Publications by authors named "Pier Giorgio Golzio"

Cardiac resynchronization therapy (CRT) was shown to improve cardiac function, reduce heart failure hospitalizations, improve quality of life and prolong survival in patients with severe left ventricular dysfunction and intraventricular conduction disturbances, mainly left bundle branch block, on optimal medical therapy with ACE-inhibitors, β-blockers and mineralocorticoid receptor antagonists up-titrated to maximum tolerated evidence-based doses. CRT can be achieved by means of pacemaker systems (CRT-P) or devices with defibrillation capabilities (CRT-D). CRT-Ds offer an undoubted advantage in the prevention of arrhythmic death, but such an advantage may be of lesser degree in nonischemic heart failure etiologies.

View Article and Find Full Text PDF

Background: 'Idiopathic' lead macrodislodgement may be due to Twiddler's syndrome depending on active twisting of pulse generator within subcutaneous pocket. All leads are involved, at any time from implantation, and frequently damaged. In the past few years, a reel syndrome was also observed: retraction of pacemaker leads into pocket without patient manipulation, owing to lead circling the generator.

View Article and Find Full Text PDF

Purpose: Left atrial volume index (LAVI) is a predictor of heart failure and adverse events, irrespective of left ventricular systolic function. The role of LAVI in the prediction of appropriate implantable cardioverter-defibrillator (ICD) therapies is currently unclear and was the focus of this study.

Methods: Consecutive heart failure patients with ischaemic (ICM) or idiopathic (DCM) aetiology receiving ICD for primary prevention were included.

View Article and Find Full Text PDF

Aim: Obesity is associated with an increased cardiovascular risk. This study aimed to assess the role of echocardiography in the early detection of subclinical cardiac abnormalities in a cohort of obese patients with a preserved ejection fraction (EF) undergoing bariatric surgery.

Methods And Results: Forty consecutive severely obese patients (body mass index≥35 kg/m2) referring to our center for bariatric surgery were enrolled in this prospective cohort study.

View Article and Find Full Text PDF

Background: Recent studies suggest that atrioventricular (AV) conduction may recover after pacemaker (PM) implantation following transcatheter aortic valve replacement (TAVR), but little is known about long-term follow-up of such patients.

Objective: The purpose of this study was to evaluate the long-term percentage of right ventricular pacing in patients who underwent TAVR and required PM implantation stratified based on the indication for permanent pacing.

Methods: Retrospective analysis of all consecutive patients who underwent TAVR from February 2008 to August 2019 at 3 centers was performed.

View Article and Find Full Text PDF

The subcutaneous implantable cardioverter defibrillator (S-ICD) is an alternative to transvenous ICD in patients who do not need cardiac pacing. We report the case of a young isometric athlete who received S-ICD for primary prevention of sudden death. Lead dislodgement and myopotential noise oversensing during isometric training led to inappropriate shock, and a surgical revision was performed.

View Article and Find Full Text PDF

Background: Diuretic resistance portends a poor prognosis in acute heart failure, especially in advanced stages. Early identification of a poor response to diuretics may help to improve treatment and outcomes. Spot natriuresis (UNa) at 2 h from the start of intravenous furosemide has been proposed as an early indicator of diuretic response.

View Article and Find Full Text PDF

Inadvertent malposition of a pacemaker lead in the left ventricle is uncommon, but it should not be misdiagnosed. We report the case of a 68-year-old woman with symptomatic sick-sinus syndrome requiring pacemaker implantation. Shortly afterwards the lead was extracted and a new pacemaker was contralaterally implanted due to pocket hematoma and suspected lead fracture.

View Article and Find Full Text PDF

Aims: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men.

Methods And Results: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted.

View Article and Find Full Text PDF

Aims: A sub-analysis of the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) Registry to evaluate the clinical impact of antithrombotic (AT) on transvenous lead extraction (TLE) safety and efficacy.

Methods And Results: ELECTRa outcomes were compared between patients without AT therapy (No AT Group) and with different pre-operative AT regimens, including antiplatelets (AP), anticoagulants (AC), or both (AP + AC). Out of 3510 pts, 2398 (68%) were under AT pre-operatively.

