Publications by authors named "Phinney K"

Background: Urine albumin (UA) is an important biomarker of chronic kidney disease. Current in vitro diagnostic medical devices (IVD-MDs) for measuring UA are not standardized, and median results among IVD-MDs differ by approximately 45%. Since fixed decision values are used to interpret UA, higher-order reference measurement procedures (RMPs) are needed for metrological traceability.

View Article and Find Full Text PDF

Lipid nanoparticle-encapsulated mRNA (LNP-mRNA) holds great promise as a novel modality for treating a broad range of diseases. The ability to quantify mRNA accurately in therapeutic products helps to ensure consistency and safety. Here, we consider a central aspect of accuracy, measurement traceability, which establishes trueness in quantity.

View Article and Find Full Text PDF

The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels.

View Article and Find Full Text PDF

Objectives: Vitamin D-binding protein (VDBP), a serum transport protein for 25-hydroxyvitamin D [25(OH)D], has three common proteoforms which have co-localized amino acid variations and glycosylation. A monoclonal immunoassay was found to differentially detect VDBP proteoforms and methods using liquid chromatography-tandem mass spectrometry (LC-MS/MS) might be able to overcome this limitation. Previously developed multiple reaction monitoring LC-MS/MS methods for total VDBP quantification represent an opportunity to probe the potential effects of proteoforms on proteolysis, instrument response and quantification accuracy.

View Article and Find Full Text PDF

Biopharmaceuticals such as monoclonal antibodies are required to be rigorously characterized using a wide range of analytical methods. Various material properties must be characterized and well controlled to assure that clinically relevant features and critical quality attributes are maintained. A thorough understanding of analytical method performance metrics, particularly emerging methods designed to address measurement gaps, is required to assure methods are appropriate for their intended use in assuring drug safety, stability, and functional activity.

View Article and Find Full Text PDF

Vitamin D, an important hormone with a central role in calcium and phosphate homeostasis, is required for bone and muscle development as well as preservation of musculoskeletal function. The most abundant vitamin D metabolite is 25-hydroxyvitamin D [25(OH)D], which is currently considered the best marker to evaluate overall vitamin D status. 25(OH)D is therefore the most commonly measured metabolite in clinical practice.

View Article and Find Full Text PDF

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes serum samples globally, on a quarterly basis, to assess participants' performance of specific methods for 25-hydroxyvitamin D (25OHD) and 1,25-dihydroxyvitamin D (1,25-(OH)D). DEQAS occasionally circulates samples containing high levels of substances found in certain clinical situations e.g.

View Article and Find Full Text PDF

Vitamin D plays a vital role in successful pregnancy outcomes for both the mother and fetus. Vitamin D is bound to vitamin D binding protein (VDBP) in blood and is carried to the liver, kidneys and other target tissues. Accurate measurements of the clinically measured metabolite of vitamin D, 25-hydroxyvitamin D [25(OH)D], depend on complete removal from the binding protein.

View Article and Find Full Text PDF

Accurate, traceable quantification of ribonucleotide or deoxyribonucleotide oligomers is achievable using acid hydrolysis and isotope dilution mass spectrometry (ID-MS). In this work, formic acid hydrolysis is demonstrated to generate stoichiometric release of nucleobases from intact oligonucleotides, which then can be measured by ID-MS, facilitating true and precise absolute quantification of RNA, short linearized DNA, or genomic DNA. Surrogate nucleobases are quantified with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) workflow, using multiple reaction monitoring (MRM).

View Article and Find Full Text PDF

The discovery that mutations of the CYP24A1 gene are a cause of idiopathic infantile hypercalcemia (IIH) has revived interest in measuring serum 24,25(OH)D. Several studies have also suggested that a high 25-hydroxyvitamin D(25-OHD):24,25(OH)D ratio might provide additional diagnostic information in the investigation of vitamin D deficiency. Measurement of 24,25(OH)D is necessarily restricted to laboratories with mass spectrometry methods although cross reactivity of the metabolite in immunoassays for 25-OHD is a potential cause of misleading results.

View Article and Find Full Text PDF

Quantification of cardiac troponin I (cTnI), a protein biomarker used for diagnosing myocardial infarction, has been achieved in native patient plasma based on an immunoaffinity enrichment strategy and isotope dilution (ID) liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. The key steps in the workflow involved isolating cTnI from plasma using anti-cTnI antibody coupled to magnetic nanoparticles, followed by an enzymatic digestion with trypsin. Three tryptic peptides from cTnI were monitored and used for quantification by ID-LC-MS/MS via multiple reaction monitoring (MRM).

View Article and Find Full Text PDF

The NISTmAb Reference Material (RM) 8671 is intended to be an industry standard monoclonal antibody for pre-competitive harmonization of best practices and designing next generation characterization technologies for identity, quality, and stability testing. It must therefore embody the quality and characteristics of a typical biopharmaceutical product and be available long-term in a stable format with consistent product quality attributes. A stratified sampling and analysis plan using a series of qualified analytical and biophysical methods is described that assures RM 8671 meets these criteria.

View Article and Find Full Text PDF

Vitamin-D-binding protein (VDBP), a transporter of 25-hydroxyvitamin D metabolites, has three common isoforms. The relationship of the isoforms and their glycosylation state with various diseases has been under recent examination. In this work, liquid chromatography coupled to isotope dilution mass spectrometry was evaluated for quantification of VDBP, the three common isoforms, and total glycosylation.

