Publications by authors named "Peutzfeldt A"

Objectives: To assess the degree of tooth wear in children and adolescents by application of a qualitative wear index and by quantitative measurement on digital models. The hypothesis was that the quantitative method would be sensitive to reliably measure tooth wear.

Methods: Existing digital models (n = 24) gathered from a prospective clinical study were analysed.

View Article and Find Full Text PDF

Purpose: To assess the manufacturing accuracy, intaglio surface adaptation, and survival of resin-based CAD/CAM definitive crowns created via additive manufacturing (AM) or subtractive manufacturing (SM).

Materials And Methods: A maxillary right first molar crown was digitally designed and manufactured using AM hybrid resin composite (VarseoSmile Crown Plus, Bego [AM-HRC]), AM glass filler-reinforced resin composite (Crowntec, Saremco Dental [AM-RC]), and SM polymer-infiltrated ceramic (Vita Enamic, VITA Zahnfabrik [SM-PICN]). Manufacturing accuracy (trueness and precision) was assessed by computing the root mean square (RMS) error (in μm; n = 15 per material).

View Article and Find Full Text PDF

Objective: To evaluate how restorative material, resin cement, and cyclic loading affect the fracture resistance of resin-based crowns fabricated by using additive or subtractive manufacturing.

Methods: A right first molar crown standard tessellation language (STL) file was used to fabricate 120 crowns from one subtractively manufactured polymer-infiltrated ceramic network (SM) and two additively manufactured resin composites (AM-B and AM-S) (N = 40). These crowns were randomly divided into 4 groups within each material according to the dual-polymerizing resin cement to be used (RX and PN) and the aging condition (n = 10).

View Article and Find Full Text PDF

Objectives: Due to innumerable confounding factors and a high number of types and brands of dental restorative materials, the clinical performance of restorative materials are sought predicted by various in vitro tests. However, only few such tests have been found to correlate well with clinical findings. Thus, the present study determined the in vitro dentin bond strength and marginal adaptation of Class II restorations and correlated the results to their clinical outcomes.

View Article and Find Full Text PDF

The aim of this study was to compare the assessment of tooth wear performed on digital models with the one conducted at the clinical examination. Seventy-eight volunteers (29 males and 49 females, age range 20-30 years) with at least 24 teeth, normal oral function, and a neutral transverse relationship were examined. During the clinical examination, dental wear was registered according to the Basic Erosive Wear Examination (BEWE) index.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of polishing and denture cleansers on the surface roughness (R) of new-generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing.

Material And Methods: One hundred and fifty disk-shaped specimens (Ø10 × 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene-reinforced prepolymerized polymethylmethacrylate (PMMA) (SM-GC), one subtractively manufactured prepolymerized PMMA (SM-PM), two additively manufactured denture base resins (AM-DT and AM-ND), and one heat-polymerized PMMA (CV) (n = 30). The R of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing.

View Article and Find Full Text PDF

Statement Of Problem: Additively manufactured composite resins for definitive restorations have been recently introduced. The bond strength between these composite resins and different substrates has not been extensively studied.

Purpose: The purpose of this in vitro study was to measure the shear bond strength (SBS) between additively manufactured composite resins and dentin and titanium substrates and compare those with the SBS between subtractively manufactured polymer-infiltrated ceramic and the same substrates (dentin and titanium), when different dual-polymerizing resin cements were used.

View Article and Find Full Text PDF

: To investigate the impact of adhesive application errors on dentin bond strength of resin composite. : 165 extracted permanent human molars were ground to mid-coronal dentin. The dentin specimens were treated with one of three adhesive systems (OptiBond FL, Clearfil SE, Scotchbond Universal) either according to manufacturer's instructions or with systematic errors in the application procedure and before application of resin composite (Filtek Z250).

View Article and Find Full Text PDF

Adhesion and marginal adaptation of a claimed bioactive restorative material (ACTIVA BioACTIVE Restorative) to human teeth were compared with those of a resin-modified glass ionomer cement (Fuji II LC) and a control resin composite (Ceram X Mono). Shear bond strength and marginal adaptation to enamel and dentine were assessed after no pretreatment of the hard tissues or after etching with phosphoric acid (ACTIVA BioACTIVE Restorative and Ceram X Mono) or polyacrylic acid (Fuji II LC). For ACTIVA BioACTIVE Restorative, the effect of applying a self-etch adhesive (Xeno Select, Dentsply Sirona) was also investigated.

View Article and Find Full Text PDF

Objectives: To investigate short- and long-term bond strength ("repair bond strength"; RBS) of a resin composite to six restorative materials using either a silane and a bonding agent or a universal "one-step self-etch" adhesive system.

Methods: Specimens were produced from an amalgam, a direct resin composite, two indirect resin composites, a hybrid ceramic, and a feldspar ceramic and stored for 3 months in tap water (37 °C). All specimens were then sandblasted (AlO; 25 μm) and either treated with Monobond Plus and OptiBond FL Adhesive (MP-OFL) or with Scotchbond Universal (SBU).

View Article and Find Full Text PDF

This study investigated the effect of SnCl/AmF pretreatment on short- and long-term bond strength of resin composite to eroded dentin mediated by two self-etch, MDP-containing adhesive systems. 184 dentin specimens were produced from extracted human molars. Half the specimens ( = 92) were artificially eroded, and half were left untreated.

View Article and Find Full Text PDF

Objective: To investigate the relationship between physicochemical interactions of resin luting cements with dentine and retention of fibre posts in root canals.

