Publications by authors named "Pooyan Sahbaee"

Objective: Among the advancements in computed tomography (CT) technology, photon-counting computed tomography (PCCT) stands out as a significant innovation, providing superior spectral imaging capabilities while simultaneously reducing radiation exposure. Its long-term stability is important for clinical care, especially longitudinal studies, but is currently unknown. This study sets out to comprehensively analyze the long-term stability of a first-generation clinical PCCT scanner.

View Article and Find Full Text PDF

Purpose: Evaluation of iodine quantification accuracy with varying iterative reconstruction level, patient habitus, and acquisition mode on a first-generation dual-source photon-counting computed tomography (PCCT) system.

Approach: A multi-energy CT phantom with and without its extension ring equipped with various iodine inserts (0.2 to 15.

View Article and Find Full Text PDF

With the introduction of spectral CT techniques into the clinic, the imaging capacities of CT were expanded to multiple energy levels. Due to a variety of factors, the acquired signal in spectral CT datasets is shared between these images. Conventional image quality metrics assume independence between images which is not preserved within spectral CT datasets, limiting their utility for characterizing energy selective images.

View Article and Find Full Text PDF

Background: Among the advancements in computed tomography (CT) technology, photon-counting computed tomography (PCCT) stands out as a significant innovation, providing superior spectral imaging capabilities while simultaneously reducing radiation exposure. Its long-term stability is important for clinical care, especially longitudinal studies, but is currently unknown.

Purpose: This study sets out to comprehensively analyze the long-term stability of a first-generation clinical PCCT scanner.

View Article and Find Full Text PDF

Dual-source photon-counting CT combines the high temporal resolution and high pitch of dual-source CT with the material quantification capabilities of photon-counting CT. It, however, results in cross-scatter that increases in severity with increased patient size and collimation. This cross-scatter must be corrected to ensure the removal of scatter artifacts and improve quantitative accuracy.

View Article and Find Full Text PDF

Objectives: The aim of this study was to assess the interreader reliability and per-RCC sensitivity of high-resolution photon-counting computed tomography (PCCT) in the detection and characterization of renal masses in comparison to MRI.

Materials And Methods: This prospective study included 24 adult patients (mean age, 52 ± 14 years; 14 females) who underwent PCCT (using an investigational whole-body CT scanner) and abdominal MRI within a 3-month time interval and underwent surgical resection (partial or radical nephrectomy) with histopathology (n = 70 lesions). Of the 24 patients, 17 had a germline mutation and the remainder were sporadic cases.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers studied a new type of CT scanner called Photon-counting CT (PCCT), which takes clearer pictures of blood vessels compared to regular CT scans.
  • They used a special machine to create images of different types of arteries, both still and moving, to see how well the PCCT worked.
  • The results showed that PCCT gives more accurate and consistent images, even when the heart is beating, which is great for checking heart health.
View Article and Find Full Text PDF

We evaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT). A cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned at five different heart rates (0, 60-100 bpm) with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were calculated for virtual monoenergetic images (VMI) at 50, 70, and 150 keV and iodine density maps at both diastole and systole.

View Article and Find Full Text PDF

Purpose: Advantages of virtual monoenergetic images (VMI) have been reported for dual energy CT of the head and neck, and more recently VMIs derived from photon-counting (PCCT) angiography of the head and neck. We report image quality metrics of VMI in a PCCT angiography dataset, expanding the anatomical regions evaluated and extending observer-based qualitative methods further than previously reported.

Methods: In a prospective study, asymptomatic subjects underwent contrast enhanced PCCT of the head and neck using an investigational scanner.

View Article and Find Full Text PDF

Cardiac CT is a useful tool for cardiovascular diagnostics that offers different acquisition modes, each with its advantages. The development of direct converting detector technology has resulted in the clinical translation of dual-source photon-counting CT. This takes advantage of the improved image quality at high heart rates from dual-source CT while making available spectral results for more precise material characterization and quantification.

View Article and Find Full Text PDF

Objective: Evaluation of image characteristics at ultra-low radiation dose levels of a first-generation dual-source photon-counting computed tomography (PCCT) compared to a dual-source dual-energy CT (DECT) scanner.

Methods: A multi-energy CT phantom was imaged with and without an extension ring on both scanners over a range of radiation dose levels (CTDI 0.4-15.

View Article and Find Full Text PDF

Objectives: We aimed to validate and test a prototype algorithm for automated dual-energy computed tomography (DECT)-based myocardial extracellular volume (ECV) assessment in patients with various cardiomyopathies.

Methods: This retrospective study included healthy subjects (n=9; 61±10 y) and patients with cardiomyopathy (n=109, including a validation cohort n=60; 68±9 y; and a test cohort n=49; 69±11 y), who had previously undergone cardiac DECT. Myocardial ECV was calculated using a prototype-based fully automated algorithm and compared with manual assessment.

View Article and Find Full Text PDF

Objectives: To evaluate the effectiveness of a novel artificial intelligence (AI) algorithm for fully automated measurement of left atrial (LA) volumes and function using cardiac CT in patients with atrial fibrillation.

Methods: We included 79 patients (mean age 63 ± 12 years; 35 with atrial fibrillation (AF) and 44 controls) between 2017 and 2020 in this retrospective study. Images were analyzed by a trained AI algorithm and an expert radiologist.

