Publications by authors named "Po-Hung Wu"

Among Group III-A metal monochalcogenides, gallium telluride (GaTe) is one of the less studied materials in terms of applications and optical characterization. For the temperature dependence of the energy transitions in GaTe, photoluminescence (PL) spectroscopy is commonly used, and photomodulated reflectance (PR) is yet to be reported. In this work, layered monoclinic GaTe single crystals were synthesized by the Bridgman technique and used for the investigation of the conduction band (CB) edge and free-exciton (FX) state transitions using PR spectroscopy.

View Article and Find Full Text PDF

Bone turnover assessment and monitoring are essential for chronic kidney disease (CKD)-associated bone care. Patients with CKD suffer from significantly elevated fracture risk due to abnormally high or low bone turnover, which requires diametrically opposite treatments informed by patient-specific bone turnover data. However, a reliable, accessible, non-invasive bone turnover assessment and monitoring tool remains an unmet clinical need.

View Article and Find Full Text PDF

Context: Roux-en-Y gastric bypass (RYGB) has deleterious effects on bone mass, microarchitecture, and strength. The skeletal effects of sleeve gastrectomy (SG), now the most commonly performed bariatric surgical procedure, are incompletely understood.

Objective: We examined changes in bone turnover, areal and volumetric bone mineral density (aBMD, vBMD), and appendicular bone microarchitecture and estimated strength after SG.

View Article and Find Full Text PDF

Context: Roux-en-Y gastric bypass (RYGB) has deleterious effects on bone mass, microarchitecture, and strength. Data are lacking on the skeletal effects of sleeve gastrectomy (SG), now the most commonly performed bariatric surgical procedure.

Objective: We examined changes in bone turnover, areal and volumetric bone mineral density (aBMD, vBMD), and appendicular bone microarchitecture and estimated strength after SG.

View Article and Find Full Text PDF

Introduction: Fracture risk is elevated in type 2 diabetes (T2D) despite normal or even high bone mineral density (BMD). Microvascular disease (MVD) is a diabetic complication, but also associated with other diseases, for example chronic kidney disease. We hypothesize that increased fracture risk in T2D could be due to increased cortical porosity (Ct.

View Article and Find Full Text PDF

Type 2 diabetes (T2D) has negative effects on skeletal health. A proposed mechanism of diabetic bone disease connects hyperlipidemia to increased bone marrow adiposity and decreased bone quality. Previous research on Type 1 diabetes reported positive associations between serum lipid levels and marrow adiposity, but no data exist for T2D.

View Article and Find Full Text PDF

The SnS/SnS heterostructure was fabricated by the chemical vapor deposition method. The crystal structure properties of SnS and SnS were characterized by X-ray diffraction (XRD) pattern, Raman spectroscopy, and field emission scanning electron microscopy (FESEM). The frequency dependence photoconductivity explores its carrier kinetic decay process.

View Article and Find Full Text PDF

Purpose Of Review: The relationships between bone vasculature and bone microstructure and strength remain incompletely understood. Addressing this gap will require in vivo imaging capabilities. We describe the relevant vascular anatomy of compact bone, review current magnetic resonance imaging (MRI)-based techniques that allow in vivo assessment of intracortical vasculature, and finally present preliminary studies that apply these techniques to investigate changes in intracortical vessels in aging and disease.

View Article and Find Full Text PDF

Mechanical unloading causes rapid loss of bone structure and strength, which gradually recovers after resuming normal loading. However, it is not well established how this adaptation to unloading and reloading changes with age. Clinically, elderly patients are more prone to musculoskeletal injury and longer periods of bedrest, therefore it is important to understand how periods of disuse will affect overall skeletal health of aged subjects.

View Article and Find Full Text PDF

Roux-en Y gastric bypass (RYGB) surgery is an effective treatment for obesity; however, it may negatively impact skeletal health by increasing fracture risk. This increase may be the result not only of decreased bone mineral density but also of changes in bone microstructure, for example, increased cortical porosity. Increased tibial and radial cortical porosity of patients undergoing RYGB surgery has been observed as early as 6 months postoperatively; however, local microstructural changes and associated biological mechanisms driving this increase remain unclear.

View Article and Find Full Text PDF

Purpose: To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring.

Methods: 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation.

View Article and Find Full Text PDF

Cortical bone microstructure deficits may increase fracture risk in individuals with cardiovascular disease and diabetes. High resolution peripheral quantitative computed tomography (HR-pQCT) enables in vivo microstructure characterization but is limited in its ability to visualize important biological features. We conducted histological analyses and HR-pQCT imaging of distal tibia bone samples from 6 donors with cardiovascular disease (CVD) and type 2 diabetes mellitus (T2D).

View Article and Find Full Text PDF

Purpose: Intra-procedural monitoring and post-procedural follow-up is necessary for a successful ablation treatment. An imaging technique which can assess the ablation geometry accurately is beneficial to monitor and evaluate treatment. In this study, we developed an automated ablation segmentation technique for serial low-dose, noisy ablation computed tomography (CT) or contrast-enhanced CT (CECT).

