Compliant mechanisms have gained an increasing interest in recent years, especially in relation to the possibility of using 3D printers for their production. These mechanisms typically find applications in precise positioning systems of building robotic devices or in sensing where they can be used to characterize displacement. Three-dimensional printing with PLA materials allows fiber optic-based sensors to be incorporated into the structures of properly designed compliant mechanisms.
View Article and Find Full Text PDFThis article presents an attempt to determine the effect of the MXene phase addition and its decomposition during sintering with the use of the spark plasma sintering method on mechanical properties and residual stress of silicon carbide based composites. For this purpose, the unreinforced silicon carbide sinter and the silicon carbide composite with the addition of 2 wt.% of TiCT were tested.
View Article and Find Full Text PDFPurpose: Bone conduction stimulation applied on the otic capsule may be used in a conductive hearing loss treatment as an alternative to the bone conduction implants in clinical practice. A finite element study was used to evaluate the force amplitude and direction needed for the stimulation.
Methods: A finite element model of a female temporal bone with a precisely reconstructed cochlea was subjected to a harmonic analysis assuming two types of stimulation.
The effect of different stapes prostheses on the basilar membrane (BM) motion was determined. To that end, a three dimensional finite element (FE) model of the passive human cochlea was developed. Passive responses of the BM were found based on coupled fluid-structure interactions between the cochlear solid structures and the scala fluids.
View Article and Find Full Text PDFBiomech Model Mechanobiol
November 2013
Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner.
View Article and Find Full Text PDF