J Orthop Surg Res
November 2023
Background: Various factors influence treatment and outcomes in tibial plateau fractures. Bone defects are among them. Many materials have been proposed to address this problem: allograft, bone-cements and various bone substitutes (BSM).
View Article and Find Full Text PDFMusculoskelet Surg
April 2021
Introduction: We use external elbow joint fixator (FE-F4) for fracture and dislocation of the ulnohumeral joint to evaluate the early articular mobilization maintaining concentric reduction, protecting the osteoligamentous reconstruction and avoiding postoperative stiffness.
Materials And Methods: Thirty-two patients (13 men and 19 women) were treated with FE-F4: 7 simple dislocations (21.9%), 15 distal humerus fractures (46.
Unlabelled: The background and the aim of the work: The Department of Orthopedics and Traumatology of the "Carlo Poma" Hospital (Social Territorial Health Authority of Mantova), has pointed out in 2017, through the questionnaires survey over the citizens satisfaction, an appreciation decrease compared to the previous years. The obtained data were not sufficiently explanatory of the reasons for that kind of deterioration and also not enough specific to define possible corrective measures. The aim of this work was to identify the patients' perception regarding the hospitalization phases (from booking to follow up), taking into account five kind of operations and pathologies: 1st knee, shoulder and tibio-talar arthroscopy; 2nd hip and knee prosthesis; 3rd upper limb traumatology; 4th lower limb traumatology and 5th orthogeriatrics.
View Article and Find Full Text PDFMusculoskelet Surg
December 2016
Purpose: Ten percentage of all ankle fractures sustain an associated syndesmotic injury. TightRope is a relatively new technique for syndesmosis fixation, characterized by a non-absorbable FibreWire held tight between two cortical metal buttons. The purpose of this study was to evaluate the results obtained with the use of this device.
View Article and Find Full Text PDFThe authors report their experience of treating complex elbow fracture-dislocations in elderly people, using a minimally-invasive approach with a new articulated external fixator that is associated with minimal internal fixation. The clinical results for 19 patients are presented according to outcome factors, such as range of motion, pain and function, rate and type of complications, and reoperation rate. The results indicate that this treatment strategy should be considered as a good alternative to other treatment options reported in the literature, including conservative treatment, ORIF with angular stable plates and total elbow arthroplasty.
View Article and Find Full Text PDFBackground: Knee dislocation is a severe but relatively uncommon injury caused by violent trauma that can result in long-term complications, such as arthrofibrosis, stiffness, instability, and pain. Perhaps owing in part to its rarity, treatment of this injury is controversial. We therefore describe a treatment approach for these complex cases involving a novel dynamic knee external fixator.
View Article and Find Full Text PDFPercutaneous vertebroplasty (PVP) is a minimally invasive, image-guided procedure consisting of an injection of acrylic cement into a vertebral body to reinforce the compressed segment and achieve pain relief. The use of PVP is a minimally invasive option in the treatment of osteoporotic or metastatic vertebral collapses. Our personal experience, using a CT-guided technique, confirms the efficacy and safety of PVP with a lower risk for complications compared with conventional fluoroscopic approaches because of a precise placement of the instruments in the vertebral body and an early detection of small cement leakages.
View Article and Find Full Text PDFPurpose: To assess the reliability of MRI and scintigraphy with 99mTc-HMPAO-labelled granulocytes in the diagnosis of bone infection.
Materials And Methods: Between November 2001 and November 2003, 25 patients (16 men and 9 women; age range 22-72 years; mean age 48 years) with suspected bone infection were evaluated. The lower limbs were more frequently involved (20/25 cases).
Purpose: To compare the manual measurements of lower limbs on digital images with those obtained with dedicated software.
Materials And Methods: Forty patients with a clinical suspicion of lower limb deformity were enrolled. Eighty digital radiographs were produced with a remote-controlled radiography system (Philips Omnidiagnost).
We gave a single fraction of 750 cGy preoperatively (within 16 h of surgery) to 143 patients prior to total hip arthroplasty. The patients were evaluated for heterotopic ossification at 1, 3 and 6 months. The preoperative radiation did not affect the surgical procedure.
View Article and Find Full Text PDFAn Orthofix monolateral axial external fixator was used to treat 31 patients with non-union of the humeral shaft, 30 of whom had been previously treated surgically. In seven cases the non-union was hypertrophic and one of these cases had been treated by simple fixation anol compression, the others by fixation, bone grafting and decortication; in 20 cases the non-union was hypotrophic and had been treated by fixation and decortication with bone grafting. The remaining four cases had septic non-union, treated by debridement of the focus of infection and fixation, followed in three cases by a bone graft and osteomuscular decortication once the infection had been eradicated.
View Article and Find Full Text PDFThe authors report 40 patients affected with diaphyseal fracture of the humerus treated by dynamic axial fixator (FAD Orthofix). Minimum follow-up was 2 years. A clinical and radiographic retrospective study was conducted with the purpose of verifying the validity of external fixation as treatment of choice in diaphyseal fractures of the humerus.
View Article and Find Full Text PDFRev Chir Orthop Reparatrice Appar Mot
September 1995
Purpose Of The Study: The aim of this short study is to highlight the role of the hemicallotasis method in correcting genu varum associated with osteoarthritis.
Material And Method: 160 cases are described. The first step was to apply a Dynamic Axial Fixator (DAF) with a lockable ball joint.
Chir Organi Mov
September 1979
The aetiology and pathogenesis of wide loss of bony tissue are discussed. Methods of treatment are described. Five cases thus treated and cured are reported.
View Article and Find Full Text PDF