Publications by authors named "Philipp Seebock"

Automated lesion detection in retinal optical coherence tomography (OCT) scans has shown promise for several clinical applications, including diagnosis, monitoring and guidance of treatment decisions. However, segmentation models still struggle to achieve the desired results for some complex lesions or datasets that commonly occur in real-world, e.g.

View Article and Find Full Text PDF

Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies.

Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights.

View Article and Find Full Text PDF

Background: International societies have issued guidelines for high-risk breast cancer (BC) screening, recommending contrast-enhanced magnetic resonance imaging (CE-MRI) of the breast as a supplemental diagnostic tool. In our study, we tested the applicability of deep learning-based anomaly detection to identify anomalous changes in negative breast CE-MRI screens associated with future lesion emergence.

Methods: In this prospective study, we trained a generative adversarial network on dynamic CE-MRI of 33 high-risk women who participated in a screening program but did not develop BC.

View Article and Find Full Text PDF

Objectives: To evaluate the quantitative impact of drusen and hyperreflective foci (HRF) volumes on mesopic retinal sensitivity in non-exudative age-related macular degeneration (AMD).

Methods: In a standardized follow-up scheme of every three months, retinal sensitivity of patients with early or intermediate AMD was assessed by microperimetry using a custom pattern of 45 stimuli (Nidek MP-3, Gamagori, Japan). Eyes were consecutively scanned using Spectralis SD-OCT (20° × 20°, 1024 × 97 × 496).

View Article and Find Full Text PDF

Background/aims: Image quality assessment (IQA) is crucial for both reading centres in clinical studies and routine practice, as only adequate quality allows clinicians to correctly identify diseases and treat patients accordingly. Here we aim to develop a neural network for automated real-time IQA in colour fundus (CF) and fluorescein angiography (FA) images.

Methods: Training and evaluation of two neural networks were conducted using 2272 CF and 2492 FA images, with binary labels in four (contrast, focus, illumination, shadow and reflection) and three (contrast, focus, noise) modality specific categories plus an overall quality ranking.

View Article and Find Full Text PDF

Background/objectives: We aim to develop an objective fully automated Artificial intelligence (AI) algorithm for MNV lesion size and leakage area segmentation on fluorescein angiography (FA) in patients with neovascular age-related macular degeneration (nAMD).

Subjects/methods: Two FA image datasets collected form large prospective multicentre trials consisting of 4710 images from 513 patients and 4558 images from 514 patients were used to develop and evaluate a deep learning-based algorithm to detect CNV lesion size and leakage area automatically. Manual segmentation of was performed by certified FA graders of the Vienna Reading Center.

View Article and Find Full Text PDF

In clinical routine, ophthalmologists frequently analyze the shape and size of the foveal avascular zone (FAZ) to detect and monitor retinal diseases. In order to extract those parameters, the contours of the FAZ need to be segmented, which is normally achieved by analyzing the retinal vasculature (RV) around the macula in fluorescein angiograms (FA). Computer-aided segmentation methods based on deep learning (DL) can automate this task.

View Article and Find Full Text PDF

The fovea centralis is an essential landmark in the retina where the photoreceptor layer is entirely composed of cones responsible for sharp, central vision. The localization of this anatomical landmark in optical coherence tomography (OCT) volumes is important for assessing visual function correlates and treatment guidance in macular disease. In this study, the "PRE U-net" is introduced as a novel approach for a fully automated fovea centralis detection, addressing the localization as a pixel-wise regression task.

View Article and Find Full Text PDF

Purpose: To develop and validate a deep learning model to automatically segment three structures using an anterior segment optical coherence tomography (AS-OCT): The intraocular lens (IOL), the retrolental space (IOL to the posterior lens capsule) and Berger's space (BS; posterior capsule to the anterior hyaloid membrane).

Methods: An artificial intelligence (AI) approach based on a deep learning model to automatically segment the IOL, the retrolental space, and BS in AS-OCT, was trained using annotations from an experienced clinician. The training, validation and test set consisted of 92 cross-sectional OCT slices, acquired in 47 visits from 41 eyes.