View Article and Find Full Text PDF

Background: Diuretic resistance is a common issue in patients with acute decompensation of advanced chronic heart failure (ACHF). The aim of this trial was to compare boluses and continuous infusion of furosemide in a selected population of patients with ACHF and high risk for diuretic resistance.

Methods: In this single-centre, double-blind, double-dummy, randomized trial, we enrolled 80 patients admitted for acute decompensation of ACHF (NYHA IV, EF ≤ 30%) with criteria of high risk for diuretic resistance (SBP ≤ 110 mmHg, wet score ≥ 12/18, and sodium ≤ 135 mMol/L).

View Article and Find Full Text PDF

Background: Finding of intracardiac lead masses in patients with cardiac implantable electronic devices remains controversial, as such masses have been observed in cases of exclusively local infections whereas they have not been recognized in patients with positive cultures of intravascular lead fragments. In this study, we aim to describe the prevalence of intracardiac lead masses in true asymptomatic patients with cardiac implantable electronic devices, to identify their predictive factors and to define their prognostic impact at long-term follow-up.

Methods: Seventy-eight consecutive patients admitted over a 6-month period for elective generator replacement without clinical evidence of infection were evaluated by transthoracic and transesophageal echocardiography and prospectively followed at in-clinic follow-up visits.

View Article and Find Full Text PDF

: Cardiac implantable electronic device (CIED) implantation has greatly increased, with an associated exponential increase in CIED infections (CDIs). Cardiac device related infective endocarditis (CDRIE) has high morbidity and mortality: approximately 10-21%. Therefore, a prompt diagnosis and radical treatment of CDRIE are needed; transvenous lead extraction (TLE) is the mainstay for the complete healing, even if associated with wide logistic problems, high therapeutic costs and high mortality risk for patients.

View Article and Find Full Text PDF

Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and associated with high-dose x-ray exposure. We present the technique in which an electromagnetic navigation system (MediGuideTM, St. Jude Medical) and an electroanatomical three-dimensional mapping system (EnSite NavX, St Jude Medical) are usefully combined for implanting implantable cardioverter defibrillator CRT devices with strong reduction of x-ray exposure, and for targeting the most delayed regions in the activation maps avoiding scars for optimal CRT response.

View Article and Find Full Text PDF
Article Synopsis
  • * Women tend to be referred for catheter ablation later than men, resulting in poorer treatment outcomes, although they show better responses to cardiac resynchronization therapy.
  • * The review will explore differences in causes, clinical profiles, and complications related to gender, along with potential mechanisms and practical considerations for procedures.
View Article and Find Full Text PDF
Article Synopsis
  • Transvenous lead extraction (TLE) of the Starfix coronary sinus lead can be difficult due to issues like undeployed fixation lobes and venous blockages.
  • A case involving a 78-year-old male with infective endocarditis highlighted the challenges faced during TLE, especially when the lead tip is located in hard-to-reach areas.
  • Modifications to standard delivery techniques, along with the use of experienced operators and non-conventional methods, may improve the chances of successful lead removal while minimizing surgical risks.
View Article and Find Full Text PDF

A 26-year-old patient was diagnosed as having chronic intestinal pseudo-obstruction with manometric and histopathologic features suggestive of an intestinal myopathy. Histology was characterized by smooth muscle degeneration without inflammatory or immune cells. The severe gut dysfunction required full parenteral nutritional support.

View Article and Find Full Text PDF

The use of cardiac implantable electronic devices (CIED) increased over time, followed by rise of CIED-related complications, mainly infections and malfunctions. A clear diagnosis of CIED infection is of pivotal importance. When infection is confirmed, transvenous lead extraction (TLE) becomes mandatory, with associated risks and mortality.

View Article and Find Full Text PDF

Aims: Actual rates of lead vegetations (LVs) in cardiovascular device infections (CDI) are debated in this study. The aim of this study is to characterize prevalence and risk factors of LV in patients with CDI treated with lead extraction (LE).

Methods And Results: Between 2003 and 2011, 293 leads were extracted from 136 patients (age 70.

View Article and Find Full Text PDF

In children, intracardiac loops are created to avoid a lead's fracture due to rapid body growth. Selective site pacing needs the insertion of two 4.1 Fr lumenless leads that do not allow direct manoeuvrability and should be extracted when tension on the lead occurs.

View Article and Find Full Text PDF