Publications by authors named "Philippe Hubert"

A transmission detection mode was investigated with SERS analyses (SETRS). A comparison between backscattering and transmission detection modes was conducted to demonstrate the feasibility of performing SETRS analyses. The impact of various parameters on the SERS signal intensity such as sample volume, lens collection optic, laser beam size and laser power were then examined.

View Article and Find Full Text PDF

A major limitation preventing the use of surface-enhanced Raman scattering (SERS) in routine analyses is the signal variability due to the heterogeneity of metallic nanoparticles used as SERS substrates. This study aimed to robustly optimise a synthesis process of silver nanoparticles to improve the measured SERS signal repeatability and the protocol synthesis repeatability. The process is inspired by a chemical reduction method associated with microwave irradiation to guarantee better controlled and uniform heating.

View Article and Find Full Text PDF

The process of developing new reversed-phase liquid chromatography methods can be both time-consuming and challenging. To meet this challenge, statistics-based strategies have emerged as cost-effective, efficient and flexible solutions. In the present study, we use a Bayesian response surface methodology, which takes advantage of the knowledge of the pKa values of the compounds present in the analyzed sample to model their retention behavior.

View Article and Find Full Text PDF

The 4th Annual Forum on Endocrine Disrupters organized by the European Commission brought together the authors of this article around the topic: “From bench to validated test guidelines: (pre)val­idation of test methods”. Validation activities are meant to demonstrate the relevance and reliability of methods and approaches used in regulatory safety testing. These activities are essential to facil­itate regulatory use, still they are largely underfunded and unattractive to the scientific community.

View Article and Find Full Text PDF

Vitamin D, an essential micronutrient, often requires supplementation via medicines or food supplements, which necessitate quality control (QC). This study presents the development of a method for detecting and quantifying seven impurities of vitamin D in oily drug products using supercritical fluid chromatography-mass spectrometry (SFC-MS). Targeted impurities include two esters of vitamin D and five non-esters including four that are isobaric to vitamin D.

View Article and Find Full Text PDF

In addition to its potent antiplatelet activity, ticagrelor possesses antibacterial properties against gram-positive bacteria. We wondered whether the typical clinical dosage of ticagrelor could prevent the development of infective endocarditis caused by highly virulent . Ticagrelor prevented vegetation formation in a mouse model of inflammation-induced endocarditis.

View Article and Find Full Text PDF

Near-infrared (NIR) spectroscopy is actually a well-established technique that demonstrates its performance in the frame of detection of poor-quality medicines. The use of low-cost handheld NIR spectrophotometers in low-resource contexts can allow an inexpensive and more rapid detection compared to laboratory methods. Considering these points, it was decided to develop, validate, and transfer methods for the quantification of ciprofloxacin and metronidazole tablet samples using a NIR handheld spectrophotometer in transmission mode (NIR-M-T1) coupled to chemometrics such as partial least squares regression (PLSR) algorithm.

View Article and Find Full Text PDF

The negative consequences of Substandard and falsified (SF) medicines are widely documented nowadays and there is still an urgent need to find them in more efficient ways. Several screening tools have been developed for this purpose recently. In this study, three screening tools were used on 292 samples of ciprofloxacin and metronidazole collected in Cameroon.

View Article and Find Full Text PDF

Surface-enhanced Raman scattering (SERS) is a vibrational widely used technique thanks to its multiple advantages such as its high specificity and sensitivity. The Raman signal exaltation comes from the use of metallic nanoparticles (Nps) acting as antennas by amplifying the Raman scattering. Controlling the Nps synthesis is a major point for the implementation of SERS in routine analysis and especially in quantitative applications.

View Article and Find Full Text PDF

Growing evidence shows that endocrine disruptors (EDs), known to affect the reproductive system, may also disturb other hormone-regulated functions leading to cancers, neurodevelopmental defects, metabolic and immune diseases. To reduce exposure to EDs and limit their health effects, development of screening and mechanism-based assays to identify EDs is encouraged. Nevertheless, the crucial validation step of test methods by regulatory bodies is a time- and resource-consuming process.

View Article and Find Full Text PDF

Reversed-Phase Liquid Chromatography (RPLC) is a common liquid chromatographic mode used for the control of pharmaceutical compounds during their drug life cycle. Nevertheless, determining the optimal chromatographic conditions that enable this separation is time consuming and requires a lot of lab work. Quantitative Structure Retention Relationship models (QSRR) are helpful for doing this job with minimal time and cost expenditures by predicting retention times of known compounds without performing experiments.

View Article and Find Full Text PDF

Quality is one of the essential components of medicines and needs to be ensured to preserve the population's health. This can be achieved through post-marketing quality control of medicines and is one of the most important duties of national regulatory authorities. In collaboration with the Cameroonian National Drug Quality Control and Valuation Laboratory, the decision was made to initiate a prevalence study to assess the quality of antiinfective medicines in Cameroon.

