Aim: Complete arthrocentesis of the effusive knee ameliorates patient pain, reduces intra-articular and intraosseous pressure, removes inflammatory cytokines, and has been shown to substantially improve the therapeutic outcomes of intra-articular injections. However, conventional arthrocentesis incompletely decompresses the knee, leaving considerable residual synovial fluid in the intra-articular space. The present study determined whether external pneumatic circumferential compression of the effusive knee permitted more successful arthrocentesis and complete joint decompression.
View Article and Find Full Text PDFIntroduction/objectives: We hypothesized that mechanical compression of the knee in rheumatoid arthritis (RA) would mobilize occult extractable fluid and improve arthrocentesis success.
Methods: Sixty-seven consecutive knees with RA and 186 knees with OA and were included. Conventional arthrocentesis was performed and success and volume (milliliters) determined; the needle was left intraarticularly, and mechanical compression was applied with an elastomeric knee brace.
Orthop Clin North Am
October 2018
Technologies continue to shape the path of medical treatment. Orthopedic surgeons benefit from becoming more aware of how twenty-first century information technology (IT) can benefit patients. The percentage of orthopedic patients utilizing IT resources is increasing, and new IT tools are becoming utilized.
View Article and Find Full Text PDFBackground/objective: The objective of this study was to determine whether the extended or flexed knee positioning was superior for arthrocentesis and whether the flexed knee positioning could be improved by mechanical compression.
Methods: Fifty-five clinically effusive knees underwent arthrocentesis in a quality improvement intervention: 20 consecutive knees in the extended knee position using the superolateral approach, followed by 35 consecutive knees in the flexed knee position with and without an external compression brace placed on the suprapatellar bursa. Arthrocentesis success and fluid yield in milliliters were measured.
We hypothesized that constant compression of the knee would mobilize residual synovial fluid and promote successful arthrocentesis. Two hundred and ten knees with grade II-III osteoarthritis were included in this paired design study: (1) conventional arthrocentesis was performed with manual compression and success and volume (milliliters) determined; and (2) the intra-articular needle was left in place, and a circumferential elastomeric brace was tightened on the knee to provide constant compression. Arthrocentesis was attempted again and additional fluid volume was determined.
View Article and Find Full Text PDFBotulinum neurotoxin (BoNT) binds to and internalizes its light chain into presynaptic compartments with exquisite specificity. While the native toxin is extremely lethal, bioengineering of BoNT has the potential to eliminate toxicity without disrupting neuron-specific targeting, thereby creating a molecular vehicle capable of delivering therapeutic cargo into the neuronal cytosol. Building upon previous work, we have developed an atoxic derivative (ad) of BoNT/C1 through rationally designed amino acid substitutions in the metalloprotease domain of wild type (wt) BoNT/C1.
View Article and Find Full Text PDFCyto-012 is a recombinant derivative of Botulinum neurotoxin Type A (BoNT/A). It primarily differs from wild type (wt) BoNT/A1 in that it incorporates two amino acid substitutions in the catalytic domain of the light chain (LC) metalloprotease (E224 > A and Y366 > A), designed to provide a safer clinical profile. Cyto-012 is specifically internalized into rat cortical and hippocampal neurons, and cleaves Synaptosomal-Associated Protein 25 (SNAP-25), the substrate of wt BoNT/A, but exhibits slower cleavage kinetics and therefore requires a higher absolute dose to exhibit pharmacologic activity.
View Article and Find Full Text PDFBackground: Preoperative risk stratification and optimization of preoperative care may be helpful in reducing readmission rates after primary total joint arthroplasty. Assessment of the predictive value of individual modifiable risk factors without a tool to assess cumulative risk may not provide proper risk stratification of patients with regard to potential readmissions. As part of a Perioperative Orthopaedic Surgical Home model, we developed a scoring system, the Readmission Risk Assessment Tool (RRAT), which allows for risk stratification in patients undergoing elective primary total joint arthroplasty at our institution.
View Article and Find Full Text PDFObjectives: Osteoarthritis of the knee is a chronic disease associated with pain and reduced quality of life. The ability to reliably measure patient-reported symptoms is important for clinical decision making and evaluation of outcomes. Electronic and web-based tools can eliminate much of the labor-intensive aspects of questionnaire administration and enables both real-time evaluation of responses by physicians and integration of data from multiple sites.
View Article and Find Full Text PDFBackground: Greater levels of self-reported pain, pain catastrophizing, and depression have been shown to be associated with persistent pain and functional limitation after surgeries such as TKA. It would be useful for clinicians to be able to measure these factors efficiently.
Questions/purposes: We asked: (1) What is the association of whole-body pain with osteoarthritis (OA)-related knee pain, function, pain catastrophizing, and mental health? (2) What is the sensitivity and specificity for different cutoffs for body pain diagram region categories in relation to pain catastrophizing?
Methods: Patients (n = 267) with knee OA undergoing elective TKA at one academic center and two community orthopaedic centers were enrolled before surgery in a prospective cohort study.
The Centers for Medicare & Medicaid Services considers readmissions within 30 days of discharge to be a quality indicator. Hospitals' and eventually physicians' readmission rates will be used to determine payment for services. It is imperative that health care providers understand which patients are at risk for readmission so that they can apply the appropriate preventive interventions.