Methods: Retention of fibre posts (RelyX Fiber Post) was assessed by the pull-out method. The diffusion zone of the cements and their chemical interaction with dentine were estimated by micro-Raman spectroscopy.

View Article and Find Full Text PDF

The aim of this in vitro study was to investigate the marginal gap formation of a packable "regular" resin composite (Filtek Supreme XTE [3M ESPE]) and two flowable "bulk fill" resin composites (Filtek Bulk Fill [3M ESPE] and SDR [DENTSPLY DeTrey]) along the approximal margins of Class II restorations. In each of 39 extracted human molars (n=13 per resin composite), mesial and distal Class II cavities were prepared, placing the gingival margins below the cemento-enamel junction. The cavities were restored with the adhesive system OptiBond FL (Kerr) and one of the three resin composites.

View Article and Find Full Text PDF

This study investigated the effect of benzalkonium chloride (BAC) modification of two adhesive systems on long-term bond strength to normal and artificially eroded dentin. A total of 128 extracted human molars were sectioned and the buccal and oral surfaces of each molar were ground until the dentin. One half was left untreated (normal dentin) while the other half underwent artificial erosion.

View Article and Find Full Text PDF

Purpose: To investigate the effect of relative humidity and saliva contamination on short- and long-term bond strength of two self-etch adhesives to normal and artificially eroded dentin.

Materials And Methods: A total of 480 dentin specimens were produced from extracted human molars. Half of the specimens (n = 240) were left untreated (normal dentin) whereas the other half (n = 240) were artificially eroded.

View Article and Find Full Text PDF

Purpose: To compare various pre-treatments serving as cleaning procedures of dentin on the bond strength of resin composite promoted by a universal adhesive system applied either in the absence or presence of simulated pulpal pressure.

Materials And Methods: Prior to application of the adhesive system (Scotchbond Universal) and resin composite (Filtek Z250), ground dentin surfaces were given one of five pre-treatments either without or with simulated pulpal pressure: 1) no pre-treatment, adhesive system in "self-etch" mode, 2) phosphoric acid etching, adhesive system in "total-etch" mode, 3) polishing with pumice on prophylaxis cup, 4) air abrasion with AIR-FLOW PLUS powder, 5) air abrasion with AIR-FLOW PERIO powder; n = 20/group of pre-treatment. After storage (37°C, 100% humidity, 24 h), micro shear bond strength was measured and data analyzed with parametric ANOVA including Bonferroni-Holm correction for multiple testing followed by Student's t tests (significance level: α = 0.

View Article and Find Full Text PDF

This study investigated the influence of light-curing at high irradiances on micromechanical properties of resin cements. Three dual-curing resin cements and a light-curing flowable resin composite were light-cured with an LED curing unit in Standard mode (SM), High Power mode (HPM), or Xtra Power mode (XPM). Maximum irradiances were determined using a MARC PS radiometer, and exposure duration was varied to obtain two or three levels of radiant exposure (SM: 13.

View Article and Find Full Text PDF

Statement Of Problem: Because of the different composition of resin-ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) materials, their polishability and their micromechanical properties vary. Moreover, depending on the composition of the materials, their surface roughness and micromechanical properties are likely to change with time.

Purpose: The purpose of this in vitro study was to investigate the effect of artificial toothbrushing and water storage on the surface roughness (Ra and Rz) and the micromechanical properties, surface hardness (Vickers [VHN]) and indentation modulus (E), of 5 different tooth-colored CAD-CAM materials when polished with 2 different polishing systems.

View Article and Find Full Text PDF

The aim was to investigate dentin bond strength of two resin-ceramic materials and five cements after 24 h and six months storage. Cylinders (n=15/group) of Lava Ultimate (3M ESPE) and VITA ENAMIC (VITA Zahnfabrik) were cemented to mid-coronal dentin of 300 extracted human molars with RelyX Ultimate (3M ESPE), PANAVIA F2.0 (Kuraray), Variolink II (Ivoclar Vivadent), els cem (Saremco Dental), or Ketac Cem Plus (3M ESPE).

View Article and Find Full Text PDF

Purpose: To investigate the effect of airborne-particle abrasion or diamond bur preparation as pre-treatment steps of non-carious cervical root dentin regarding substance loss and bond strength.

Methods: 45 dentin specimens-produced from crowns of extracted human incisors by grinding the labial surfaces with silicon carbide papers (control) were treated with one of three adhesive systems (Group 1A-C; A: OptiBond FL, B: Clearfil SE Bond, or C: Scotchbond Universal; n= 15/adhesive system). Another 135 dentin specimens (n = 15/group) produced from the labial, non-carious cervical root part of extracted human incisors were treated with one of the adhesive systems after either no pre-treatment (Group 2A-C), pre-treatment with airborne-particle abrasion (CoJet Prep and 50 µm aluminum oxide powder; Group 3A-C), or pre-treatment with diamond bur preparation (40 µm grit size; Group 4A-C).

View Article and Find Full Text PDF

Purpose: To investigate the influence of relative humidity and application time on bond strength to dentin of different classes of adhesive systems.

Materials And Methods: A total of 360 extracted human molars were ground to mid-coronal dentin. The dentin specimens were treated with one of six adhesive systems (Syntac Classic, OptiBond FL, Clearfil SE Bond, AdheSE, Xeno Select, or Scotchbond Universal), and resin composite (Filtek Z250) was applied to the treated dentin surface under four experimental conditions (45% relative humidity/application time according to manufacturers' instructions; 45% relative humidity/reduced application time; 85% relative humidity/application time according to manufacturers' instructions; 85% relative humidity/reduced application time).

View Article and Find Full Text PDF