Publications by authors named "Philip L Worthington"

Insulin- and contraction-stimulated increases in glucose uptake into skeletal muscle occur in part as a result of the translocation of glucose transporter 4 (GLUT4) from intracellular stores to the plasma membrane (PM). This study aimed to use immunofluorescence microscopy in human skeletal muscle to quantify GLUT4 redistribution from intracellular stores to the PM in response to glucose feeding and exercise. Percutaneous muscle biopsy samples were taken from the m.

View Article and Find Full Text PDF

Increases in insulin-mediated glucose uptake following endurance training (ET) and sprint interval training (SIT) have in part been attributed to concomitant increases in glucose transporter 4 (GLUT4) protein content in skeletal muscle. This study used an immunofluorescence microscopy method to investigate changes in subcellular GLUT4 distribution and content following ET and SIT. Percutaneous muscle biopsy samples were taken from the m.

View Article and Find Full Text PDF

Magnetic resonance imaging (MRI) can measure the effects of therapies targeting the tumor vasculature and has demonstrated that vascular-damaging agents (VDA) induce acute vascular shutdown in tumors in human and animal models. However, at subtherapeutic doses, blood flow may recover before the induction of significant levels of necrosis. We present the relationship between changes in MRI biomarkers and tumor necrosis.

View Article and Find Full Text PDF

Purpose: To characterize misregistration artifact in arterial input function (AIF) pixels in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a two-dimensional non-echo-planar imaging (EPI)-based gradient-recalled echo (GRE) sequence.

Materials And Methods: Dynamic gadopentetate-enhanced MRI was acquired in the rat using a semikeyhole acquisition scheme. The AIF was obtained from abdominal aorta pixels.

View Article and Find Full Text PDF

The purpose of this study was to design a keyhole pulse sequence for quantitative 2D dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on a spoiled gradient echo T1-weighted acquisition. Saturation recovery was applied to achieve a linear correlation between signal intensity and contrast agent concentration in an arterial input function (AIF) while simultaneously removing time-of-flight effect. To remove ghosting artifacts arising from incomplete presaturation, EXORCYCLE phase cycling with averaging was applied to the pulse sequence.

View Article and Find Full Text PDF