View Article and Find Full Text PDF

Background: Determination of the total number and size of all pulmonary metastases on chest CT is time-consuming and as such has been understudied as an independent metric for disease assessment. A novel artificial intelligence (AI) model may allow for automated detection, size determination, and quantification of the number of pulmonary metastases on chest CT.

Objective: To investigate the utility of a novel AI program applied to initial staging chest CT in breast cancer patients in risk assessment of mortality and survival.

View Article and Find Full Text PDF

Objectives: To evaluate the benefit of a prototype circulation time-based test bolus evaluation algorithm for the individualized optimal timing of contrast media (CM) delivery in patients undergoing coronary CT angiography (CCTA).

Methods: Thirty-two patients (62 ± 16 years) underwent CCTA using a prototype bolus evaluation tool to determine the optimal time-delay for CM administration. Contrast attenuation, signal-to-noise ratio (SNR), objective, and subjective image quality were evaluated by two independent radiologists.

View Article and Find Full Text PDF

Background: Low-dose computed tomography (LDCT) are performed routinely for lung cancer screening. However, a large amount of nonpulmonary data from these scans remains unassessed. We aimed to validate a deep learning model to automatically segment and measure left atrial (LA) volumes from routine NCCT and evaluate prediction of cardiovascular outcomes.

View Article and Find Full Text PDF

Purpose: To compare the performance of energy-integrating detector (EID) CT, photon-counting detector CT (PCCT), and high-resolution PCCT (HR-PCCT) for the visualization of coronary plaques and reduction of stent artifacts in a phantom model.

Materials And Methods: An investigational scanner with EID and PCCT subsystems was used to image a coronary artery phantom containing cylindrical probes simulating different plaque compositions. The phantom was imaged with and without coronary stents using both subsystems.

View Article and Find Full Text PDF

Background The role of CT angiography-derived fractional flow reserve (CT-FFR) in pre-transcatheter aortic valve replacement (TAVR) assessment is uncertain. Purpose To evaluate the predictive value of on-site machine learning-based CT-FFR for adverse clinical outcomes in candidates for TAVR. Materials and Methods This observational retrospective study included patients with severe aortic stenosis referred to TAVR after coronary CT angiography (CCTA) between September 2014 and December 2019.

View Article and Find Full Text PDF

Objectives: The aim of the study is to investigate the performance of artificial intelligence (AI) convolutional neural networks (CNN) in detecting lung nodules on chest computed tomography of patients with complex lung disease, and demonstrate its noninferiority when compared against an experienced radiologist through clinically relevant assessments.

Methods: A CNN prototype was used to retrospectively evaluate 103 complex lung disease cases and 40 control cases without reported nodules. Computed tomography scans were blindly evaluated by an expert thoracic radiologist; a month after initial analyses, 20 positive cases were re-evaluated with the assistance of AI.

View Article and Find Full Text PDF

Photon-counting CT detectors are the next step in advancing CT system development and will replace the current energy integrating detectors (EID) in CT systems in the near future. In this context, the performance of PCCT was compared to EID CT for three clinically relevant tasks: abdominal soft tissue imaging, where differentiating low contrast features is important; vascular imaging, where iodine detectability is critical; and, high-resolution skeletal and lung imaging. A multi-tiered phantom was imaged on an investigational clinical PCCT system (Siemens Healthineers) across different doses using three imaging modes: macro and ultra-high resolution (UHR) PCCT modes and EID CT.

View Article and Find Full Text PDF

Purpose: To evaluate the additional value of noninvasive artificial intelligence (AI)-based CT-derived fractional flow reserve (CT FFR), derived from triple-rule-out coronary CT angiography for acute chest pain (ACP) in the emergency department (ED) setting.

Materials And Methods: AI-based CT FFR from triple-rule-out CT angiography data sets was retrospectively obtained in 159 of 271 eligible patients (102 men; mean age, 57.0 years ± 9.

View Article and Find Full Text PDF

Rationale And Objectives: Research on implementation of artificial intelligence (AI) in radiology workflows and its impact on reports remains scarce. In this study, we aim to assess if an AI platform would perform better than clinical radiology reports in evaluating noncontrast chest computed tomography (CT) scans.

Materials And Methods: Consecutive patients who had undergone noncontrast chest CT were retrospectively identified.

View Article and Find Full Text PDF

Background: Artificial intelligence (AI) in diagnostic radiology is undergoing rapid development. Its potential utility to improve diagnostic performance for cardiopulmonary events is widely recognized, but the accuracy and precision have yet to be demonstrated in the context of current screening modalities. Here, we present findings on the performance of an AI convolutional neural network (CNN) prototype (AI-RAD Companion, Siemens Healthineers) that automatically detects pulmonary nodules and quantifies coronary artery calcium volume (CACV) on low-dose chest CT (LDCT), and compare results to expert radiologists.

View Article and Find Full Text PDF

Photon-counting computed tomography (CT) is a developing technology that has the potential to address some limitations of CT imaging and bring about improvements and potentially new applications to this field. Photon-counting detectors have a fundamentally different detection mechanism from conventional CT energy-integrating detectors that can improve dose efficiency, spatial resolution, and energy-discrimination capabilities. In the past decade, promising human studies have been reported in the literature that have demonstrated benefits of this relatively new technology for various clinical applications.

View Article and Find Full Text PDF