View Article and Find Full Text PDF

In the pharmaceutical field, and more precisely in quality control laboratories, robust liquid chromatographic methods are needed to separate and analyze mixtures of compounds. The development of such chromatographic methods for new mixtures can result in a long and tedious process even while using the design of experiments methodology. However, developments could be accelerated with the help of in silico screening.

View Article and Find Full Text PDF

Purpose: Discovery of falsified Symbicort 320/9 Turbohaler identified in the UK in 2013 demonstrated that falsified dry powder inhalers were also present in the European market. This work aimed to investigate the current situation of formoterol-containing dry powder inhalers in Europe and North Africa by assessing their aerodynamic performance profile.

Methods: A total of eight registered formoterol-based dry powder inhalers over the European and North African markets were involved in this study, including the reference drug Foradil.

View Article and Find Full Text PDF

Quality control is a fundamental and critical activity in the pharmaceutical industry that guarantees the quality of medicines. QC analyses are currently performed using several well-known techniques, mainly liquid and gas chromatography. However, current trends are focused on the development of new techniques to reduce analysis time and cost, to improve the performances and decrease ecological footprint.

View Article and Find Full Text PDF

The ultimate goal of a one-class classifier like the "rigorous" soft independent modeling of class analogy (SIMCA) is to predict with a certain confidence probability, the conformity of future objects with a given reference class. However, the SIMCA model, as currently implemented often suffers from an undercoverage problem, meaning that its observed sensitivity often falls far below the desired theoretical confidence probability, hence undermining its intended use as a predictive tool. To overcome the issue, the most reported strategy in the literature, involves incrementing the nominal confidence probability until the desired sensitivity is obtained in cross-validation.

View Article and Find Full Text PDF

Vibrational spectroscopic techniques, i.e., attenuated total reflectance infrared (ATR-IR), near infrared spectroscopy (NIRS) and Raman spectroscopy (RS), coupled with Partial Least Squares Regression (PLSR), were evaluated as cost-effective label-free and reagent-free tools to monitor water content in Levulinic Acid/L-Proline (LALP) (2:1, mol/mol) Natural Deep Eutectic Solvent (NADES).

View Article and Find Full Text PDF

Glycosylation is considered a critical quality attribute of therapeutic proteins as it affects their stability, bioactivity, and safety. Hence, the development of analytical methods able to characterize the composition and structure of glycoproteins is crucial. Existing methods are time consuming, expensive, and require significant sample preparation, which can alter the robustness of the analyses.

View Article and Find Full Text PDF

Glyphosate, also known as N-(phosphonomethyl)glycine, is one of the most widely used herbicides in the world. However, the controversy surrounding the toxicity of glyphosate and its main breakdown product, aminomethylphosphonic acid (AMPA), remains a serious public concern. Therefore, there is a clear need to develop a rapid, sensitive and automated alternative method for the quantification of glyphosate and AMPA.

View Article and Find Full Text PDF

Cannabis has been at the center of scientific attention for some years now. Since its pharmacological potential has been highlighted, cannabis has become a hot topic in research laboratories, leading to the publication of many scientific studies. Focusing on analytical chemistry, an enormous number of analytical methods for cannabinoid (CNB) determination have been published, involving various techniques.

View Article and Find Full Text PDF

There is a rising interest in the modeling and predicting of chromatographic retention. The progress towards more complex and comprehensive models emphasized the need for broad reliable datasets. The present dataset comprises small pharmaceutical compounds selected to cover a wide range in terms of physicochemical properties that are known to impact the retention in reversed-phase liquid chromatography.

View Article and Find Full Text PDF

Previously, we introduced a novel one-class classification (OCC) concept for spectra. It uses as acceptance space for genuine spectra of the target chemical, a prediction band in the wavelengths' space. As a decision rule, test spectra falling substantially outside this band are rejected as noncomplying with the target, and their deviations are documented in the wavelengths' space.

View Article and Find Full Text PDF

Multivariate curve resolution unmixing of hyperspectral imaging data can be challenging when low sources of variance are present in complex samples, as for minor (low-concentrated) chemical compounds in pharmaceutical formulations. In this work, it was shown how the reduction of hyperspectral imaging data matrices through the selection of essential spectra can be crucial for the analysis of complex unknown pharmaceutical formulation applying Multivariate Curve Resolution - Alternating Least Squares (MCR-ALS). Results were obtained on simulated datasets and on real FT-IR and Raman hyperspectral images of both genuine and falsified tablets.

View Article and Find Full Text PDF

Almost 60% of commercialized pharmaceutical proteins are glycosylated. Glycosylation is considered a critical quality attribute, as it affects the stability, bioactivity and safety of proteins. Hence, the development of analytical methods to characterise the composition and structure of glycoproteins is crucial.

View Article and Find Full Text PDF