Publications by authors named "Pixue Gong"

A new multifactor analysis assessment strategy was developed for evaluating, optimizing, and comparing analytical techniques for acrylamide in frying oils. Based on five indices (absolute recovery, absolute matrix effect, the intensity of the full ion scan, and the precursor ion scan to m/z 184 and m/z 241), the proposed strategy was performed with radar analysis, relative contribution analysis, and the entropy-weighted technique for order performance by similarity to ideal solution analysis. Two novel methods based on quick, easy, cheap, effective, rugged, and safe extraction methodology and gel permeation chromatography-liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry have been developed for the analysis of acrylamide in frying oils.

View Article and Find Full Text PDF

A method for the determination of vitamin K and vitamin K in modulation milk powder was developed by high performance liquid chromatography (HPLC) coupled with post-column reduction. The samples were dissolved in water, lipase hydrolyzed, saponified with 2.5 mol/L sodium hydroxide solution and ethanol solution, extracted with -hexane, and dissolved in methanol after concentration.

View Article and Find Full Text PDF

A method was developed for the determination of diazepam in aquatic products by pass-through solid phase extraction-ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The analyte was extracted with acetonitrile directly and purified on a Prime HLB solid phase extraction column (60 mg/3 mL). The separation was performed on an Acquity UPLC BEH C column (100 mm×2.

View Article and Find Full Text PDF

This study established a novel flow injection (FI) methodology for the determination of phenol in aqueous samples based on luminol chemiluminescence (CL) detection. The method was based on the inhibition that phenol caused on the hemin-catalysed chemiluminescence reaction between luminol and hydrogen peroxide in alkaline solution. Optimum conditions and possible mechanisms have been investigated.

View Article and Find Full Text PDF

A sensitive flow injection (FI) chemiluminescence (CL) method was developed for the determination of trace amounts of progesterone. This method was based on the luminescent properties of the tris(1,10-phenanthroline) ruthenium(II) - potassium permanganate (KMnO4 ) - progesterone in acidic medium sensitized by Na2 SO3 . With the peak height as a quantitative parameter applying optimum conditions, the relative CL intensity was linear with progesterone concentration in the range of 1.

View Article and Find Full Text PDF