In this study, a miniaturized liquid-liquid extraction (LLE) method for pre-concentration of Na, K, Ca, and Mg in crude oil was proposed. Analytes in crude oil were quantitatively extracted to the aqueous phase, followed by flame atomic absorption spectrometry (FAAS) determination. The following parameters were evaluated: type of extraction solution, sample mass, heating temperature and time, stirring time, centrifugation time, and the use of toluene and chemical demulsifier.
View Article and Find Full Text PDFUrban dust is a mixture of deposited particles from different sources usually linked to potentially toxic elements (PTEs). Despite the industrialization of many South American countries, little is known about the impact of particulate matter in large cities; these data are necessary to promote environmental policies aiming to protect human health. The main objective of this work was to evaluate the particle size distribution, composition, and environmental and human health risks of settled dust particles from Barranquilla, a Colombian Caribbean industrialized area.
View Article and Find Full Text PDFDirect analysis of flour was proposed for the determination of Cl and S by an elemental analyzer for the first time. The main operational conditions of the direct solid sampling elemental analysis (DSS-EA) were optimized and calibrated by standard solutions, rather than by certified reference material (CRM). Accuracy was evaluated by the analysis of CRM of rice flour and by comparison with analyte determination by independent techniques, i.
View Article and Find Full Text PDFThis study proposes the use of an ultrasound-assisted adsorption system coupled to porous ceramic fragments to improve the removal of iron from FeSO aqueous solution. Ultrasound was applied using an ultrasound bath at a low frequency (37 kHz, 330 W). The optimized conditions for Fe removal were achieved by 7 g of adsorbent, 40 min of sonication, 20 mg L of initial Fe concentration, and 30 °C of reaction temperature.
View Article and Find Full Text PDFThe halogen determination is important in view of their biological and environmental roles, but their determination has still been considered a challenge, especially at low concentrations. Therefore, a method for honey decomposition using microwave-induced combustion (MIC) combined with ion chromatography and conductimetric detection (for Cl, F, and S determination) or mass detection (for Br and I determination) (IC-CD-MS) is proposed. Trueness was evaluated by adding reference materials (RMs) or a standard solution in the sample.
View Article and Find Full Text PDFRationale: In this review, works published in the past 25 years for fluorine, chlorine, bromine, and iodine determination in several matrices by inductively coupled plasma mass spectrometry (ICP-MS) were covered. Usually, the determination of halogens has been performed by ICP-MS using a previous sample preparation step or, more recently, by direct analysis of solid or liquid samples.
Methods: Methods based on combustion, extraction, pyrohydrolysis, sample dilution in organic or aqueous medium, and wet digestion, among others, are discussed.
In this work a method based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME) as sample preparation for the extraction and preconcentration of Na, K, Ca and Mg in biodiesel samples was developed. The analytes determination was performed by flame atomic absorption spectrometry (FAAS), operating in emission mode for Na and K and in absorption mode for Ca and Mg. The extraction/preconcentration step of the analytes was performed by using a mixture of dispersant and extractant solvents (isopropanol and HNO, respectively) and the aqueous phase containing the analytes was separated by centrifugation.
View Article and Find Full Text PDFA new strategy based on successive digestions by microwave-induced combustion (MIC) in the same reaction vessel with a single absorbing solution was proposed. As a proof of concept, F was determined by ion-selective electrode (ISE) in seafood digests. Samples were pressed as pellets (up to 0.
View Article and Find Full Text PDFMancozeb (MZ), a manganese- and zinc-containing ethylene-bis-dithiocarbamate, is a broad-spectrum fungicide. Harmful effects of this fungicide have been reported in nontarget organisms via a not fully understood mechanism. has provided remarkable contributions for toxicological studies.
View Article and Find Full Text PDFProg Neuropsychopharmacol Biol Psychiatry
July 2018
Diabetes mellitus (DM) is a chronic metabolic disease that may comorbid with various psychiatric disorders, such as anxiety and depression. The search for effective therapeutics to alleviate hyperglycemia and complications resulting from DM is continuous. Here we investigate the effects of diphenyl diselenide (DD), an organoselenium compound with several pharmacological properties, in a zebrafish model of hyperglycemia.
View Article and Find Full Text PDFA microwave-induced combustion (MIC) system based on the volatilization process was applied for subsequent halogen determination from noncombustible inorganic matrices. Portland cement samples were selected to demonstrate the feasibility of the proposed method, allowing the subsequent determination of Cl and F by ion chromatography (IC). Samples were mixed with high-purity microcrystalline cellulose, wrapped with a polyethylene film and combusted in quartz closed vessels pressurized with oxygen (20bar).
