Publications by authors named "Poppe B"

Purpose: The self-shielding radiosurgery system ZAP-X consists of a 3 MV linear accelerator and eight round collimators. For this system, it is a common practice to perform the reference dosimetry using the largest 25 mm diameter collimator at a source-to-axis distance (SAD) of 45 cm with the PTW Semiflex3D chamber placed at a measurement depth of 7 mm in water. Existing dosimetry protocols do not provide correction for these measurement conditions.

View Article and Find Full Text PDF

Background: Modern radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), use complex fluence modulation strategies to achieve optimal patient dose distribution. Ensuring their accuracy necessitates rigorous patient-specific quality assurance (PSQA), traditionally done through pretreatment measurements with detector arrays. While effective, these methods are labor-intensive and time-consuming.

View Article and Find Full Text PDF

The U1 snRNP complex recognizes pre-mRNA splicing sites in the early stages of spliceosome assembly and suppresses premature cleavage and polyadenylation. Its dysfunction may precede Alzheimer's disease (AD) hallmarks. Here we evaluated the effects of a synthetic single-stranded cDNA (APT20TTMG) that interacts with U1 snRNP, in iPSC-derived neurons from a donor diagnosed with AD and in the SAMP8 mouse model.

View Article and Find Full Text PDF

: Nuclear fragmentation generates a diverse dosimetric environment in the path ofC ion beams. Concise parametrization of the beam's composition is paramount for determining key correction factors in clinical dosimetry. This study sets out to provide such a parametrization based on detailed Monte Carlo simulations of clinically relevantC beams.

View Article and Find Full Text PDF
Article Synopsis
  • The ZAP-X system is an innovative radiosurgical option using a 3 MV linear accelerator and varying collimator cone sizes aimed at early-stage treatments, which minimizes harm to healthy tissue.
  • A new 3 mm collimator cone has been developed for the ZAP-X, and the study aimed to assess the effectiveness of a commercial diode detector, the microSilicon, for measuring dosimetric properties and understanding the small field effects.
  • Results indicate that the microSilicon detector accurately characterizes the 3 mm beam's dosimetric properties, with high correlation between measurements from the detector and films, confirming its suitability for small field conditions in radiosurgery.
View Article and Find Full Text PDF

. The aim of this work is to investigate the response of the Roos chamber (type 34001) irradiated by clinical proton beams in magnetic fields..

View Article and Find Full Text PDF

Despite the low prevalence of each rare disease, the total burden is high. Patients with rare diseases encounter numerous barriers, including delayed diagnosis and limited access to high-quality treatments. In order to tackle these challenges, the European Commission launched the European Reference Networks (ERNs), cross-border networks of healthcare providers and patients representatives.

View Article and Find Full Text PDF

Erythrocytosis or polycythemia refers to a true or apparent increase in hemoglobin or hematocrit. When no etiology of erythrocytosis is identified, people are diagnosed with "idiopathic erythrocytosis" (IE). The identification of new contributing genes has recently improved the diagnostic workup of IE.

View Article and Find Full Text PDF

Phospholipase A/acyltransferase 3 (PLAAT3) is a phospholipid-modifying enzyme predominantly expressed in neural and white adipose tissue (WAT). It is a potential drug target for metabolic syndrome, as Plaat3 deficiency in mice protects against diet-induced obesity. We identified seven patients from four unrelated consanguineous families, with homozygous loss-of-function variants in PLAAT3, who presented with a lipodystrophy syndrome with loss of fat varying from partial to generalized and associated with metabolic complications, as well as variable neurological features including demyelinating neuropathy and intellectual disability.

View Article and Find Full Text PDF

Purpose: Germline pathogenic variants in CHEK2 confer moderately elevated breast cancer risk (odds ratio, OR ∼ 2.5), qualifying carriers for enhanced breast cancer screening. Besides pathogenic variants, dozens of missense CHEK2 variants of uncertain significance (VUS) have been identified, hampering the clinical utility of germline genetic testing (GGT).

View Article and Find Full Text PDF

The use of patient contact shielding provides an opportunity to reduce patient radiation exposure. Recently, the use has been the subject of controversy. The Radiation Protection Committee has published a recommendation on the use of patient radiation shields by considering the recent findings on dose savings but also the risks of incorrect use.