View Article and Find Full Text PDF

Purpose: The currently used measures of retinal function are limited by being subjective, nonlocalized, or taxing for patients. To address these limitations, we sought to develop and evaluate a deep learning (DL) method to automatically predict the functional end point (retinal sensitivity) based on structural OCT images.

Design: Retrospective, cross-sectional study.

View Article and Find Full Text PDF

Retinal fluid as the major biomarker in exudative macular disease is accurately visualized by high-resolution three-dimensional optical coherence tomography (OCT), which is used world-wide as a diagnostic gold standard largely replacing clinical examination. Artificial intelligence (AI) with its capability to objectively identify, localize and quantify fluid introduces fully automated tools into OCT imaging for personalized disease management. Deep learning performance has already proven superior to human experts, including physicians and certified readers, in terms of accuracy and speed.

View Article and Find Full Text PDF

Aim: To objectively assess disease activity and treatment response in patients with retinal vein occlusion (RVO), neovascular age-related macular degeneration (nAMD) and centre-involved diabetic macular oedema (DME), using artificial intelligence-based fluid quantification.

Methods: Posthoc analysis of 2311 patients (11 151 spectral-domain optical coherence tomography volumes) from five clinical, multicentre trials, who received a flexible antivascular endothelial growth factor (anti-VEGF) therapy over a 12-month period. Fluid volumes were measured with a deep learning algorithm at baseline/months 1, 2, 3 and 12, for three concentric circles with diameters of 1, 3 and 6 mm (fovea, paracentral ring and pericentral ring), as well as four sectors surrounding the fovea (superior, nasal, inferior and temporal).

View Article and Find Full Text PDF

Artificial intelligence has recently made a disruptive impact in medical imaging by successfully automatizing expert-level diagnostic tasks. However, replicating human-made decisions may inherently be biased by the fallible and dogmatic nature of human experts, in addition to requiring prohibitive amounts of training data. In this paper, we introduce an unsupervised deep learning architecture particularly designed for OCT representations for unbiased, purely data-driven biomarker discovery.

View Article and Find Full Text PDF
Article Synopsis
  • The authors acknowledge an error in the published figure of their paper regarding the anatomical segmentation in retinal OCT.
  • They intend to provide an updated version of Fig. 3 to correct the mistake.
  • The correct output of the last convolutional layers should indicate "11" channels instead of "2," accounting for 10 retinal layers plus the background.
View Article and Find Full Text PDF

Diagnosis and treatment in ophthalmology depend on modern retinal imaging by optical coherence tomography (OCT). The recent staggering results of machine learning in medical imaging have inspired the development of automated segmentation methods to identify and quantify pathological features in OCT scans. These models need to be sensitive to image features defining patterns of interest, while remaining robust to differences in imaging protocols.

View Article and Find Full Text PDF

Diagnosis and treatment guidance are aided by detecting relevant biomarkers in medical images. Although supervised deep learning can perform accurate segmentation of pathological areas, it is limited by requiring a priori definitions of these regions, large-scale annotations, and a representative patient cohort in the training set. In contrast, anomaly detection is not limited to specific definitions of pathologies and allows for training on healthy samples without annotation.

View Article and Find Full Text PDF

Obtaining expert labels in clinical imaging is difficult since exhaustive annotation is time-consuming. Furthermore, not all possibly relevant markers may be known and sufficiently well described a priori to even guide annotation. While supervised learning yields good results if expert labeled training data is available, the visual variability, and thus the vocabulary of findings, we can detect and exploit, is limited to the annotated lesions.

View Article and Find Full Text PDF

The identification and quantification of markers in medical images is critical for diagnosis, prognosis, and disease management. Supervised machine learning enables the detection and exploitation of findings that are known a priori after annotation of training examples by experts. However, supervision does not scale well, due to the amount of necessary training examples, and the limitation of the marker vocabulary to known entities.

View Article and Find Full Text PDF