Background: Low mobility of patients during hospitalisation is associated with adverse outcomes. To successfully change behaviours related to mobility of older hospitalised patients, we need to better understand the mechanisms underlying patient and healthcare professional behaviours. In this study, we thus assessed patient- and healthcare professional-reported intentions and behaviours related to mobility of older patients hospitalised on an acute medical ward, based on a theoretical framework - the Health Action Process Approach (HAPA) model - and on additional barriers and facilitators to mobility.
View Article and Find Full Text PDFThe measurement of the pressure field radiated by a sound source has many applications in the fields of noise control and loudspeaker system design. In this paper, the radiation mode method is used to measure the field radiated by a complex acoustic source whose surface impedance is arbitrary and does not correspond to the Neumann boundary condition used for the calculation of radiation modes. The most effective radiation modes are used as test functions to calculate a pressure expansion around the source under test, an expansion that matches the measured pressure at a limited number of points close to the source.
View Article and Find Full Text PDFBackground: Low mobility during an acute care medical hospitalization is frequent and associated with adverse outcomes, particularly among older patients. Better understanding barriers and facilitators to improve mobility during hospitalization could help develop effective interventions. The goal of this study was to assess barriers and facilitators to older medical patients' hospital mobility, from the point of view of patients and clinicians, to develop a framework applicable in clinical practice.
View Article and Find Full Text PDFIntroduction: Smoking prevalence is twice as high among patients admitted to hospital because of the acute condition of aneurysmal subarachnoid hemorrhage (aSAH) as in the general population. Smoking cessation may improve the prognosis of aSAH, but nicotine replacement therapy (NRT) administered at the time of aSAH remains controversial because of potential adverse effects such as cerebral vasospasm. We investigated the international practice of NRT use for aSAH among neurosurgeons.
View Article and Find Full Text PDFUnlabelled: The performance of cochlear implant (CI) listeners is limited by several factors among which the lack of spatial selectivity of the electrical stimulation. Recently, many studies have explored the use of multipolar strategies where several electrodes are stimulated simultaneously to focus the electrical field in a restricted region of the cochlea.
Objective: These strategies are based on several assumptions concerning the electrical properties of the inner ear that need validation.
Acoustic communication is widespread in animals. According to the sensory drive hypothesis [Endler JA (1993) Philos Trans R Soc Lond B Biol Sci 340(1292):215-225], communication signals and perceptual systems have coevolved. A clear illustration of this is the evolution of the tetrapod middle ear, adapted to life on land.
View Article and Find Full Text PDFThis article presents the experimental implementation and results of a hybrid passive/active absorber (smart foam) made up from the combination of a passive absorbent (foam) and a curved polyvinylidene fluoride (PVDF) film actuator bonded to the rear surface of the foam. Various smart foam prototypes were built and tested in active absorption experiments conducted in an impedance tube under plane wave propagation condition at frequencies between 100 and 1500 Hz. Three control cases were tested.
View Article and Find Full Text PDFSound directivity control is made possible by a compact array of independent loudspeakers operating at the same frequency range. The drivers are usually distributed over a sphere-like frame according to a Platonic solid geometry to obtain a highly symmetrical configuration. The radiation pattern of spherical loudspeaker arrays has been predicted from the surface velocity pattern by approximating the drivers membranes as rigid vibrating spherical caps, although a rigorous assessment of this model has not been provided so far.
View Article and Find Full Text PDFThis paper evaluates the potential of the field separation method (FSM) for performing subwoofer measurements in a small test room with poor absorbing properties, as is commonly available. The FSM requires the knowledge of both acoustic pressure and velocity fields on a closed surface surrounding the tested source. Pressures and velocities, measured using a p-p probe on a half-sphere mesh, are collected under various conditions: in a room with variable reverberation time (6.
View Article and Find Full Text PDFThe "smart foam" concept and design originate from the combination of the passive dissipation capability of foam in the medium and high frequency ranges and the active absorption ability of piezoelectric actuator (generally polyvinylidene fluoride) in the low frequency range. This results into a passive/active absorption control device that can efficiently operate over a broad range of frequencies. In this paper, a full three dimensional finite element model of smart foam is presented including its experimental validation.
View Article and Find Full Text PDFThis study investigated the dimensions underlying perceived differences between loudspeakers. Listeners compared the sound reproduction of 12 loudspeakers in a room, using three musical excerpts. For the loudspeakers to be compared one just after the other in exactly the same conditions, the sounds radiated by the loudspeakers were recorded in a listening room, and the recorded sounds were submitted to paired comparisons using headphones.
View Article and Find Full Text PDFComparison of loudspeakers is a major concern during design or product selection. There are several standards for the measurement of loudspeaker characteristics, but none of them provides hints for a rigorous comparison between devices. In this study, different ways of evaluating acoustical dissimilarity between loudspeakers were compared.
View Article and Find Full Text PDF