View Article and Find Full Text PDF
Article Synopsis
  • Hereditary neurologic diseases in adults have high clinical and molecular diversity, making diagnosis challenging; this study evaluates the effectiveness of exome sequencing (ES) in diagnosing these conditions.
  • Conducted at Ghent University Hospital from 2019 to 2022, the study tested 1,411 patients using multipanel ES, focusing on various neurological disorders and analyzing genetic variants across 725 genes.
  • A molecular diagnosis was achieved in 10% of cases, with the highest success rate in ataxia patients, revealing new genetic variants and highlighting that ES is a valuable diagnostic approach for adult-onset neurologic disorders.
View Article and Find Full Text PDF

Background And Purpose: As a part of the commissioning and quality assurance in proton beam therapy, lateral dose profiles and output factors have to be acquired. Such measurements can be performed with point detectors and are especially challenging in small fields or steep lateral penumbra regions as the detector's volume effect may lead to perturbations. To address this issue, this work aims to quantify and correct for such perturbations of six point detectors in small proton fields created via three different delivery techniques.

View Article and Find Full Text PDF

Purpose: The primary fluence of a proton pencil beam exiting the accelerator is enveloped by a region of secondaries, commonly called "spray". Although small in magnitude, this spray may affect dose distributions in pencil beam scanning mode e.g.

View Article and Find Full Text PDF

Purpose: Investigating and understanding of the underlying mechanisms affecting the charge collection efficiency (CCE) of vented ionization chambers under ultra-high dose rate pulsed electron radiation. This is an important step towards real-time dosimetry with ionization chambers in FLASH radiotherapy.

Methods: Parallel-plate ionization chambers (PPIC) with three different electrode distances were build and investigated with electron beams with ultra-high dose-per-pulse (DPP) up to 5.

View Article and Find Full Text PDF

Purpose: Monte Carlo (MC) simulation studies, aimed at evaluating the magnitude of tissue heterogeneity in I prostate permanent seed implant brachytherapy (BT), customarily use clinical post-implant CT images to generate a virtual representation of a realistic patient model (virtual patient model). Metallic artifact reduction (MAR) techniques and tissue assignment schemes (TAS) are implemented on the post-implant CT images to mollify metallic artifacts due to BT seeds and to assign tissue types to the voxels corresponding to the bright seed spots and streaking artifacts, respectively. The objective of this study is to assess the combined influence of MAR and TAS on MC absorbed dose calculations in post-implant CT-based phantoms.

View Article and Find Full Text PDF

. Point detector measurements in proton fields are perturbed by the volume effect originating from geometrical volume-averaging within the extended detector's sensitive volume and density perturbations by non-water equivalent detector components. Detector specific lateral dose response functions() can be used to characterize the volume effect within the framework of a mathematical convolution model, where() is the convolution kernel transforming the true dose profile() into the measured signal profile of a detector().

View Article and Find Full Text PDF

Background: In order to facilitate the diagnostic process for adult patients suffering from a rare disease, the Undiagnosed Disease Program (UD-PrOZA) was founded in 2015 at the Ghent University Hospital in Belgium. In this study we report the five-year results of our multidisciplinary approach in rare disease diagnostics.

Methods: Patients referred by a healthcare provider, in which an underlying rare disease is likely, qualify for a UD-PrOZA evaluation.

View Article and Find Full Text PDF

. To investigate the feasibility to train artificial neural networks (NN) to recover lateral dose profiles from detector measurements in a magnetic field..

View Article and Find Full Text PDF

With increasing investigation of the so-called FLASH effect, the need for accurate real time dosimetry for ultra-high dose rates is also growing. Considering the ultra-high dose-per-pulse (DPP) necessary to produce the ultra-high dose rates for investigations of the FLASH effect, real time dosimetry is a major challenge. In particular, vented ionization chambers, as used for dosimetry in conventional radiotherapy, show significant deviations from linearity with increasing DPP.

View Article and Find Full Text PDF

This study investigates the perturbation correction factors of air-filled ionization chambers regarding their depth and magnetic field dependence. Focus has been placed on the displacement or gradient correction factorPgr.Additionally, the shift of the effective point of measurementPeffthat can be applied to account for the gradient effect has been compared between the cases with and without magnetic field.

View Article and Find Full Text PDF

The RUBY head phantom in combination with the System QA insert MultiMet can be used for simultaneous point dose measurements at an isocentric and two off-axis positions. This study investigates the suitability of the system for systematic integral end-to-end testing of single-isocenter multiple target stereotactic treatments. Several volumetric modulated arc therapy plans were optimized on a planning CT of the phantom positioned in a stereotactic mask on the stereotactic treatment board.

View Article and Find Full Text PDF