View Article and Find Full Text PDFWe have previously described genetic constructs and expression systems that enable facile production of recombinant derivatives of botulinum neurotoxins (BoNTs) that retain the structural and trafficking properties of wt BoNTs. In this report we describe the properties of one such derivative, BoNT/A ad, which was rendered atoxic by introducing two amino acid mutations to the light chain (LC) of wt BoNT/A, and which is being developed as a molecular vehicle for delivering drugs to the neuronal cytoplasm. The neuronal binding, internalization, and intracellular trafficking of BoNT/A ad in primary hippocampal cultures was evaluated using three complimentary techniques: flow cytometry, immunohistochemistry, and Western blotting.
View Article and Find Full Text PDFJ Am Acad Orthop Surg
June 2013
Researchers and clinicians operate in an increasingly complex clinical and regulatory environment in which understanding the principles governing human research is essential. However, most orthopaedic surgeons have not received in-depth training in regulatory requirements and scientific research methods. Ensuring that research is conducted in accordance with state and federal laws and ethical principles is essential to guard compromising patient information and avoid severe penalties for noncompliance.
View Article and Find Full Text PDFObjective: The present randomized controlled study investigated whether sonographic needle guidance affected the outcomes of intra-articular injection for osteoarthritis of the knee.
Methods: Ninety-four noneffusive knees with osteoarthritis were randomized to injection by conventional palpation-guided anatomic landmark injection or sonographic image-guided injection enhanced with a 1-handed mechanical (the reciprocating procedure device) syringe. After intra-articular placement and synovial space dilation were confirmed by sonography, a syringe exchange was performed, and 80 mg of triamcinolone acetonide was injected with the second syringe through the indwelling intra-articular needle.
J Bone Joint Surg Am
September 2011
Background: The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures.
Methods: The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe).
Sports Med Arthrosc Rehabil Ther Technol
March 2011
Background: The extended knee lateral midpatellar portal for intraarticular injection of the knee is accurate but is not practical for all patients. We hypothesized that a modified anteriolateral portal where the synovial membrane of the medial femoral condyle is the target would be highly accurate and effective for intraarticular injection of the knee.
Methods: 83 subjects with non-effusive osteoarthritis of the knee were randomized to intraarticular injection using the modified anteriolateral bent knee versus the standard lateral midpatellar portal.
Non-toxic derivatives of botulinum neurotoxin A (BoNT/A) have potential use as neuron-targeting delivery vehicles, and as reagents to study intracellular trafficking. We have designed and expressed an atoxic derivative of BoNT/A (BoNT/A ad) as a full-length 150 kDa molecule consisting of a 50 kDa light chain (LC) and a 100 kDa heavy chain (HC) joined by a disulfide bond and rendered atoxic through the introduction of metalloprotease-inactivating point mutations in the light chain. Studies in neuronal cultures demonstrated that BoNT/A ad cannot cleave synaptosomal-associated protein 25 (SNAP25), the substrate of wt BoNT/A, and that it effectively competes with wt BoNT/A for binding to endogenous neuronal receptors.
View Article and Find Full Text PDFAlthough intraarticular injections are important to the management of rheumatoid arthritis, there are few studies regarding the cost-effectiveness of alternative injection techniques. This randomized controlled study addressed the cost-effectiveness of two different low-cost, anatomic landmark palpation-directed intraarticular injection techniques. Ninety-six symptomatic rheumatoid knees were randomized to two different low-cost, palpation-guided intraarticular injection techniques utilizing (1) a conventional syringe or (2) a mechanical syringe, the RPD (the reciprocating procedure device).
View Article and Find Full Text PDFObjective: We studied whether sonographic needle guidance affected the outcomes of intraarticular (IA) injection for inflammatory arthritis.
Methods: Joints with inflammatory arthritis (n = 244; 76% rheumatoid arthritis, 3% small joints, 51% intermediate, and 46% large) were randomized to injection by conventional palpation-guided anatomic injection (120 joints) or sonographic image-guided injection enhanced with a 1-handed reciprocating procedure device mechanical syringe (124 joints). A 1-needle, 2-syringe technique was used.
Work from multiple laboratories has clarified how the structural domains of botulinum neurotoxin A (BoNT/A) disable neuronal exocytosis, but important questions remain unanswered. Because BoNT/A intoxication disables its own uptake, light chain (LC) does not accumulate in neurons at detectable levels. We have therefore designed, expressed and purified a series of BoNT/A atoxic derivatives (ad) that retain the wild type features required for native trafficking.
View Article and Find Full Text PDFObjective: This randomized controlled study addressed whether sonographic needle guidance affected clinical outcomes of intraarticular (IA) joint injections.
Methods: In total, 148 painful joints were randomized to IA triamcinolone acetonide injection by conventional palpation-guided anatomic injection or sonographic image-guided injection enhanced with a one-handed control syringe (the reciprocating device). A one-needle, 2-syringe technique was used, where the first syringe was used to introduce the needle, aspirate any effusion, and anesthetize and dilate the IA space with lidocaine.
Inter-alpha-inhibitor, TSG-6, and hyaluronan have important functions in fertility and inflammation. Two subunits of inter-alpha-inhibitor, the heavy chains, form covalent bonds with TSG-6 or hyaluronan in vitro. TSG-6-heavy chain complexes serve as intermediates in the transfer of heavy chains from inter-alpha-inhibitor to hyaluronan.
View Article and Find Full Text PDF