View Article and Find Full Text PDF

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements and the Vitamin D Standardization Program, has recently issued a new serum-matrix Standard Reference Material (SRM): 2973 Vitamin D Metabolites in Frozen Human Serum (High Level). SRM 2973 was designed to provide a serum material with a total 25-hydroxyvitamin D [25(OH)D] concentration near 100 nmol/L to complement the existing serum-based SRMs with values assigned for total 25(OH)D between 20 and 80 nmol/L. Values were assigned for 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25(OH)D3, and total 25(OH)D [the sum of 25(OH)D2 + 25(OH)D3] using the NIST isotope dilution LC with tandem MS (MS/MS) reference measurement procedure (RMP) and related methods.

View Article and Find Full Text PDF
Article Synopsis
  • Since 2005, NIST has worked with NIH's Office of Dietary Supplements to enhance the measurement quality of vitamin D nutritional markers.
  • Their efforts have included creating validated methods, standard Reference Materials (SRMs), and quality assurance programs for lab measurements.
  • Key achievements include developing reference procedures for various vitamin D forms, assigning values to study samples, and establishing the first accuracy-based QA program for vitamin D measurement in human serum/plasma.
View Article and Find Full Text PDF

The Vitamin D Standardization Program (VDSP) coordinated an interlaboratory study to assess the comparability of measurements of total 25-hydroxyvitamin D [25(OH)D] in human serum, which is the primary marker of vitamin D status. A set of 50 individual donor samples were analyzed by 15 different laboratories representing national nutrition surveys, assay manufacturers, and clinical and/or research laboratories to provide results for total 25(OH)D using both immunoassays (IAs) and LC tandem MS (MS/MS). The results were evaluated relative to bias compared with the target values assigned based on a combination of measurements at Ghent University (Belgium) and the U.

View Article and Find Full Text PDF

The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme.

View Article and Find Full Text PDF
Article Synopsis
  • The Vitamin D Standardization Program (VDSP) has created tools to help labs standardize tests for 25-hydroxyvitamin D, ensuring accuracy in laboratory results.
  • The paper outlines specific steps for labs to follow, including initial calibration and assessment of accuracy, which can apply to both commercial and in-house testing methods.
  • Labs are encouraged to maintain a total coefficient of variation (CV) of ≤10% and a mean bias of ≤5%, with guidance provided for achieving these goals using various approaches.
View Article and Find Full Text PDF

Assay variability has been cited as an obstacle to establishing optimal vitamin D exposure. As part of the Vitamin D Standardization Program (VDSP) effort to standardize the measurement of total 25-hydroxyvitamin D [25(OH)D], the value assignment of total 25(OH)D in 50 single-donor serum samples was performed using two isotope-dilution LC with tandem MS methods. Both methods are recognized as reference measurement procedures (RMPs) by the Joint Committee for Traceability in Laboratory Medicine.

View Article and Find Full Text PDF

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum.

View Article and Find Full Text PDF

The Vitamin D External Quality Assessment Scheme (DEQAS) was launched in 1989 and monitors the performance of 25-hydroxyvitamin D (25-OHD) and 1,25- dihydroxyvitamin D (1,25(OH)D) assays. In April 2015 a pilot scheme for 24,25-dihydroxyvitamin D (24,25(OH)D) was introduced. The 25-OHD scheme is accuracy - based with target values assigned by the NIST Reference Measurement Procedure (RMP) for 25-OHD and 25-OHD.

View Article and Find Full Text PDF

Using mAbs as therapeutic molecules is complicated by the propensity of mAbs to aggregate at elevated concentrations, which can lead to a variety of adverse events in treatment. Here, we describe a proof-of-concept for new methodology to detect and quantify mAb aggregation. Assay development included using an aggregated mAb as bait for screening of phage display peptide library and identifying those peptides with random sequence which can recognize mAb aggregates.

View Article and Find Full Text PDF

A method to discover and correct errors in mass spectral libraries is described. Comparing across a set of highly curated reference libraries compounds that have the same chemical structure quickly identifies entries that are outliers. In cases where three or more entries for the same compound are compared, the outlier as determined by visual inspection was almost always found to contain the error.

View Article and Find Full Text PDF

Quantifying the amount of antibody on magnetic particles is a fundamental, but often overlooked step in the development of magnetic separation-based immunoaffinity enrichment procedures. In this work, a targeted mass spectrometry (MS)-based method was developed to directly measure the amount of antibody covalently bound to magnetic particles. Isotope-dilution liquid chromatography-tandem MS (ID-LC-MS/MS) has been extensively employed as a gold-standard method for protein quantification.

View Article and Find Full Text PDF

N-glycosylation of proteins is well known to occur at asparagine residues that fall within the canonical consensus sequence N-X-S/T but has also been identified at a small number of asparagine residues within N-X-C motifs, including the N491 residue of human serotransferrin. Here we report novel glycosylation sites within noncanonical consensus motifs, in the conformation N-X-C, based on mass spectrometry analysis of partially deglycosylated glycopeptide targets. Alpha-1-acid glycoprotein (A1AG) and serotransferrin (Tf) were observed for the first time to be N-glycosylated on asparagine residues within a total of six unique noncanonical motifs.

View Article and Find Full Text PDF