Publications by authors named "Phillip Wall"

Background: Quality assurance (QA) remains unstandardized for CT-guided online adaptive radiotherapy (CTgART) platforms (Ethos, Varian Medical Systems, Inc., Palo Alto, CA), as they become more clinically prevalent. A secondary dose calculation software (Mobius3D, Varian Medical Systems, Inc.

View Article and Find Full Text PDF

Purpose: Performing measurement-based patient-specific quality assurance (PSQA) is recognized as a resource-intensive and time inefficient task in the radiation therapy treatment workflow. Paired with technological refinements in modern radiation therapy, research toward measurement-free PSQA has seen increased interest during the past 5 years. However, these efforts have not been clinically implemented or prospectively validated in the United States.

View Article and Find Full Text PDF

Background: To evaluate acute and late genitourinary and gastrointestinal toxicities and patient reported urinary and sexual function following accelerated, hypofractionated external beam radiotherapy to the prostate, seminal vesicles and pelvic lymph nodes and high dose rate (HDR) brachytherapy or stereotactic body radiation therapy (SBRT) prostate boost.

Methods: Patients at a single institution with NCCN intermediate- and high-risk localized prostate cancer with logistical barriers to completing five weeks of whole pelvic radiotherapy (WPRT) were retrospectively reviewed for toxicity following accelerated, hypofractionated WPRT (41.25 Gy in 15 fractions of 2.

View Article and Find Full Text PDF

Background: Strategies for managing respiratory motion, specifically motion-encompassing methods, in radiation therapy typically assume reproducible breathing. In reality, respiratory motion variations occur and ultimately cause tumor motion variations, which can result in differences between the planned and delivered dose distributions. Therefore, breathing guidance techniques have been investigated to improve respiratory reproducibility.

View Article and Find Full Text PDF

Introduction: Previous literature has shown general trade-offs between plan complexity and resulting quality assurance (QA) outcomes. However, existing solutions for controlling this trade-off do not guarantee corresponding improvements in deliverability. Therefore, this work explored the feasibility of an optimization framework for directly maximizing predicted QA outcomes of plans without compromising the dosimetric quality of plans designed with an established knowledge-based planning (KBP) technique.

View Article and Find Full Text PDF

Purpose: Knowledge-based planning (KBP) techniques have been reported to improve plan quality, efficiency, and consistency in radiation therapy. However, plan complexity and deliverability have not been addressed previously for treatment plans guided by an established in-house KBP system. The purpose of this work was to assess dosimetric, mechanical, and delivery properties of plans designed with a common KBP method for prostate cases treated via volumetric modulated arc therapy (VMAT).

View Article and Find Full Text PDF

Purpose: This article investigates dose-volume prediction improvements in a common knowledge-based planning (KBP) method using a Pareto plan database compared with using a conventional, clinical plan database.

Methods And Materials: Two plan databases were created using retrospective, anonymized data of 124 volumetric modulated arc therapy (VMAT) prostate cancer patients. The clinical plan database (CPD) contained planning data from each patient's clinically treated VMAT plan, which were manually optimized by various planners.

View Article and Find Full Text PDF

The overlap volume histogram (OVH) is an anatomical metric commonly used to quantify the geometric relationship between an organ at risk (OAR) and target volume when predicting expected dose-volumes in knowledge-based planning (KBP). This work investigated the influence of additional variables contributing to variations in the assumed linear DVH-OVH correlation for the bladder and rectum in VMAT plans of prostate patients, with the goal of increasing prediction accuracy and achievability of knowledge-based planning methods. VMAT plans were retrospectively generated for 124 prostate patients using multi-criteria optimization.

View Article and Find Full Text PDF

Background: MicroRNAs (miRNAs) are small RNAs (sRNA) approximately 21 nucleotides in length that negatively control gene expression by cleaving or inhibiting the translation of target gene transcripts. miRNAs have been extensively analyzed in Arabidopsis and rice and partially investigated in other non-model plant species. To date, 109 and 62 miRNA families have been identified in Arabidopsis and rice respectively.

View Article and Find Full Text PDF

In order to facilitate behavioral, and potentially pharmacological, analyses of risk assessment behaviors in mice, a rat exposure test (RET) was devised and evaluated. This test provides a home chamber connected via a tunnel to a rat (predator) exposure area. Familiar substrate is provided to permit burying, and mouse subjects are habituated to the apparatus prior to exposure to an amphetamine-activated rat.

View Article and Find Full Text PDF

Mobile luminal thrombus of the descending thoracic aorta is an unusual finding in patients with peripheral embolization. The diagnosis is best made with transesophageal echography (TEE). Traditionally, systemic anticoagulation and selective surgical thrombectomy are standard treatment.

View Article and Find Full Text PDF