supplied by a critically stenosed or even occluded coronary artery. Thus, high-dose dobutamine has been postulated to cause ischemia and reworsening of myocardial function (biphasic response), whereas myocardium that demonstrates sustained improvement with high-dose dobutamine should not be supplied by a significantly stenosed vessel. This study evaluates the type of dobutamine response-biphasic versus sustained improvement-of dyssynergic myocardium in relation to its angiographically documented blood supply.

View Article and Find Full Text PDF

In case-based studies, controls are retrospectively assigned to patients in order to permit a statistical evaluation of the study results through a comparison of the main outcome measures for the patient and retrieved control groups. Inappropriate selection of the controls by using false retrieval parameters or a false algorithm might lead to an incorrect data analysis and a false interpretation of the results. The main hypothesis of the presented study was that, if the matching baseline parameters were at least nearly perfectly selected, then the outcomes of the matched pairs should be similar, or no significant differences in study outcome should be observed between the patients and the matched controls.

View Article and Find Full Text PDF

The number of patients with heart failure secondary to chronic ischemic heart disease, also called ischemic cardiomyopathy, is increasing in clinical cardiology. Left ventricular dysfunction after ischemic episodes has been shown to be potentially reversible, as in the case of hibernating or stunned myocardium. Thus, the detection of viable myocardium is of critical importance for a therapeutic stratification of patients with left ventricular dysfunction.

View Article and Find Full Text PDF

Whether asymptomatic patients with severe aortic stenosis benefit from surgery remains unclear. We report our data recently published in the New England Journal of Medicine on the natural history of this disease and predictors of outcome.

View Article and Find Full Text PDF

Unlabelled: This study evaluated the diagnostic accuracy of case-based reasoning (CBR) to automatically detect significant coronary artery disease from dipyridamole 201Tl myocardial SPECT perfusion scintigrams.

Methods: The study population included 240 patients (182 men, 58 women; mean age +/- SD, 61 +/- 12 y) on whom coronary angiography and perfusion scintigraphy were performed within 6 +/- 11 d of each other. The patients were divided into two groups according to the presence or absence of significant coronary disease in any major coronary vessel.

View Article and Find Full Text PDF

This study sought to delineate the impact of the rate pressure product on intraluminal Doppler velocity measurements and to determine the relation between poststenotic vasodilator reserve and percent luminal obstruction in coronary vessels. Twenty patients with single-vessel coronary disease were studied prior to coronary angioplasty and at follow-up 6 months later. Intracoronary velocity reserve after administration of adenosine was measured distal to the stenosis with a Doppler-tipped guide wire and was compared to quantitative coronary angiography and adenosine myocardial perfusion scintigraphy.

View Article and Find Full Text PDF

Objectives: This study was performed to determine the feasibility, accuracy and reproducibility of real-time volumetric three-dimensional echocardiography (3-D echo) for the estimation of mitral valve area in patients with mitral valve stenosis.

Background: Planimetry of the mitral valve area (MVA) by two-dimensional echocardiography (2-D echo) requires a favorable parasternal acoustic window and depends on operator skill. Transthoracic volumetric 3-D echo allows reconstruction of multiple 2-D planes in any desired orientation and is not limited to parasternal acquisition, and could thus enhance the accuracy and feasibility of calculating MVA.

View Article and Find Full Text PDF

Background: Whether to perform valve replacement in patients with asymptomatic but severe aortic stenosis is controversial. Therefore, we studied the natural history of this condition to identify predictors of outcome.

Methods: During 1994, we identified 128 consecutive patients with asymptomatic, severe aortic stenosis (59 women and 69 men; mean [+/-SD] age, 60+/-18 years; aortic-jet velocity, 5.

View Article and Find Full Text PDF

This study investigated the use of artificial neural networks (ANN) for image segmentation and spatial temporal contour linking for the detection of endocardial contours on echocardiographic images. Using a backpropagation network, the system was trained with 279 sample regions obtained from eight training images to segment images into either tissue or blood pool region. The ANN system was then applied to parasternal short axis images of 38 patients.

View Article and Find Full Text PDF

The aims of this study were: (1) to measure noninvasively and near simultaneously myocardial blood flow, oxygen consumption, and contractile function and (2) to analyze myocardial energy expenditure and efficiency at rest and during dobutamine stress in normal humans. Dynamic and gated carbon-11 acetate positron emission tomography (PET) imaging was performed in 11 normal subjects. The initial uptake of (11)C-acetate was measured to estimate myocardial blood flow.

View Article and Find Full Text PDF