Purpose: To apply retinal nerve fiber layer (RNFL) optical texture analysis (ROTA) to investigate the prevalence, patterns, and risk factors of RNFL defects in patients with ocular hypertension (OHT) who showed normal optic disc and RNFL configuration in clinical examination, normal RNFL thickness on OCT analysis, and normal visual field (VF) results.
Design: Cross-sectional study.
Participants: Six hundred eyes of 306 patients with OHT.
Purpose: To compare the rates of peripapillary vessel density (pVD) loss and retinal nerve fibre layer (RNFL) thinning in normal tension glaucoma (NTG) and primary angle closure glaucoma (PACG).
Methods: Baseline age and severity-matched NTG and PACG eyes (75 eyes of 60 patients for each subtype) were observed longitudinally. All participants' RNFL thickness were measured by optical coherence tomography (OCT); pVD were measured by swept-source OCT-angiography (OCT-A) and quantified by a customised MATLAB program.
Purpose: To investigate the relationship of macular intercapillary area (ICA) with macular ganglion cell-inner plexiform layer (GCIPL) thickness and central visual field sensitivity (CVFS) in normal tension glaucoma (NTG).
Methods: Seventy-eight early NTG eyes, 33 moderate-to-severe NTG eyes and 75 normal control eyes were cross-sectional evaluated. All participants underwent swept-source optical coherence tomography angiography (OCT-A; DRI-OCT, Topcon, Tokyo, Japan).
Background: Whereas lowering the intraocular pressure (IOP) can slow optic nerve degeneration in glaucoma, many patients with glaucoma continue to develop progressive loss in vision despite a significant reduction in IOP. No treatment has been shown to be effective for neuroprotection in glaucoma. We set out to conduct a randomized controlled trial to investigate whether nicotinamide riboside (NR), a nicotinamide adenine dinucleotide precursor, is effective to slow optic nerve degeneration in patients with primary open-angle glaucoma (POAG).
View Article and Find Full Text PDFThis study compared the test-retest variabilities and measurement agreement of anterior chamber angle (ACA) dimensions measured by two anterior segment swept-source optical coherence tomography (SS-OCT)-the ANTERION (Heidelberg Engineering, Heidelberg, Germany) and CASIAII (Tomey, Nagoya, Japan). Thirty-eight subjects, 18 patients with primary angle closure and 20 healthy participants with open angles, were included. The mean age was 54.
View Article and Find Full Text PDFPurpose: To document the continuous circadian intraocular pressure (IOP) fluctuation using a contact lens sensor during normal daily activities, and to study the relationship between IOP fluctuation and disease progression in primary angle closure glaucoma (PACG) eyes.
Methods: Circadian IOP fluctuations were recorded by Sensimed Triggerfish sensors in 25 PACG eyes. The sensor output signals were smoothed using B-spline smoothing transform and described by functional data analysis.