TRANSIA PLATE Gold is an ELISA that was validated by Association Française de Normalisation (AFNOR) in 2001 and as a (PTM) by AOAC in 2006 (PTM No. 010602) as a two-step enrichment protocol requiring 48 h. A simple next-day enrichment protocol using modified Enterohemorrhagic media was developed for the TRANSIA PLATE Gold to improve the time-to-results and laboratory work flow.
View Article and Find Full Text PDFVIP Gold for is a lateral flow immunodetection device that was validated by AOAC in 1999 as 999.09. It was improved upon in 2009 by introducing gold colloid as the detection method.
View Article and Find Full Text PDFThe TRANSIA PLATE Staphylococcal Enterotoxins enzyme immunoassay (EIA) was validated according to AOAC INTERNATIONAL guidelines for validating qualitative binary chemistry and microbiological methods. Five food matrixes were analyzed to determine the probability of detection (POD) for staphylococcal enterotoxins (SE), including SEA, SEB, SEC, SEC₂, SEC₃, SED, and SEE, by the TRANSIA PLATE Staphylococcal Enterotoxins EIA. The food matrixes tested were food types implicated in staphylococcal enterotoxin outbreaks and included raw milk cheese, liquid infant formula, eclairs, ready-to-eat ham, and canned mushrooms.
View Article and Find Full Text PDFAssurance GDS(®) MPX ID for Top Shiga toxin-producing Escherichia coli (STEC; MPX ID) was validated according to the AOAC INTERNATIONAL Methods Committee Guidelines for Validation of Microbiological Methods for Foods and Environmental Surfaces as (1) a secondary screening method for specific detection of the Top 6 STEC serogroups (O26, O45, O103, O111, O121, and O145) in raw beef trim, raw ground beef, raw spinach, and on stainless steel; and (2) as a confirmatory method for the identification of pure culture isolates as Top 6 STEC. MPX ID is used in conjunction with the upfront BCS Assurance GDS MPX Top 7 STEC assay. This Performance Tested Method(SM) validation has two main parts: Method Developer studies and the Independent Laboratory study.
View Article and Find Full Text PDFAssurance GDSTM for Salmonella Tq has been validated according to the AOAC INTERNATIONAL Methods Committee Guidelines for Validation of Microbiological Methods for Food and Environmental Surfaces for the detection of selected foods and environmental surfaces (Official Method of AnalysisSM 2009.03, Performance Tested MethodSM No. 050602).
View Article and Find Full Text PDFThe Assurance GDS Shiga Toxin Genes (0157), AOAC Official MethodsM 2005.05, has been modified to include a larger sample size of 375 g. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method.
View Article and Find Full Text PDFThe Assurance GDS Escherichia coli (E. col) O157:H7, AOAC Official Method 2005.04, has been modified to include a larger sample size of 375 g.
View Article and Find Full Text PDFA multilaboratory collaborative study was conducted to compare the detection of Salmonella by the Assurance GDS for Salmonella method and the Reference culture methods. Six foods, representing a variety of low microbial and high microbial load foods were analyzed. Seventeen laboratories in the United States and Canada participated in this study.
View Article and Find Full Text PDFA study was conducted to determine the efficacy of detecting low contamination levels of Salmonella in peanut butter using TRANSIA PLATE Salmonella Gold (TPSG). This study was conducted under the AOAC Emergency Response Validation program. A set of samples was each analyzed by the TPSG method and the U.
View Article and Find Full Text PDFA study was conducted to determine the efficacy of detecting low contamination levels of Salmonella in peanut butter using the 1-2 Test. This study was conducted under the AOAC Research Institute Emergency Response Validation program. A set of samples was analyzed by the 1-2 Test and the U.
View Article and Find Full Text PDFThe Visual Immunoprecipitate (VIP) for the Detection of Salmonella in Foods, AOAC Official Method 999.09, has been modified to change the color of the test and control lines of the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method.
View Article and Find Full Text PDFThe Visual Immunoprecipitate (VIP) for the Detection of Listeria in Foods and Environmental Surfaces, AOAC Official Method 997.03, has been modified to change the color of the test and control lines of the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method.
View Article and Find Full Text PDFThe Visual Immunoprecipitate (VIP) for the Detection of Escherichia coli 0157:H7 in Foods, AOAC Official Method 996.09, has been modified to change the color of the test and control lines of the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method.
View Article and Find Full Text PDFThe Visual Immunoprecipitate (VIP) for the Detection of Salmonella in Foods, AOAC Official Method 999.09, has been modified to use a simplified housing for the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method.
View Article and Find Full Text PDFThe Visual Immunoprecipitate (VIP) for the Detection of Listeria in Foods and Environmental Surfaces, AOAC Official Method 997.03, has been modified to use a simplified housing for the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture methods.
View Article and Find Full Text PDFThe Visual Immunoprecipitate (VIP) for the Detection of E. coli O157:H7 in Foods, AOAC Official Method 996.09, has been modified to use a simplified plastic housing for the device.
View Article and Find Full Text PDFThe Assurance Enzyme Immunoassay (EIA) for the Detection of Listeria in Foods and Environmental Surfaces, AOAC Official Method 996.14, has been modified to combine the separate antibody and conjugate addition steps into one. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture methods.
View Article and Find Full Text PDFA multilaboratory collaborative study was conducted to compare the Assurance GDS for E. coli 0157:H7 method and the reference culture methods for the detection of E. coli 0157:H7 in orange juice, raw ground beef, and fresh lettuce.
View Article and Find Full Text PDFThe relative effectiveness of the SimPlate Coliform and E. coli Color Indicator (CEc-CI) method was compared to the AOAC 3-tube Most Probable Number (MPN) methods for enumerating and confirming coliforms and Escherichia coli in foods (966.23 and 966.
View Article and Find Full Text PDFThe Visual Immunoprecipitate Assay (VIP) method for the detection of enterohemorrhagic Escherichia coli O157:H7 (VIP for EHEC) and Assurance Enzyme Immunoassay (EIA) method for the detection of EHEC (EHEC EIA) are AOAC INTERNATIONAL Official Methods 996.09 and 996.10, respectively.
View Article and Find Full Text PDFThe relative effectiveness of the SimPlate Yeast and Mold-Color Indicator method (Y&M-CI) was compared to the U.S. Food and Drug Administration's (FDA) Bacteriological Analytical Manual (BAM) method and the proposed International Organization for Standardization (ISO) method, ISO/CD 21527, for enumerating yeasts and molds in foods.
View Article and Find Full Text PDFThree food types were analyzed for the presence of Salmonella by the AOAC culture method and by the International Organization for Standardization (ISO 6579:2002) culture method. Paired test portions of each food type were simultaneously analyzed by both methods. A total of 21 laboratories representing federal government agencies and private industry, in the United States and Europe, participated in this interlaboratory study.
View Article and Find Full Text PDFThe relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C).
View Article and Find Full Text PDFResponding to a need for a guide for conducting Official Method validation studies of microbiological methods, AOAC utilized the experience of three microbiologists who have been active in the field of method validation. In collaboration, a document was prepared which covered the following areas: terms and their definitions associated with the Official Methods program (e.g.
View Article and Find Full Text PDFAOAC Official Method 996.10, Assurance Enzyme Immunoassay (EIA) for Escherichia coli O157:H7 (EHEC), was modified to incorporate a new enrichment protocol using BioControl EHEC8 medium for testing raw and cooked beef. Foods were tested by EIA and the U.
View Article and Find Full Text PDF