Surface electromyography techniques are widely used in field of motion analysis and ergonomics combining precise muscular activation assessment with low-invasiveness and wearability. The aim of this investigation is to identify the myoelectrical manifestations of fatigue and to compare the effectiveness of sEMG-based quantitative indices for fatigue assessment. The investigated indexes are the ARV and RMS signal amplitudes, the mean frequency, the median frequency, the Dimitrov index, the instantaneous mean frequency and Wavelet distribution-based 51 index.
View Article and Find Full Text PDFObjective: We propose a procedure for calibrating 4 parameters governing the mechanical boundary conditions (BCs) of a thoracic aorta (TA) model derived from one patient with ascending aortic aneurysm. The BCs reproduce the visco-elastic structural support provided by the soft tissue and the spine and allow for the inclusion of the heart motion effect.
Methods: We first segment the TA from magnetic resonance imaging (MRI) angiography and derive the heart motion by tracking the aortic annulus from cine-MRI.
The current guidelines for the ascending aortic aneurysm (AsAA) treatment recommend surgery mainly according to the maximum diameter assessment. This criterion has already proven to be often inefficient in identifying patients at high risk of aneurysm growth and rupture. In this study, we propose a method to compute a set of local shape features that, in addition to the maximum diameter , are intended to improve the classification performances for the ascending aortic aneurysm growth risk assessment.
View Article and Find Full Text PDFSeveral approaches have been used to devise a model of the human tibiofemoral joint for embedment in lower limb musculoskeletal models. However, no study has considered the use of cadaveric 6 × 6 compliance (or stiffness) matrices to model the tibiofemoral joint under normal or pathological conditions. The aim of this paper is to present a method to determine the compliance matrix of an ex vivo tibiofemoral joint for any given equilibrium pose.
View Article and Find Full Text PDFThe paper deals with the comparison between a high-end marker-based acquisition system and a low-cost marker-less methodology for the assessment of the human posture during working tasks. The low-cost methodology is based on the use of a single Microsoft Kinect V1 device. The high-end acquisition system is the BTS SMART that requires the use of reflective markers to be placed on the subject's body.
View Article and Find Full Text PDFSurg Laparosc Endosc Percutan Tech
April 2015
Introduction: Complications and challenges arising from the intraoperative double-stapling technique are seldom reported in colorectal surgery literature. Partial or full-thickness rectal injuries can occur during the introduction and the advancement of the circular stapler along the upper rectum. The aim of this study is to address some of these issues by designing and optimizing a "phantom" anvil manufactured to overcome difficulties throughout the rectal introduction and advancement of the circular stapler for the treatment of benign and malignant colon disease.
View Article and Find Full Text PDFInt J Oral Maxillofac Implants
November 2011
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of the pickup impression technique using a modular individual tray (MIT) and using a standard individual tray (ST) for multiple internal-connection implants. The roles of both materials and geometric misfits were considered.
Materials And Methods: First, because the MIT relies on the stiffness and elasticity of acrylic resin material, a preliminary investigation of the resin volume contraction during curing and polymerization was done.