Purpose: To quantify inter-institute variability of Knowledge-Based (KB) models for right breast cancer patients treated with tangential fields whole breast irradiation (WBI).
Materials And Methods: Ten institutions set KB models by using RapidPlan (Varian Inc.), following previously shared methodologies.
Phys Imaging Radiat Oncol
July 2022
Background/purpose: Tomotherapy may deliver high-quality whole breast irradiation at static angles. The aim of this study was to implement Knowledge-Based (KB) automatic planning for left-sided whole breast using this modality.
Materials/methods: Virtual volumetric plans were associated to the dose distributions of 69 Tomotherapy (TT) clinical plans of previously treated patients, aiming to train a KB-model using a commercial tool completely implemented in our treatment planning system.
Aim: To report toxicity of hypofractionated whole-breast radiotherapy in a large cohort of early-stage breast cancer (BCaients.
Materials And Methods: From 02/2009-05/2017, 1325 consecutive BCa patients were treated with 40.05 Gy/15 fractions, without boost.
Purpose: To implement Knowledge Based (KB) automatic planning for right and left-sided whole breast treatment through a new volumetric technique (ViTAT, Virtual Tangential-fields Arc Therapy) mimicking conventional tangential fields (TF) irradiation.
Materials And Method: A total of 193 clinical plans delivering TF with wedged or field-in-field beams were selected to train two KB-models for right(R) and left(L) sided breast cancer patients using the RapidPlan (RP) tool implemented in the Varian Eclipse system. Then, a template for ViTAT optimization, incorporating individual KB-optimized constraints, was interactively fine-tuned.
Purpose: To train and validate a predictive model of mortality for hospitalized COVID-19 patients based on lung densitometry.
Methods: Two-hundred-fifty-one patients with respiratory symptoms underwent CT few days after hospitalization. "Aerated" (AV), "consolidated" (CV) and "intermediate" (IV) lung sub-volumes were quantified by an operator-independent method based on individual HU maximum gradient recognition.
Aim: We report molecular subtype impact on 1325 early breast cancer (BCa) patients treated with whole breast hypofractionated (WBH) adjuvant forward-planned intensity modulated radiotherapy (F-IMRT) without boost.
Methods And Materials: From 02/2009-05/2017 1325 patients with pTis-pT3, pNx-N1aM0 BCa who underwent breast conservation surgery were treated with WBHF-IMRT in our institute, to a total dose of 40 Gy/15 fractions, without boost. Median age: 62 (interquartile range-IQR-:51.
Purpose: To test the performances of a volumetric arc technique named ViTAT (Virtual Tangential-fields Arc Therapy) mimicking tangential field irradiation for whole breast radiotherapy.
Methods: ViTAT plans consisted in 4 arcs whose starting/ending position were established based on gantry angle distribution of clinical plans for right and left-breast. The arcs were completely blocked excluding the first and last 20°.
Purpose: To report on the implementation, validation and results of the first two proton therapy PBS treatments of limited amplitudes moving targets performed at our center.
Methods And Materials: A real time optical tracking system was used to monitor the patient surface during the CT scan and treatment. This system is also able to trigger the beam during the treatment.