Introduction: Intraoperative assessment of stone size is crucial for the successful and safe extraction of stones. The first automatically fixating measuring stone basket prototype showed a mismatch between the steel spring and the nitinol basket; therefore, to improve this prototype, the steel spring was replaced with a nitinol spring and a modified scale was implemented on the basket handle for accurate intraoperative stone size measurement.
Methods: The proposed tipped basket was composed of nitinol.
Introduction: Endoscopic treatment of ureter stones and renal calculi relies on the surgeon's estimation of the stone size for both lithotripsy and removal of stones or stone fragments. We therefore compared precision and reliability of the endoscopic estimation of stone size by the surgeon with measurements on a scale on a stone basket.
Materials And Methods: Two surgeons (one high experienced and one low experienced) first estimated, then measured the size of 12 stones differing in size and color using different stone baskets (2.
Background: Complications after endoscopic retrieval of kidney and ureter stones are obviously related to the size of the stones as well as the experience of the surgeon and other factors. During the procedure it is sometimes difficult for surgeons to estimate stone size and therefore give prognostic advises. The visual perception of the stone size depends on the shape, colour, distance to the renoscope and dilatation of the ureter.
View Article and Find Full Text PDFThe double-J stents used today for palliative artificial urinary diversion very often show extreme formation of encrustations, even a short time after implantation. Despite increased scientific material development, the complication rate has not really been strongly influenced. Grant-aided by the German Federal Ministry of Education and Research, we chose a new interdisciplinary and translational approach by coating standard stent materials with plasma-deposited amorphous diamond-like carbon.
View Article and Find Full Text PDFDiamond-like carbon is a promising surface coating for biomedicinal implants like coronary stents or hip joints. Before widespread clinical use of this material, its biocompatibility has to be thoroughly assessed. Cells likely to encounter a diamond-like coated implant in the human body are cells of the monocytic lineage.
View Article and Find Full Text PDFZentralbl Veterinarmed A
November 1999
Monitoring training by measuring blood lactate content is a well-known procedure in sports physiology. Because of the difficulties in standardizing a test procedure in field studies, this method is fraught with considerable problems when applying it to race horses. The aim of the present study was to develop a test procedure which is able to give evidence about the training state of different race horses after nonidentical test-loads.
View Article and Find Full Text PDFZentralbl Veterinarmed A
July 1998
During training, in 10 trotters, blood samples from the vena jugularis were taken before and after a heat with 80% of maximum capability as well as in the recovery period. Lactic acid concentration and pH-value, haematocrit and haemoglobin content, as well as protein concentration and osmolality were measured. With the exception of protein concentration, the time course of the values during the recovery could be described by simple mathematical models (biexponential or exponential equations).
View Article and Find Full Text PDF