Introduction: While people with diabetes (PWD)'s experiences with their insulin delivery systems (IDS) are frequently reported in clinical trials, few real-world data exist on the subject. This study aimed to assess the real-world experience and satisfaction with IDS in PWD.
Methods: This cross-sectional survey of PWD treated with tubed or tubeless insulin pumps, hybrid closed loop (HCL) systems, or multiple daily injections (MDI) for at least 3 months ran from 4 to 16 May 2023.
The natural history of type 1 diabetes (T1D) evolves from stage 1 (islet autoimmunity with normoglycemia; ICD-10 diagnostic code E10.A1) to stage 2 (autoimmunity with dysglycemia; E10.A2) and subsequent clinical stage 3 (overt hyperglycemia), which is commonly the first time of referral.
View Article and Find Full Text PDFAim: Although newer technologies of insulin delivery in type 1 diabetes have facilitated an improvement in glycaemic control the risk of hypoglycaemia remains a threat. Therefore, it is important to define the thresholds of glycaemic variability below which the risk of hypoglycaemia can be eliminated or at least minimized.
Methods: Randomized controlled trials conducted from 2017 to 2023 comparing Sensor-Augmented-Pumps and Augmented Insulin Delivery Systems (n = 16 and 22 studies, respectively) were selected.
New therapeutic approaches to treat type 1 diabetes mellitus relies on pancreatic islet transplantation. Here, developing immuno-isolation strategies is essential to eliminate the need for systemic immunosuppression after pancreatic islet grafts. A solution is the macro-encapsulation of grafts in semipermeable matrixes with a double function: separating islets from host immune cells and facilitating the diffusion of insulin, glucose, and other metabolites.
View Article and Find Full Text PDFObjective: Continuous glucose monitoring (CGM) combined with continuous subcutaneous insulin infusion (CSII) achieves better glycemic control than multi-injection therapy in people with type 2 diabetes. The effectiveness of closed-loop therapy needs to be further evaluated in this population.
Research Design And Methods: The study objective was to measure the impact of a hybrid closed-loop device (DBLG1) compared with CSII + CGM on glycemic control in people with type 2 diabetes previously treated with CSII.
Background: The prediction of the individual insulin needs may facilitate the initiation of insulin therapy. Our aim was to explore the relationships between body weight, sex, and daily amounts of insulin delivered by a hybrid closed-loop system.
Methods: We performed a retrospective data collection of all consenting adult patients with type 1 diabetes who were equipped in Europe with the Diabeloop Generation 1 (DBLG1) hybrid closed-loop insulin delivery device between March 1, 2021 and February 28, 2023.
Diabetes Technol Ther
June 2024
Islet transplantation improves metabolic control in patients with unstable type 1 diabetes. Clinical outcomes have been improving over the last decade, and the widely used beta-score allows the evaluation of transplantation results. However, predictive pre-transplantation criteria of islet quality for clinical outcomes are lacking.
View Article and Find Full Text PDFThe introduction of automated insulin delivery (AID) systems has enabled increasing numbers of individuals with type 1 diabetes (T1D) to improve their glycemic control largely. However, use of AID systems is limited due to their complexity and costs associated. The user must wear both a continuously monitoring glucose system and an insulin infusion pump.
View Article and Find Full Text PDFDiabetes Care
October 2023
According to the latest statistics, more than 537 million people around the world struggle with diabetes and its adverse consequences. As well as acute risks of hypo- or hyper- glycemia, long-term vascular complications may occur, including coronary heart disease or stroke, as well as diabetic nephropathy leading to end-stage disease, neuropathy or retinopathy. Therefore, there is an urgent need to improve diabetes management to reduce the risk of complications but also to improve patient's quality life.
View Article and Find Full Text PDFAim: To investigate sleep apnoea prevalence, factors influencing severity, and associations between sleep apnoea severity and micro-/macrovascular complications in a large population of patients with type 1 diabetes.
Materials And Methods: This French multicentre prospective cohort study was conducted between July 2016 and June 2020. Adults with type 1 diabetes using an insulin pump were eligible.
Aim: The Diabeloop Generation 1 (DBLG1) system is an interoperable hybrid closed-loop solution that was commercialized in Germany in March 2021. We report the longitudinal glycaemic outcomes among the first 3706 users in a real-world setting.
Methods: We performed a retrospective data collection of all consenting adult patients with type 1 diabetes who were equipped in Germany with the DBLG1 system before 30 April 2022, and with a minimum 14 days of closed-loop usage.
The aim of this study was to better characterise whether sleep habits, eating schedule and physical activity in real-life are associated with glycaemic control in patients with type 2 diabetes. A total of 28 patients (aged 60 years [58; 66], 54% female) with type 2 diabetes treated with basal-bolus insulin therapy administered by insulin pumps were analysed. Glycaemic data measured by Flash Glucose Monitor System, physical activity and sleep data measured by accelerometer, and meal schedules were simultaneously collated with insulin pump administration data, for 7 days in real-life.
View Article and Find Full Text PDFBackground: Automated insulin delivery is an efficient treatment for patients with type 1 diabetes. Little is known on its impact on patients with excessive time in hypoglycaemia.
Methods: We performed a post hoc analysis of three randomized control trials that used the DBLG1 (Diabeloop Generation 1) hybrid closed-loop solution.
Background: Support programs are provided to people with diabetes to help them manage their disease. However, adherence to and persistence in support programs are often low, making it difficult to demonstrate their effectiveness.
Aim: To identify the determinants of patients' perceived interest in diabetes support programs because it may be a powerful determinant of effective participation in such programs.
Cystic fibrosis-related diabetes (CFRD) is a common complication of cystic fibrosis (CF), and restoring metabolic control in these patients may improve their management after lung transplantation. In this multicenter, prospective, phase 1-2 trial, we evaluate the feasibility and metabolic efficacy of combined pancreatic islet-lung transplantation from a single donor in patients with CFRD, terminal respiratory failure, and poorly controlled diabetes. Islets were infused via the portal vein under local anesthesia, 1 week after lung transplantation.
View Article and Find Full Text PDFBackground: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data.
Methods: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia.
Background: Time in range (TIR) goals are rarely met in children with type 1 diabetes, except at the cost of increased hypoglycaemia episodes. Our objective was to evaluate the safety and efficiency of the Diabeloop DBL4K (Diabeloop, Grenoble, France) hybrid closed-loop system in prepubescent children.
Methods: We did a multicentre, open-label, randomised, controlled, non-inferiority, two-session crossover study in the paediatric endocrinology departments of three university hospitals in France and Belgium.