Publications by authors named "Pichl W"

Purpose: The purpose of this study was to evaluate in a sheep model the biomechanical performance of augmented and nonaugmented primary repair of the anterior cruciate ligament (ACL) following transection at the femoral end during a 12-month postoperative observation.

Methods: Forty sheep were randomly assigned to nonaugmented or augmented primary ACL repair using a polyethylene terephthalate (PET) band. At two, six, 16, 26 and 52 weeks postoperatively four sheep in each group were sacrificed and biomechanical testing performed.

View Article and Find Full Text PDF

Osteoporotic fractures are caused by both cortical thinning and trabecular bone loss. Both are seen to be important for bone fragility. The relative contributions of cortical versus trabecular bone have not been established.

View Article and Find Full Text PDF

We retrospectively analyzed 1334 patients who were implanted standard gamma interlocking nails (SGN) to stabilize trochanteric femoral fractures over the years 1992-1998. Reoperation to remove the nails was performed in 37 patients, in 9 of them purely because of pain. Three out of these 9 patients with removed SGN suffered femoral neck fractures in the early postoperative course after having been mobilized to full weight-bearing capacity.

View Article and Find Full Text PDF

Interference screws have become the standard method for fixing bone-patellar tendon-bone (BPTB) grafts. To avoid the inherent pitfalls and complications of interference screws, a 28-mm long and from 5 to 7 mm spreadable metal bolt with nontapping threads was developed for this study. The technical applicability and biomechanical characteristics of this new BPTB interference fixation device were investigated by dissection or tensile testing of 48 cadaveric knee specimens from young donors.

View Article and Find Full Text PDF

OBJECTIVE: To quantify the stress on a reinserted anterior cruciate ligament (ACL) we studied the load sharing between the ACL and a 3.7 mm polyethylene terephthalate (PET) band in 10 knees of fresh human cadavers. DESIGN: The load sharing between the Marshall sutures-ACL complex and the PET band and between the ACL and the PET band was calculated by means of a mathematical model.

View Article and Find Full Text PDF

The rupture of the anterior cruciate ligament (ACL) near its femoral origin is a common injury of the knee and can lead to lesions of the meniscus due to instability and to early gonarthrosis. One procedure applied in current orthopaedic practice to prevent such impairment of knee joint function is ACL repair reinforced with a synthetic intraarticular ligament. In this study we used twelve knees of cadavers and after sectioning the ACL in each repaired it according the Marshall technique with USP 1 PDS II sutures.

View Article and Find Full Text PDF