View Article and Find Full Text PDF

Objective: Significant weight loss following treatments for obesity undermines bone metabolism and increases bone turnover and fracture incidence. High resolution peripheral quantitative computed tomography (HR-pQCT) is widely used in skeletal heath assessment research to provide noninvasive bone parameter measurement (e.g.

View Article and Find Full Text PDF

Purpose: In adults with long-term HIV infection, low bone density and increased fracture risk have emerged as significant comorbidities. Our aim was to assess the association of exercise, nutrition, and medications with bone quality in adults with long-term HIV infection.

Methods: Forty-three adults with HIV infection were enrolled (median BMI 25.

View Article and Find Full Text PDF
Article Synopsis
  • Cortical bone porosity affects bone strength, but the biological factors influencing it are unclear, and both vessels and fat cells play a role in pore expansion.
  • Recent advancements combine dynamic contrast-enhanced MRI (DCE-MRI) and high-resolution peripheral QCT (HR-pQCT) to visualize these vessels in cortical bone, which hasn't been done before.
  • A study involving 19 older adults used this method to identify and quantify the presence of vessels in bone pores, examining characteristics like vessel volume fraction and density through advanced imaging techniques.*
View Article and Find Full Text PDF

Purpose: Deformable registration of ultrasound (US) and contrast enhanced computed tomography (CECT) images are essential for quantitative comparison of ablation boundaries and dimensions determined using these modalities. This comparison is essential as stiffness-based imaging using US has become popular and offers a nonionizing and cost-effective imaging modality for monitoring minimally invasive microwave ablation procedures. A sensible manual registration method is presented that performs the required CT-US image registration.

View Article and Find Full Text PDF

Purpose: Intra-procedural contrast-enhanced computed tomography (CECT) has been proposed to monitor the growth of thermal ablations. The primary challenge with multiple CT acquisitions is reducing radiation dose while maintaining sufficient image quality. The purpose of this study was to evaluate the feasibility of applying local highly constrained backprojection reconstruction (HYPR-LR) on periodic CECT images acquired with low-dose protocols, and to determine whether the ablations visible on CT were commensurate to gross pathology.

View Article and Find Full Text PDF

Intra-procedural contrast-enhanced CT (CECT) has been proposed to evaluate treatment efficacy of thermal ablation. We hypothesized that contrast material delivered concurrently with thermal ablation may become trapped in the ablation zone, and set out to determine whether such an effect would impact ablation visualization. CECT images were acquired during microwave ablation in normal porcine liver with: (A) normal blood perfusion and no iodinated contrast, (B) normal perfusion and iodinated contrast infusion or (C) no blood perfusion and residual iodinated contrast.

View Article and Find Full Text PDF

Salient region detection is useful for several image-processing applications, such as adaptive compression, object recognition, image retrieval, filter design, and image retargeting. A novel method to determine the salient regions of images is proposed in this paper. The L₀ smoothing filter and principle component analysis (PCA) play important roles in our framework.

View Article and Find Full Text PDF

In this work, the effects of crystallization and non-lattice oxygen atoms on the Cu(x)O-based memory device are investigated. The 150 degrees C-deposited Cu(x)O film possesses a larger amount of non-lattice oxygen atoms than those deposited at the higher temperatures, leading to the formation of AIOy interface layer during the sputtering deposition of Al top electrode. Resistive switching occurring within the interface layer is easily controlled, so the set and reset voltages are decreased.

View Article and Find Full Text PDF
Article Synopsis
  • A new white-rot fungus, Cerrena sp. WR1, was identified and shown to produce a highly active laccase enzyme (Lcc3) with a maximum activity of 202,000 U l⁻¹, and its gene was successfully cloned.
  • Kinetic studies revealed Lcc3 has varying affinities for different substrates, with a high thermal stability (T(m) at 73.9°C) and significant activity retention even in high ethanol concentrations.
  • The laccase demonstrated the ability to degrade lignin in kraft paper and effectively decolorize synthetic dyes, highlighting its potential industrial applications.
View Article and Find Full Text PDF

A fed-batch culture strategy for the production of recombinant Escherichia coli cells anchoring surface-displayed transglucosidase for use as a whole-cell biocatalyst for alpha-arbutin synthesis was developed. Lactose was used as an inducer of the recombinant protein. In fed-batch cultures, dissolved oxygen was used as the feed indicator for glucose, thus accumulation of glucose and acetate that affected the cell growth and recombinant protein production was avoided.

View Article and Find Full Text PDF

A surface anchoring motif using the ice nucleation protein (INP) of Xanthomonas campestris pv. campestris BCRC 12,846 for display of transglucosidase has been developed. The transglucosidase gene from Xanthomonas campestris pv.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session1cc0v1jf8f7srbmcqefb3lpq1i1m7ajq): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once