View Article and Find Full Text PDFA method for the simultaneous determination of Ni, V and S in petroleum coke by inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted ultraviolet digestion (MW-UV) in closed vessels was proposed. Digestion was performed using electrodeless discharge lamps positioned inside quartz vessels and turned on by microwave radiation. The following parameters were evaluated: HNO3 concentration (15 mL of 1, 4, 7, 10 or 14.
View Article and Find Full Text PDFThis work demonstrates the feasibility of ultra-trace determination of halogens in biological samples by inductively coupled plasma mass spectrometry (ICP-MS) after decomposition by microwave-induced combustion (MIC). The conventional MIC method was improved to allow the combustion of samples with mass higher than that used in previous works in order to achieve better limits of detection (LODs). The applicability of the proposed method for ultra-trace determination of bromine and iodine in organic samples was demonstrated here using honey.
View Article and Find Full Text PDFThe bromine and iodine content of whey protein concentrate (WPC), hydrolysate (WPH), and isolate (WPI) was evaluated combining microwave-induced combustion (MIC) digestion with inductively coupled plasma mass spectrometry (ICP-MS) determination. MIC digestion allowed the decomposition of up to 500 mg of samples using diluted NH4OH solution (25 mmol L(-1)) for absorption of analytes, assuring the compatibility with ICP-MS determination. Accuracy was evaluated using milk powder certified reference material (NIST 8435) with good agreements for Br and I (102% and 105%, respectively).
View Article and Find Full Text PDFThis work reports the development of a method for Fe extraction in white and red wines using dispersive liquid-liquid microextraction (DLLME) and determination by ultraviolet-visible spectrophotometry. For optimization of the DLLME method, the following parameters were evaluated: type and volume of dispersive (1300 μL of acetonitrile) and extraction (80 μL of C(2)Cl(4)) solvents, pH (3.0), concentration of ammonium pyrrolidinedithiocarbamate (APDC, 500 μL of 1% m/v APDC solution), NaCl concentration (not added), and extraction time.
View Article and Find Full Text PDFEmbryonic animals are especially susceptible to metal exposure. Manganese (Mn) is an essential element, but in excess it can induce toxicity. In this study we used Drosophila melanogaster as an embryonic model to investigate biochemical and behavioral alterations due to Mn exposure.
View Article and Find Full Text PDFA method for heavy and extraheavy crude oil digestion based on microwave-assisted wet digestion (MW-AD) and ultraviolet (UV) radiation using diluted HNO3 was applied for the determination of rare earth elements (REE) by inductively coupled plasma mass spectrometry (ICPMS) with an ultrasonic nebulizer (USN). Even using pressurized systems conventional acid digestion is not feasible for efficient crude oil digestion, especially for heavy and extraheavy crude oils that generally present high amounts of asphaltenes and resins. In the proposed system, UV radiation is generated in situ by immersed electrodeless Cd discharge lamps positioned inside quartz vessels.
View Article and Find Full Text PDFA method for simultaneous determination of clavulanic acid (CA) and amoxicillin (AMO) in commercial tablets was developed using diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and multivariate calibration. Twenty-five samples (10 commercial and 15 synthetic) were used as a calibration set and 15 samples (10 commercial and 5 synthetic) were used for a prediction set. Calibration models were developed using partial least squares (PLS), interval PLS (iPLS), and synergy interval PLS (siPLS) algorithms.
View Article and Find Full Text PDFThe heavy metal mercury is a known toxin, but while the mechanisms involved in mercury toxicity have been well demonstrated in vertebrates, little is known about toxicological effects of this metal in invertebrates. Here, we present the results of our study investigating the effects associated with exposure of fruit fly Drosophila melanogaster to inorganic mercury (HgCl2 ). We quantify survival and locomotor performance as well as a variety of biochemical parameters including antioxidant status, MAPK phosphorylation and gene expression following mercury treatment.
View Article and Find Full Text PDFTotal sulfur concentration was determined in atmospheric residue (AR) and vacuum residue (VR) samples obtained from petroleum distillation process by Fourier transform infrared spectroscopy with attenuated total reflectance (FT-IR/ATR) in association with chemometric methods. Calibration and prediction set consisted of 40 and 20 samples, respectively. Calibration models were developed using two variable selection models: interval partial least squares (iPLS) and synergy interval partial least squares (siPLS).
View Article and Find Full Text PDF